There is also a wide selection of different I/O and communications options. In addition to these there is a
selection of external accessories available. To optimise the use of the cabinet space, most of the ACS800-04 modules can be
mounted side by side. The modules themselves are not only designed for cabinet assembly, but covering documentation is also
available. This documentation provides examples of different cabinet installations and circuit drawings, and hints on the
selection of auxiliary equipment.
| Type code |
I max Amps |
Nominal Ratings |
Frame Size |
| Normal Duty (CT) (110% I2n) |
Heavy Duty (CT) (150% I2hd) |
| I 2N A |
PN Hp |
I 2HD A |
P HD Hp |
| 240Vac 3-phase supply voltage 208, 220, 230, 240. The power ratings are valid at nominal voltage 240Vac 60Hz |
| ACS800-U4-0001-2+P901 |
6.5 |
4.7 |
1 |
3.5 |
0.75 |
R2 |
| ACS800-U4-0002-2+P901 |
8.2 |
6.6 |
1.5 |
4.6 |
1 |
R2 |
| ACS800-U4-0003-2+P901 |
10.8 |
8.1 |
2 |
6.6 |
1.5 |
R2 |
| ACS800-U4-0004-2+P901 |
13.8 |
11 |
3 |
7.5 |
2 |
R2 |
| ACS800-U4-0006-2+P901 |
24 |
21 |
5 |
13 |
3 |
R3 |
| ACS800-U4-0009-2+P901 |
32 |
27 |
7.5 |
17 |
5 |
R3 |
| ACS800-U4-0011-2+P901 |
46 |
34 |
10 |
25 |
7.5 |
R3 |
| ACS800-U4-0016-2+P901 |
62 |
42 |
15 |
31 |
10 |
R4 |
| ACS800-U4-0020-2+P901 |
72 |
54 |
20(1) |
42 |
15(2) |
R4 |
| ACS800-U4-0025-2+P901 |
86 |
69 |
25 |
54 |
20(2) |
R5 |
| ACS800-U4-0030-2+P901 |
112 |
80 |
30 |
68 |
25(2) |
R5 |
| ACS800-U4-0040-2+P901 |
138 |
104 |
40(1) |
80 |
30(2) |
R5 |
| ACS800-U4-0050-2+P901 |
164 |
132 |
50 |
104 |
40 |
R6 |
| ACS800-U4-0060-2+P901 |
202 |
157 |
60 |
130 |
50(2) |
R6 |
| ACS800-U4-0070-2+P901 |
282 |
192 |
75 |
154 |
60(2) |
R6 |
| ACS800-U4-0080-2+E210+P901 |
326 |
211 |
75 |
170 |
60 |
R7 |
| ACS800-U4-0100-2+E210+P901 |
404 |
248 |
100 |
202 |
75 |
R7 |
| ACS800-U4-0120-2+E210+P901 |
432 |
290 |
100 |
240 |
75 |
R7 |
| ACS800-U4-0140-2+E210+P901 |
588 |
396 |
150 |
316 |
125 |
R8 |
| ACS800-U4-0170-2+E210+P901 |
588 |
440 |
150 |
340 |
125 |
R8 |
| ACS800-U4-0210-2+E210+P901 |
588 |
516 |
200 |
370 |
150 |
R8 |
| ACS800-U4-0230-2+E210+P901 |
840 |
598 |
200 |
480 |
200 |
R8 |
| ACS800-U4-0260-2+E210+P901 |
1017 |
679 |
250 |
590(2) |
200 |
R8 |
| ACS800-U4-0300-2+E210+P901 |
1017 |
704 |
250 |
635(2) |
200 |
R8 |
(1) Rating not applicable for all motors. Available for 4-pole 460V high efficiency NEMA motors.
(2) 50% overload is allowed if ambient temperature is 30°C or less, Overload is limited to 40% at 40°C.
|
| Type code |
I max Amps |
Nominal Ratings |
Frame Size |
| Normal Duty (CT) (110% I2n) |
Heavy Duty (CT) (150% I2hd) |
| I 2N A |
PN Hp |
I 2HD A |
P HD Hp |
| 400Vac 3-phase supply voltage 380, 400, 415. The power ratings are valid at nominal voltage 400Vac 50Hz |
| ACS800-U4-0004-5+P901 |
6.5 |
4.5 |
1.5 |
3.4 |
1.1 |
R2 |
| ACS800-U4-0005-5+P901 |
8.2 |
5.6 |
2.2 |
4.2 |
1.5 |
R2 |
| ACS800-U4-0006-5+P901 |
10.8 |
7.7 |
3 |
5.6 |
2.2 |
R2 |
| ACS800-U4-0009-5+P901 |
13.8 |
10 |
4 |
7.5 |
3 |
R2 |
| ACS800-U4-0011-5+P901 |
17.6 |
12 |
5.5 |
9.2 |
4 |
R2 |
| ACS800-U4-0016-5+P901 |
24 |
18 |
7.5 |
13 |
5.5 |
R3 |
| ACS800-U4-0020-5+P901 |
32 |
23 |
11 |
18 |
7.5 |
R3 |
| ACS800-U4-0025-5+P901 |
46 |
31 |
15 |
23 |
11 |
R3 |
| ACS800-U4-0030-5+P901 |
62 |
39 |
18.5 |
32 |
15 |
R4 |
| ACS800-U4-0040-5+P901 |
72 |
44 |
22 |
36 |
18.5 |
R4 |
| ACS800-U4-0050-5+P901 |
86 |
61 |
30 |
50 |
22 |
R5 |
| ACS800-U4-0060-5+P901 |
112 |
75 |
37 |
60 |
30 |
R5 |
| ACS800-U4-0070-5+P901 |
138 |
88 |
45 |
69 |
37 |
R5 |
| ACS800-U4-0100-5+P901 |
164 |
115 |
55 |
88 |
45 |
R6 |
| ACS800-U4-0120-5+P901 |
202 |
145 |
75 |
113 |
55 |
R6 |
| ACS800-U4-0140-5+P901 |
282 |
163 |
90 |
141 |
75 |
R6 |
| ACS800-U4-0205-5+P901 |
326 |
254 |
132 |
215 |
90 |
R6 |
| ACS800-U4-0170-5+E210+P901 |
326 |
192 |
90 |
162 |
90 |
R7 |
| ACS800-U4-0210-5+E210+P901 |
384 |
240 |
132 |
192 |
90 |
R7 |
| ACS800-U4-0260-5+E210+P901 |
432 |
284 |
160 |
224 |
110 |
R7 |
| ACS800-U4-0320-5+E210+P901 |
588 |
435 |
200 |
340 |
160 |
R8 |
| ACS800-U4-0400-5+E210+P901 |
588 |
510 |
250 |
370 |
200 |
R8 |
| ACS800-U4-0440-5+E210+P901 |
840 |
545 |
315 |
490 |
250 |
R8 |
| ACS800-U4-0490-5+E210+P901 |
840 |
590 |
315 |
515(2) |
250 |
R8 |
| ACS800-U4-0610-5+E210+P901 |
1017 |
704 |
400 |
632(2) |
355 |
R8 |
|
(2) 50% overload is allowed if ambient temperature is 30°C or less, Overload is limited to 40% at 40°C.
|
| Type code |
I max Amps |
Nominal Ratings |
Frame Size |
| Normal Duty (CT) (110% I2n) |
Heavy Duty (CT) (150% I2hd) |
| I 2N A |
PN Hp |
I 2HD A |
P HD Hp |
| 480Vac 3-phase supply voltage 380, 400, 415, 460, 480, 500. The power ratings are valid at nominal voltage 480Vac 60Hz |
| ACS800-U4-0004-5+P901 |
6.5 |
4.9 |
3 |
3.4 |
2 |
R2 |
| ACS800-U4-0005-5+P901 |
8.2 |
6.2 |
3 |
4.2 |
2 |
R2 |
| ACS800-U4-0006-5+P901 |
10.8 |
8.1 |
5 |
5.6 |
3 |
R2 |
| ACS800-U4-0009-5+P901 |
13.8 |
11 |
7.5 |
8.1 |
5 |
R2 |
| ACS800-U4-0011-5+P901 |
17.6 |
14 |
10 |
11 |
7.5 |
R2 |
| ACS800-U4-0016-5+P901 |
24 |
21 |
15 |
15 |
10 |
R3 |
| ACS800-U4-0020-5+P901 |
32 |
27 |
20 |
21 |
15 |
R3 |
| ACS800-U4-0025-5+P901 |
46 |
34 |
25 |
27 |
20 |
R3 |
| ACS800-U4-0030-5+P901 |
62 |
42 |
30 |
34 |
25 |
R4 |
| ACS800-U4-0040-5+P901 |
72 |
52 |
40 |
37 |
30(3) |
R4 |
| ACS800-U4-0050-5+P901 |
86 |
65 |
50 |
52 |
40 |
R5 |
| ACS800-U4-0060-5+P901 |
112 |
79 |
60 |
65 |
50 |
R5 |
| ACS800-U4-0070-5+P901 |
138 |
96 |
75 |
77 |
60 |
R5 |
| ACS800-U4-0100-5+P901 |
164 |
124 |
100 |
96 |
75 |
R6 |
| ACS800-U4-0120-5+P901 |
202 |
157 |
125 |
124 |
100 |
R6 |
| ACS800-U4-0140-5+P901 |
282 |
180 |
150 |
156 |
125 |
R6 |
| ACS800-U4-0205-5+P901 |
326 |
254 |
200 |
215 |
150 |
R6 |
| ACS800-U4-0170-5+E210+P901 |
326 |
192 |
150 |
162 |
125 |
R7 |
| ACS800-U4-0210-5+E210+P901 |
384 |
240 |
200 |
192 |
150 |
R7 |
| ACS800-U4-0260-5+E210+P901 |
432 |
286 |
200(*) |
224 |
150 |
R7 |
| ACS800-U4-0270-5+E210+P901 |
480 |
316 |
250 |
240 |
200 |
R8 |
| ACS800-U4-0300-5+E210+P901 |
568 |
361 |
300 |
302 |
250 |
R8 |
| ACS800-U4-0320-5+E210+P901 |
588 |
435 |
350 |
340 |
250 |
R8 |
| ACS800-U4-0400-5+E210+P901 |
588 |
510 |
400 |
370 |
300 |
R8 |
| ACS800-U4-0440-5+E210+P901 |
840 |
545 |
450 |
490 |
400 |
R8 |
| ACS800-U4-0490-5+E210+P901 |
840 |
590 |
500 |
515(2) |
450 |
R8 |
| ACS800-U4-0550-5+E210+P901 |
1017 |
670 |
550 |
590(2) |
500 |
R8 |
| ACS800-U4-0610-5+E210+P901 |
1017 |
704 |
600(1) |
590(2) |
500 |
R8 |
* rating of 250Hp may be available on some high efficiency 4 pole 460v NEMA motors
(2) 50% overload is allowed if ambient temperature is 30°C or less, Overload is limited to 40% at 40°C.
(3) The higher rating is available when output frequency is above 41 Hz.
|
| Type code |
I max Amps |
Nominal Ratings |
Frame Size |
| Normal Duty (CT) (110% I2n) |
Heavy Duty (CT) (150% I2hd) |
| I 2N A |
PN Hp |
I 2HD A |
P HD Hp |
| 600Vac 3-phase supply voltage 525, 550, 575, 600, 690. The power ratings are valid at nominal voltage 575Vac 60Hz |
| ACS800-04-0011-7+P901 |
14 |
11.5 |
10 |
8.5 |
5 |
R4 |
| ACS800-04-0016-7+P901 |
19 |
15 |
10 |
11 |
10 |
R4 |
| ACS800-04-0020-7+P901 |
28 |
20 |
15 |
15 |
10 |
R4 |
| ACS800-04-0025-7+P901 |
38 |
23 |
20 |
19 |
15 |
R4 |
| ACS800-04-0030-7+P901 |
44 |
30 |
25 |
22 |
20 |
R4 |
| ACS800-04-0040-7+P901 |
54 |
34 |
30 |
27 |
25 |
R4 |
| ACS800-04-0050-7+P901 |
68 |
46 |
40 |
34 |
30 |
R5 |
| ACS800-04-0060-7+P901 |
84 |
52 |
50 |
42 |
40 |
R5 |
| ACS800-04-0070-7+P901 |
104 |
73 |
60 |
54 |
50 |
R6 |
| ACS800-04-0100-7+P901 |
124 |
86 |
75 |
62 |
60 |
R6 |
| ACS800-04-0120-7+P901 |
172 |
108 |
100 |
86 |
75 |
R6 |
| ACS800-04-0145-7+P901 |
245 |
125 |
125 |
99 |
100 |
R6 |
| ACS800-04-0175-7+P901 |
245 |
155 |
150 |
131 |
125 |
R6 |
| ACS800-04-0205-7+P901 |
245 |
192 |
200 |
147 |
150 |
R6 |
| ACS800-04-0140-7+P901 |
190 |
125 |
125 |
95 |
100(1) |
R7 |
| ACS800-04-0170-7+P901 |
263 |
155 |
150 |
131 |
125 |
R7 |
| ACS800-04-0210-7+P901 |
294 |
165 /195(3) |
150 /200(3) |
147 |
150 |
R7 |
| ACS800-04-0260-7+P901 |
326 |
175 /212(3) |
150 /200(3) |
163 |
150 |
R7 |
| ACS800-04-0320-7+E208+P901 |
433 |
290 |
300 |
216 |
200 |
R8 |
| ACS800-04-0400-7+E208+P901 |
548 |
344 |
350 |
274 |
250 |
R8 |
| ACS800-04-0440-7+E208+P901 |
656 |
387 |
400 |
328 |
350(1) |
R8 |
| ACS800-04-0490-7+E208+P901 |
775 |
426 |
450 |
387 |
400 |
R8 |
| ACS800-04-0550-7+E208+P901 |
853 |
482 |
500 |
426 |
450 |
R8 |
| ACS800-04-0610-7+E208+P901 |
964 |
537 |
550 |
482 |
500 |
R8 |
(1) Rating not applicable for all motors. Available for 4-pole 460V high efficiency NEMA motors.
(3) The higher rating is available when output frequency is above 41 Hz.
|
Our industrial factory automation supplies istributors warehouse in Boise, Idaho USA stocks some ABB industrial
ACS800-04 AC drive products enabling us to further assist you in finding the correct ACS800-U4-0001-2+P901 drive in the USA, Canada
and Mexico. Whether we have ACS800-U4-0002-2+P901 drive in stock in Boise, Idaho USA or need to get them from ABB Group; Clearwater
Tech can get ACS800-U4-0004-5+P901 drive to you fast and save you some money! It will be very helpful if you have the
ACS800-U4-0005-5+P901 drive part numbers ready, then our sales representatives can provide you with a pricing and availability quote
for ACS800-U4-0004-5+P901 drive that you are looking for in seconds. If you do not have the part numbers for ACS800-U4-0005-5+P901 drive,
our application engineers will be able to help you figure out the part numbers and get the price quote to you as soon as
possible.