June 17, 2011
NK Transducers
DLT Series
DC current transducers combine a hall effect sensor and a True RMS signal conditioner into a single package. The DLT Series
is designed to produce an analog 4-20 mA signal proportional to the DC current in the primary conductor. Available in a
solid-core or split-core case design. Lower current ranges make this sensor ideal for use in photovoltaic panel combiner
boxes.
|
Vacon Drives
The Vacon 8000 SOLAR
is a vital part of the configuration between the solar panels and the grid: it converts photovoltaic DC power into AC power,
and feeds it into the grid. Vacon's Multimaster software has made it possible to connect one to eight inverter modules, based
on the amount of sunshine, thus ensuring that the glassware factory's solar power plant operates with the best possible
efficiency.
|
|
|
|
 |
(800) 894-0412 (888) 723-4773 (Fax) info@clrwtr.com |
 S284 UC Z & S800PV-S |
The S280 UC Range of miniature circuit breakers
features permanent magnets on the internal arcing chutes able to extinguish an electric arc of up to 484 V DC with Icu =
4.5 kA. However, use of these components establishes circuit-breaker polarity, thus they must be powered in a certain
direction.
S800PV-S miniature circuit-breakers can be used in networks up to 1200 V DC. S800PV-S was specially
designed for use in PV applications as it safely extinguishes dangerous DC arcs even in case of double faults.
|
|
If you are looking for ABB Photovoltaic Products, please call us on
(800) 894 - 0412 or email us at
info@clrwtr.com
we will do our best to help you find the ABB Photovoltaic Miniature Circuit Breakers that you are looking for at the most
competitive prices possible. If you are searching for ABB Low Voltage Photovoltaic Switch Disconnectors technical information
(data-sheets) please use the datasheets or product selection guide page links.
|
 S800PV-M, OT & Tmax PV |
S800PV-M switch-disconnectors can be used in networks up to 1200 V DC S800PV-M was specially designed for
the use in PV applications as it safely switches DC arcs.
Tmax PV series disconnectors are available with up to 1600 A class DC-22B rated operating current values,
for 1100 V DC maximum rated operating voltage. The switching devices of the Tmax PV series are
The First Box Disconnectors for direct current high voltage available on the market.
They are certainly of interest for use in any type of photovoltaic installation since they are ideal for all disconnecting
requirements.
|
 E 90 PV & E 9F PV |
The E 90 PV series fuse disconnectors have been designed for up to 1000 V direct current voltage with
DC-20B utilization category. The E 90 PV series is specifically used for protecting photovoltaic systems against
overcurrents and provides a reliable, compact and inexpensive solution since it uses 10.3 x 38 mm cylindrical fuses. When E
90 PV are installed in battery, blown fuse indicator allows an easy detection of the pole where the blown cartridge must be
replaced. Thanks to the red colored LED on the handle, user can see whether the fuse is working or blown.
E 9F PV range of cylindrical fuses has been specifically designed to protect direct current circuits up
to 1000 V. E 9F PV 10.3 x 38 mm fuses are the best solution for protecting strings, inverters and surge arresters in
photovoltaic systems up to 30 A rated current.
|
 F202 PV B, F204 B, DDA202 B, DDA203 B & DDA204 B |
Residual current devices ensure protection of people and installations against fault current to earth and
fire risks. An RCD B type is required on the AC side in case of lack of electrical separation between the AC and DC side. The
devices save money and improve global efficiency by using PV converters without an internal insulation transformer. The
devices, with their wide range of accessories, are suitable for international use. The RCCBs F202 PV B and F204 B are intended
for installation of mono-and three-phase PV converters. They protect against fire risks and leakage currents.
The RCD-Blocks DDA202 B, DDA203 B and DDA204 B are designed for installations of mono and three-phase PV
converters. In combination with S200 series MCBs, the protection of people and installations against fire risks, leakage and
over current is assured.
|
 CM-UFS |
Even small distributed generating systems need to be connected to the power grid with guarantees as to
completely safe operation, especially when the energy flow towards the network must be shut off for maintenance or if a fault
occurs in the network itself. Rapid disconnection is essential if hazardous situations for the people who must work on the
lines are to be avoided.
This sort of protection can be achieved with an automatic monitoring device able to immediately detect
faults in the network. The CM-UFS interface, which conforms to both the italian ENEL Distribuzione Directive for connections
to the electricity main and to german DIN V VDE 0126-1-1, answers to the need for safety for both the installations and the
operators in the case of faults and malfunctions in the public power grid during parallel operation.
|
 Modular Terminal Blocks |
ABB offers a complete range of Modular Terminals, from the
conventional screw-clamp and spring-clamp terminal blocks to the most technologically advanced self-stripping connection
that, by means of a dedicated tool, enables quick, safe and reliable connection (ADO). More suitable for photovoltaic
applications are screw-clamp or ADO (self-stripping technology) terminal blocks; the latter ensure higher connection
reliability in the long term.
The new innovative and compact ABB terminal blocks SNK Series feature modern design and a lot of
accessories to meet the various needs of the customers; they have certifications recognized worldwide.
|
 ODINsingle |
A compact single phase meter for direct metering up to 65 A. Designed for DIN-rail mounting, where space
is limited. The meter is only 2 modules wide. With a backlit LCD display on the front the measured values are easily
accessible for the reader. If communication is required the meter communicates through IR interface or pulse output.
ODINsingle is available in two order codes, OD1065 or OD1365. The OD1365 has two counters of which one is
resettable. To be used in applications as marinas, camping or other areas where there is a need for revenue metering and
easy resettable counters.
|
 DELTAmax |
DELTAmax has a lot of functionality. The built-in clock function is used to log meter data in a load
profile or control the setting of tariffs. It is easy to read the large LCD display with 7 mm high digits and symbols for
load indication, errors etc. The meter has LED on the front that flashes proportionally to the measured energy. The energy
consumption of the meter is very low, less than 0.6 VA.
Data from DELTAmax is collected via pulse output or serial communication. The pulse output is
A Polarity Independent Solid State Relay that generates pulses proportionally to
the measured energy. DELTAmax can be equipped with a built-in communication interface for M-Bus. All DELTAmax meters come
with an infrared port for communication with an external Serial Communication Adapter (SCA).
|
 ISL-A 600 |
ISL range allows protection in IT circuits monitoring the insulation to earth downstream the inverter. In
PV plants, where operational continuity is important, insulation monitoring device can be installed in order to prevent
faults and reduce maintenance which affect the overall pay back period on the investment. No auxiliary supply is needed.
|
|
Our industrial factory automation supplies distributors warehouse in Boise, Idaho USA stocks some ABB Low
Voltage products enabling us to further assist you in finding the correct circuit breaker in the USA, Canada and Mexico.
Whether we have switch disconnector in stock in Boise, Idaho USA or need to get them from ABB Group; Clearwater Tech can
get fuse disconnector to you fast and save you some money! It will be very helpful if you have the surge protector part
numbers ready, then our sales representatives can provide you with a pricing and availability quote for residual current
devices that you are looking for in seconds. If you do not have the part numbers for grid connection relays, our application
engineers will be able to help you figure out the part numbers and get the price quote to you as soon as possible.
|
|
|
|
 |
|
| Part Number: |
|
|
Can't find a part number?
E-mail Us! |
|
|