TURCK Modules
Bihl+Wiedemann AS-interface
(commonly referred to as AS-I) is a low-level I/O interface system. It was originally intended to be a simple, low cost
system that would be easy to install and maintain. With that philosophy in mind, the original developers designed AS-I
as a discrete-only two-wire system.
Industrial Input Stations
|
Weidmuller Converters
Devices in the Micromann UPI Series
convert analogue current and voltage signals to a proportional frequency. Measurement errors (which can occur with low input
frequencies) are elimated with an adjustable frequency suppression. In addition, a quadratic function linearizes the
signals. External two-wire measuring transducers can be supplied with power directly from the analogue frequency
converter.
|
|
|
|
 |
(800) 894-0412 (888) 723-4773 (Fax) info@clrwtr.com |
 Models IM-T-9A & IM-T-11A Modules |
Banner Models IM-T-9A & IM-T-11A Interface Modules
- Interface Modules provide isolated safety output contacts for a primary safety device (e.g., a
Safety Light Screen or
Safety Module) which has solid-state or hard contact outputs and external device monitoring (EDM) capability.
- Model IM-T-9A features three normally open 6 amp redundant-output channels.
- Model IM-T-11A features two normally open redundant-output channels and one normally closed non-safety auxiliary
output channel, all rated at 6 amps.
- Normally closed outputs for connection to the primary safety device's monitoring input.
- 24V dc operation
- 22.5 mm (0.9") DIN-rail-mountable housing
- Convenient plug-in terminal blocks
|
|
If you are looking for Banner Interface Modules, please call us on
(800) 894 - 0412 or email us at
info@clrwtr.com
we will do our best to help you find the Model IM-T-9A Module that you are looking for at the most competitive prices
possible. If you are searching for Interface Module technical information (data-sheets) please use the datasheets or product
selection guide page links.
|
 Model SC-IM9 Modules |
Banner Models SC-IM9 Interface Modules
- Provides isolated safety output contacts for the SC22-3 Safety Controller, which has solid-state outputs and
external device monitoring (EDM) capability.
- Designed specifically for use with one, two or three Safety Controller safety outputs.
- Features three normally open redundant-output channels and one normally closed monitoring output channel for each
safety output.
- Has contacts rated at 10 amps.
- Operates on 24V dc, supplied by the Safety Controller.
- Mounts to standard DIN rail.
|
|
Our industrial factory automation supplies distributors warehouse in Boise, Idaho stocks some Banner Interface Modules
enabling us to further assist you in finding the correct Banner SC-IM9 Interface Module for your application in the Pacific
Northwest USA. We can proudly say that we carry more Banner Engineering Interface Module in stock than any other Banner
Engineering distributors in the Pacific Northwest region. Whether we have Banner SC-IM9 Interface Modules in stock in Boise,
Idaho or need to get them from Banner Engineering; Clearwater Tech can get Banner Module to you fast and save money!
It will be very helpful if you have the Banner Interface Modules part numbers ready, then
our sales representatives can provide you with a pricing and availability quote for Banner SC-IM9 Interface Module that you
are looking for in seconds. If you do not have the part numbers for Banner IM-T-9A Module, our application engineers will be
able to help you figure out the part numbers and get the price quote to you as soon as possible.