(800) 894-0412 (208) 368-0415 (Fax) info@clrwtr.com |
 Emergency Stop Safety Modules Model ES-FA-11AA |
Banner E-Stop Modules Model ES-FA-11AA
- Monitors one dual-channel normally closed emergency stop switch circuit for a contact failure or wiring fault
- Two output switching channels for connection to control-reliable power interrupt circuits and one NC Auxilary
output
- Auto reset or monitored manual reset
- Design complies with standards UL991, ISO 13850 (EN418), and ISO 13849-1 (EN954-1) (Safety Category 4)
- For use in functional stop category 0 applications per NFPA 79 and IEC/EN60204-1
- 7 amp safety output contacts
- lug-in terminal blocks
- 24V ac/dc operation
- External device monitoring (one-channel EDM)
|
|
If you are looking for Banner E-Stop Modules, please call us on
(800) 894 - 0412 or email us at
info@clrwtr.com
we will do our best to help you find the Banner Gate Monitoring Modules that you are looking for at the most competitive prices
possible. If you are searching for Banner Machine Safety Switch technical information (data-sheets) please use the datasheets or
product selection guide page links.
|
 ES-FA-6G 1-Channel Emergency Stop Safety Relays |
Banner ES-FA-6G 1-Channel Emergency Stop Modules
- Monitors one single-channel normally closed Emergency Stop switch circuit for a contact failure or wiring fault
- Three output switching channels for connection to control-reliable power interrupt circuits
- Auto reset or manual reset
- One auxiliary non-safety N/C output contact for status monitoring by process controller
- Design complies with standards UL991, EN418, and EN954-1 (Safety Category 2)
- For use in functional stop category 0 applications per NFPA 79 and EN418
- 6 amp safety output contacts
|
 Emergency Stop Safety Modules Model ES-UA-5A/ES-VA-5A |
Banner Emergency Stop Modules Model ES-UA-5A/ES-VA-5A
- Monitors one dual-channel normally closed Emergency Stop switch circuit for a contact failure or wiring fault
- Four output switching channels for connection to control-reliable power interrupt circuits
- Auto reset or monitored manual reset
- Design complies with standards UL 991, EN 418, and EN 954-1 (Category 4)
- For use in functional stop category 0 applications per NFPA 79 and IEC/EN 60204-1
- 6 amp safety output contacts
- Plug-in terminal blocks
- 12-24V dc/115V ac or 12-24V dc/230V ac operation
- External Device Monitoring (one-channel EDM)
|
 GM-FA-10J Gate Monitoring Safety Modules |
Banner Model GM-FA-10J Gate Monitoring Modules
- Monitors one or two safety switches for a contact failure or wiring fault
- Two output switching channels for connection to control-reliable power interrupt circuits
- Auto reset or monitored manual reset
- Design complies with standards UL991, ISO 14119, and ISO 13849-1 (EN954-1) (Safety Category 2, 3 or 4)
- For use in functional stop category 0 applications per NFPA 79 and IEC 60204-1
- 6 amp safety output contacts
- Plug-in terminal blocks
- If terminal blocks are swapped, Module remains functional with no loss of safety function
|
 SI-MAG Series Machine Safety Switches |
Banner SI-MAG Series Magnetic Style Machine Switches
- Non-contact safety switches are the best choice for washdown applications; the switch components are sealed and rated
NEMA 4X, IEC IP67
- Tolerant of dirt buildup, sensing distance, and alignment
- System consists of three components:
- Coded magnet
- Reed switch sensor
- Controller module
- Magnet contains several differently-polarized magnets, and sensor contains pole-stable reed contacts to minimize
any possibility of defeat
- Easy installation; can be concealed for added defeat resistance
- Sensor reed switches provide diverse input to the controller module
|
 ES-FA-9AA & ES-FA-11AA Emergency Stop Safety Modules |
Banner ES-FA-9AA And ES-FA-11AA E-Stop Modules
- Monitors emergency stop devices, such as palm buttons and rope/cable pulls, and positive-opening safety switches used
for guard/gate interlocking
- The safety inputs can monitor:
- A +24V dc source switched by hard/relay contacts in single-channel hookup, or
- Hard/relay contacts in a dual-channel hookup using terminals S11-S12 and S21-S22
- The ES-FA-9AA has three normally open output switching channels for connection to control-reliable power
interrupt circuits
- The ES-FA-11AA has two normally open output switching channels for connection to control-reliable power
interrupt circuits and one normally closed auxiliary output channel
- Automatic reset or monitored manual reset
|
 E-Stop Safety Modules Model ES-GA-5A/ES-HA-5A |
Banner Emergency Stop Modules Model ES-GA-5A/ES-HA-5A
- Monitors one dual-channel normally-closed emergency stop switch circuit for a contact failure or wiring fault
- Input monitoring circuit uses a diverse-redundant design
- Four output switching channels for connection to control-reliable power interrupt circuits
- Auto reset or monitored manual reset
- Auxiliary non-safety outputs for status monitoring by process controller: one electromechanical "hard" contact,
plus two solid-state outputs
- Design complies with standards UL991, EN 418, and EN 954-1 (Safety Category 4)
- For use in functional stop category 0 applications per NFPA 79 and EN 418
- 5 amp safety output contacts
- Plug-in terminal blocks
|
 10-Input Emergency Stop Safety Modules |
Banner Ten-Input Emergency Stop Module Model ES-TA-3F1 With DeviceNet
- Monitors up to ten normally-closed Emergency Stop switch circuits for a contact failure or wiring fault
- Diverse-redundant input monitoring circuit
- DeviceNet monitoring of status and diagnostic information
- Auto reset or monitored manual reset
- Two output switching channels for connection to control-reliable power interrupt circuits
- Designed to comply with standards UL991, EN418, and EN954-1 (Safety Category 4)
- For use in functional stop category 0 applications per NFPA 79 and EN418
- Plug-in terminal blocks and replaceable circuit boards
- LED indicators for status of all inputs and outputs
- Manual MAC ID Address switches and LED
- Autobaud
|
 Six Input Emergency Stop Monitoring Safety Relays |
Banner Six Input Emergency Stop Monitoring Relays Model ES-TA-3D1 With DeviceNet
- Monitors up to six normally-closed emergency stop switch circuits for a contact failure or wiring fault
- Diverse-redundant input monitoring circuit
- DeviceNet monitoring of status and diagnostic information
- Auto reset or monitored manual reset
- Two output switching channels for connection to control-reliable power interrupt circuits
- Designed to comply with standards UL991, EN418, and EN954-1 (Safety Category 4)
- For use in functional stop category 0 applications per NFPA 79 and EN418
- Plug-in terminal blocks and replaceable circuit boards
- LED indicators for status of all inputs and outputs
- Manual MAC ID Address Switches and LED
- Autobaud
|
 E-Stop Safety Modules with Adjustable Delay |
Banner E-Stop Modules with Adjustable Delay Models ES-TN-14H5/ES-TN-14H6
- Selectable Auto-Reset or monitored Manual Reset.
- Auto or manual power-up
- One- or two-channel feedback monitoring
- Monitors one dual-channel or one single-channel normally closed E-stop switch circuit for a contact failure or
wiring fault (safety category 2 or 4, per ISO13849-1 [EN954-1]; see pages 5-7).
- 4 amp safety output contacts
- Removable terminal blocks
- Input monitoring circuit has diverse-redundant microprocessors
- Designed for use in functional stop Category 0 and 1 applications (per ISO/EN 60204-1 and NFPA79)
- Four immediate output switching channels (functional stop Category 0) and four delayed output switching channels
(functional stop Category 1). Delay time is adjustable from 0-20 seconds or 0-200 seconds, depending on model.
- One auxiliary non-safety, normally closed immediate output and one auxiliary non-safety normally closed delayed
output for status monitoring.
|
 Emergency-Stop Safety Modules |
Banner E-Stop Modules with Adjustable Delay Models ES-TN-1H5/ES-TN-1H6
- Selectable Auto-Reset or monitored Manual Reset.
- Auto or manual power-up
- One- or two-channel feedback monitoring
- Monitors one dual-channel or one single-channel normally closed E-stop switch circuit for a contact failure or
wiring fault (safety category 2 or 4, per EN954-1; see pages 5 and 6).
- 4 amp safety output contacts
- Removable terminal blocks
- Input monitoring circuit has diverse-redundant microprocessors
- Designed for use in functional stop Category 0 and 1 applications (per EN 60204-1 and NFPA79)
- Two immediate output switching channels (functional stop Category 0) and two delayed output switching channels
(functional stop Category 1). Delay time is adjustable from 0-20 seconds or 0-200 seconds, depending on model.
- One auxiliary non-safety, normally closed immediate output and one auxiliary non-safety normally closed delayed
output for status monitoring.
|
 ES-TN-1H E-Stop Safety Modules With Fixed Delay |
Banner ES-TN-1H E-Stop Modules with Fixed Delay
- Selectable Auto-Reset or monitored Manual Reset.
- Auto or manual power-up
- One- or two-channel feedback monitoring
- Monitors one dual-channel or one single-channel normally closed E-stop switch circuit for a contact failure or wiring
fault (Safety Category 2 or 4, per ISO13849-1 [EN954-1]; see pages 5 and 6).
- 4 amp safety output contacts
- Removable terminal blocks
- Input monitoring circuit has diverse-redundant microprocessors
- Designed for use in functional stop Category 0 and 1 applications (per ISO/EN 60204-1 and NFPA79)
- Two immediate output switching channels (functional stop Category 0) and two delayed output switching channels
(functional stop Category 1).
- One auxiliary non-safety, normally closed immediate output and one auxiliary non-safety normally closed delayed
output for status monitoring.
|
 Emergency Stop Monitoring Safety Relays |
Banner Emergency Stop Monitoring Relays Model ES-FL-2A
- Monitors two normally-closed emergency stop switch circuits for a contact failure or wiring fault
- Input monitoring circuit uses a diverse-redundant design
- Requires a reset routine for controlled re-application of power to the machinery as per ANSI standard B11.20-1991
- Two output switching channels for connection to control-reliable power interrupt circuits
- Auxiliary non-safety contact for status monitoring by process controller
- Design complies with standards UL991, EN418, and EN954-1(Safety Category 4)
- UL approved as Category NISD Emergency Stop Device
- For use in functional stop category 0 applications per NFPA 79 and EN418
|
|
Our Banner Engineering distributors warehouse in Boise, Idaho stocks some Banner Emergency Stop Switches
enabling us to further assist you in finding the correct Banner Gate Monitoring Module for your application in the Pacific Northwest
USA. We can proudly say that we carry more Banner Engineering E-Stops in stock than any other Banner Engineering
distributors in the Pacific Northwest region. Whether we have Banner Machine Safety Switch in stock in Boise,
Idaho or need to get them from Banner Engineering; Clearwater Tech can get Banner Sensors to you fast and save money!
It will be very helpful if you have the Banner Gate Monitoring Modules part numbers ready, then
our sales representatives can provide you with a pricing and availability quote for Banner Emergency Stop Switches that you
are looking for in seconds. If you do not have the part numbers for Banner Safety Relays, our application engineers will be
able to help you figure out the part numbers and get the price quote to you as soon as possible.
Please be aware that we cannot sell Banner Sensors out of our Area of Primary
Responsibility (APR).
|