TURCK Gateways

Most AS-I/ PROFIBUS Gateways draw power from the AS-I power supply. The option to use a separate, non-AS-I power supply is also available. Consult the gateway documentation to ensure that the gateway being selected meets the requirements of your system. PROFIBUS stations must have a network address for communication. The address for AS-I/ PROFIBUS gateways may be set via the on-unit display and push buttons.

Banner Wireless

The SureCross Performance Wireless I/O Network provides reliable monitoring without the burden of wiring or conduit installation. The SureCross wireless network can operate independently or in conjunction with a host system, PLC, and/or PC software. Each wireless network system consists of one Gateway and one or more Nodes. Devices ship with factory defined inputs and outputs that may be all discrete, all analog, or a mix of discrete and analog I/O.

ABB Low Voltage

Home   >   Products   >   Jokab   >   Pluto PLC

ABB Low Voltage Controls

(800) 894-0412       (888) 723-4773 (Fax)
info@clrwtr.com

ABB Jokab Pluto Safety PLC Distributors
Pluto PLC

Pluto Safety PLC facilitates the design of your safety systems. Pluto is an All-Master system for dynamic and static safety circuits where inputs and other information are shared over the bus. Multiple safety sensors can be connected to a single input and still achieve the highest level of safety. Pluto has inputs suited for every safety product on the market, and each input function is configured in the accompanying software Pluto Manager.

Besides failsafe inputs (I) Pluto has a number of Failsafe Relay & Transistor Outputs (Q). On every Pluto unit there is also a possibility of using a number of terminals as failsafe inputs, non-failsafe outputs or both in and output simultaneously (IQ). The characteristics of the terminals are easily configured in Pluto Manager.

If you are looking for ABB Jokab Safety Pluto PLCs, please call us on (800) 894 - 0412 or email us at info@clrwtr.com we will do our best to help you find the ABB PROFIBUS Pluto Gateways that you are looking for at the most competitive prices possible. If you are searching for ABB DeviceNet Pluto Gateway technical information (data-sheets) please use the datasheets or product selection guide page links.

ABB Jokab GATE-P2 Profibus DP Pluto Gateways Distributor
GATE-P2 Profibus DP

Pluto gateway is a unit providing two-way communication between a Pluto safety PLC and other field buses. To simplify the integration of a Pluto gateway PROFIBUS into the supervisory PLC system, ABB Jokab Safety provides ready-made function blocks for several popular brands of PLC. The function blocks make it easier to receive and send information to the Pluto system. The function blocks are supplied as open units with full access for the customer to change and add functions.

  • Two-way communication
  • Built-in filter function, shared network
  • Only 22.5 mm wide
  • Can be located anywhere in the databus
  • Common interface with Pluto
  • Ready-made function blocks
ABB Jokab GATE-D2 DeviceNet Pluto Gateways Distributors
GATE-D2 DeviceNet

The Pluto gateway is a compact unit mounted on a DIN rail, and can be connected anywhere in a Pluto safety bus. The unit has a common interface with Pluto, i.e. the same cabling, and the Pluto Manager PC program can be used for servicing and where necessary programming. Normally, however, all the settings are made via a DIP switches, which means that programming tools are not required to put the gateway itself into operation.

A GATE-D2 can also be used to advantage as a CAN bridge when it is required to divide a Pluto safety bus into several sections. This is particularly useful when long databus cables are needed. PLUTO GATE-D2 has support for integration into an ABB Robotics IRC5-system.

ABB Jokab GATE-C2 CANopen Pluto Gateways Distributor
GATE-C2 CANopen

For programming Pluto there are ready-made function blocks which, via a Pluto gateway, send and receive data from the supervisory system. Via CANopen a supervisory PLC system can have access to the I/O and other variables in a Pluto safety PLC. Global I/Os in a Pluto safety PLC are accessible via CANopen PDO messages. Local data in Pluto units can be read via CANopen SDO messages together with the PLC codes in the supervisory system.

Via CANopen a supervisory PLC system can send nonsafety-related information to a Pluto safety PLC. A total of 64 Boolean values and 8 different 16-bit registers can be transmitted (CANopen PDO or SDO messages). Function blocks for these commands are available in Pluto Manager. A GATE-C2 can also be used to advantage as a CAN bridge when it is required to divide a Pluto safety bus into several sections. This is particularly useful when long databus cables are needed.

ABB Jokab GATE-E2 Profinet Ethernet/IP Modbus TCP Pluto Gateways Distributors
GATE-E2 Profinet

PLUTO Gateway GATE-E2 handles the status from and to Pluto safety PLCs via Ethernet protocols EtherNet/IP, PROFINET, Modbus TCP and a simple binary protocol that uses TCP/IP. For IP-address configuration, etc. there is a simple web server and a terminal server. Via one of the Ethernet protocols a supervisory PLC system can have access to the I/O and other variables in a Pluto safety PLC. Global I/Os in a Pluto safety PLC are accessible via the usual I/O transfer in the respective protocol. Local data in Pluto units can be read by special commands together with the PLC codes in the supervisory system.

Via the Ethernet protocol a supervisory PLC system can transmit non-safety-related information to a Pluto safety PLC. A total of 64 Boolean values and 8 different 16-bit registers can be transmitted. Function blocks for these functions are available in Pluto Manager.

ABB Jokab Pluto Rotational Absolute Value Sensors Distributor
Encoders

Together with a Pluto safety PLC, this rotational absolute encoder can be used for safe position determination. This is particularly useful in the case of such equipment as gantry robots, industrial robots, etc. Also in eccentric shaft presses, existing cam mechanisms can be replaced by absolute value position sensors for safe positioning. The sensors are available in single and multi-turn versions.

Up to 16 absolute encoders can be connected to a Pluto CAN databus. A Pluto on the databus reads the sensor values, which are evaluated. With a special function block in the PLC code, it is possible to design two-channel solutions with the sensors. The user can obtain safe values for position and speed from these values. This enables supervision of stationary and overspeed conditions.

Our industrial factory automation supplies distributors warehouse in Boise, Idaho USA stocks some Jokab Safety Pluto PLC products enabling us to further assist you in finding the correct Gate P2-Profibus DP in the USA, Canada and Mexico. Whether we have Gate D2-DeviceNet in stock in Boise, Idaho USA or need to get them from ABB Low Voltage Controls; Clearwater Tech can get Gate C2-CANOpen to you fast and save you some money! It will be very helpful if you have the Gate E2-Profinet part numbers ready, then our sales representatives can provide you with a pricing and availability quote for Gate E2-Ethernet/IP that you are looking for in seconds. If you do not have the part numbers for Gate E2-Modbus TCP, our application engineers will be able to help you figure out the part numbers and get the price quote to you as soon as possible.