Banner Safety Modules Controllers Universal Input E-Stop Guard Monitoring Interface SC22-3E Extension DUO-TOUCH SG
Banner Engineering Distributors
Banner Safety Modules Controllers Universal Input E-Stop Guard Monitoring Interface SC22-3E Extension DUO-TOUCH SG
Banner Safety Modules Controllers Universal Input E-Stop Guard Monitoring Interface SC22-3E Extension DUO-TOUCH SG

Sentrol Relays

INT-22.5R1-24 is a two-channel safety switching device with self-monitoring on each ON-OFF cycle. It conforms to EN 60204-1 and is equipped with positively driven relays. It is intended for monitoring connected switching elements on separating safety devices and generating a safety oriented output signal (enable). Depending on the design, separating safety devices may include protective screens, safety doors, enclosures, covers,

TURCK Power Supply

TURCK IP 67 power supplies offer unparalleled functionality and quality. They are exceptionally powerful, environmentally resistant and extremely small. Truly innovative and exactly what the automation industry is looking for in a power supply solution. The PSU67 power supply modules were designed for on-machine and factory floor installations, with the elimination of a traditional protective enclosure.

Banner Engineering

Loading

Home   >   Products   >   Banner   >   Safety Modules & Controllers

Banner Engineering

(800) 894-0412       (888) 723-4773 (Fax)
info@clrwtr.com

Banner UM-FA-9A/UM-FA-11A Series Universal Input Safety Modules Distributor
UM-FA-9A/UM-FA-11A Modules

Banner UM-FA-9A/UM-FA-11A Series Universal Input Safety Modules

  • Monitors a wide variety of safety and non-safety input devices:
    • Optical-based safeguarding devices, such as Safety Laser Scanners
    • Positive-opening safety switches used for guard interlocking
    • Emergency-stop devices, such as palm buttons and rope/cable pulls
    • Standard sensors for non-safety applications, such as photoelectric monitoring position or end-of-travel
  • UM-FA-9A: Three normally open (N.O.) output switching channels for connection to control-reliable power interrupt circuits
  • UM-FA-11A: Two normally open (N.O.) and one normally closed (N.C.) output switching channels for connection to control-reliable power interrupt circuits

If you are looking for Banner Safety Modules & Controllers, please call us on (800) 894 - 0412 or email us at info@clrwtr.com we will do our best to help you find the Banner Safety Module that you are looking for at the most competitive prices possible. If you are searching for Banner Safety Controller technical information (data-sheets) please use the Banner Engineering Modules & Controllers Datasheets OR Product Selection Guide page links.

Banner E-Stop Modules with Adjustable Delay Models ES-TN-1H5/ES-TN-1H6 Distributor
Emergency-Stop & Guard Monitoring Modules

Banner E-Stop & Guard Monitoring Modules

  • Modules monitor up to 10 external devices for contact failure or wiring faults.
  • Module goes into lockout mode if it detects a fault.
  • Available voltages include 24V dc; 24V ac/dc; 115V ac or 12 to 24V dc; or 230V ac or 12 to 24V ac/dc.
  • Modules monitor positive-opening E-stop and interlock switches.
  • Models are available with 2 to 4 normally open safety outputs, depending on module.
  • Safety outputs are rated 4 or 6 amps, depending on module.
  • Non-safety auxiliary outputs are available on most modules.
  • Modules are available with an adjustable output delay of 0-20 or 0-200 seconds, depending on module.
  • Two modules allow central monitoring and control over a DeviceNet control network.
  • Ratings are NEMA 1 and at least IEC IP20.
  • Housings are rugged polycarbonate.
  • Bright red and green LED indicators show module's operating status.
Banner SC22-3/SC22-3E Controllers With Ethernet Distributor
SC22-3/SC22-3E Safety Controllers

Banner Engineering SC22-3/SC22-3E Controller

  • 22 input terminals can monitor both contact-based or PNP solid-state outputs from Banner devices or any other manufacturers
  • Each input can be a non-safety input, or configured for Control Reliability or Category 2, 3 or 4 safety circuit performance per ISO 13849-1
  • 3 pairs of solid-state safety outputs rated at 0.75A each (24V dc) with selectable one - or two-channel external device monitoring and ON-delay or OFF-dalay
  • 10 configurable auxiliary status outputs track inputs, outputs, lockout, I/O status and other functions
  • Easy configuration with built-in front panel LCD display or PC Interface
  • Live Display and a Fault Log provide real-time system and fault history identification
  • Controller is designed to meet stringent standards including Safety Integrity Level (SIL) 3 per IEC 62061 and IEC 61508, and Category 4 Performance Level (PL e) per ISO 13849-1
Model SC-IM9 Module For Use With The SC22-3 Safety Controller DistributorInterface Modules

Interface Modules

Interface Modules IM-T-9A and IM-T-11A (the Interface Modules) operate on 24V dc inputs and provide isolated redundant output channels for interfacing dc safety controls (such as safety light screens or other safety modules) to safety circuits. These modules can also be used to switch low power capacity of safety controls with low current output rating (see hookup figures and the output configuration specifications).

Interface Modules SC-IM9.. operate on 24V dc inputs and provide isolated redundant output channels for interfacing the Safety Controller's solid-state 24V dc outputs to ac safety circuits. The normally open safety contacts of the Interface Module will follow the action of the safety outputs from the Safety Controller within 3 milliseconds when going from closed to open (for other response times, see Specifications). All Interface Module contacts are rated for up to 690V ac/dc at up to 10 amps.

Banner EM-F-7G Safety Extension Modules Delayed Output Distributor
Extension Modules

Banner Engineering Extension Modules

  • Provides additional safety outputs for a primary safety device
  • Offers four normally open (NO) safety outputs
  • Provides delayed or immediate outputs, depending on model
  • Offers choice of 24V dc or 24V ac/dc supply voltage, depending on model
  • Requires no adjustments
  • If malfunctioning, signals primary safety device to react
  • Responds in milliseconds
  • Designed to meet standards UL 509, UL 991, EN 418 and ISO 13850
  • Rated IEC IP20; NEMA 1
Banner DUO-TOUCH SG Two-Hand Control Modules Models AT-GM-13A AT-HM-13A For Use With Two Actuating Devices Distributor
DUO-TOUCH SG Two-Hand Control

Banner DUO-TOUCH SG Two-Hand Control Safety Modules

  • Modules work with Banner STB self-checking touch buttons or can be retrofitted with existing mechanical palm buttons to create a complete, ergonomic two-hand control system.
  • To ensure reliability, modules have a diverse-redundant microcontroller circuit and multiple redundant, force-guided (mechanically linked) output contacts.
  • Anti-tiedown logic requires that both touch buttons are activated within one-half second of each other.
  • Ac and dc voltages are available: 24V ac/dc, 115V ac/24V dc or 230V ac/24V dc.
  • Modules are available with two or four normally open (NO) safety outputs.
  • Non-safety auxiliary outputs are available on some models.
  • Modules meet Safety Category 4 per ISO 13849-1 (EN 954-1) and functional Type IIIC two-hand control per EN 574.
  • Removable terminal blocks allow convenient wiring and exchange of modules without rewiring.
  • Optional mute inputs allow release of actuating buttons during the non-hazardous portion of the machine cycle.
  • Available kits include module and two STB touch buttons.
  • STB touch buttons are far more ergonomic than mechanical and difficult-to-activate capacitive buttons.
Banner SSM-FM-11A** Safe Speed Monitoring Modules Distributors
SSM-FM-11A10 & SSM-FM-11A20

Speed Monitoring

The SSM-FM-11A** Safe Speed Monitoring Module ("the Module") can be used to monitor a rotating or laterally moving device's stopping, starting, or speed. The Module requires signals from two independent sensors.

As a "standstill" (under-speed) monitor, the Module is often used in combination with hard guarding, access doors, and safety gates with solenoid-lock or -unlock safety switches. When the speed of the monitored device drops below the set switch point (where its speed is no longer considered dangerous), the Module closes its safety output contacts, applying power to the safety switch solenoid, releasing the switch lock and enabling the operator to open the safety gate.

Banner Muting Modules Model MM-TA-12B Distributor
Muting Module Family

Banner Muting Module Family

  • Suspends safeguarding during hazard-free times in the machine's cycle
  • Allows material to move into or from the process, without tripping the primary safeguard
  • Monitors two or four hard-relay contact or OSSD output safety devices
  • Available in models for Type 2 and Type 4 applications
  • Offers 24V dc supply voltage with either two solid-state OSSD or 2 normally open (NO) safety outputs
  • Includes one non-safety auxiliary output
  • Offers two reset options: Automatic and Monitored Manual
  • Uses diverse redundancy and self-checking, for reliability
  • Features models for DIN-rail mounting or IP65-rated housing for flat mounting
  • Mounts outside a control panel, near the muted safeguard, or inside the control panel
  • Installs easily
  • Connects to supplemental safeguarding devices or E-stops
Banner SM-*A-5A Safety Mat Monitoring Modules Distributors
SM-GA-5A & SM-HA-5A

Safety Mat Monitoring

Safety Mat Monitor Modules SM-GA-5A and SM-HA-5A (the "Safety Module") are used to verify the proper operation of 4-wire presence-sensing switching mats (sensors).

In operation, the Safety Module monitors the conductive elements (plates) of the pressure-sensitive mat for shorting of those elements (i.e., when the mat is stepped on) and certain faults, such as shorts to other sources of power or ground (0V), or open connecting wires. With a +24V dc supply, Channel 1 (S11-S12) supplies > 20V dc that is pulsed low and Channel 2 (S21-S22) supplies < 2V that is pulsed high; when these two channels are shorted together, the safety output contacts open (13-14, 23-24, 33-34, and 43-44).

Our industrial factory automation supplies distributors warehouse in Boise, Idaho stocks some Banner Universal Input Modules enabling us to further assist you in finding the correct Banner Controllers for your application in the Pacific Northwest USA. We can proudly say that we carry more Banner Engineering Safe Speed Monitoring Modules in stock than any other Banner Engineering distributors in the Pacific Northwest region. Whether we have Banner Safety Mat Monitor Modules in stock in Boise, Idaho or need to get them from Banner Engineering; Clearwater Tech can get Banner Controllers to you fast and save money!

It will be very helpful if you have the Banner Module & Controller part numbers ready, then our sales representatives can provide you with a pricing and availability quote for Banner Universal Input Module that you are looking for in seconds. If you do not have the part numbers for Banner Controller, our application engineers will be able to help you figure out the part numbers and get the price quote to you as soon as possible.

Please be aware that we cannot sell Banner Sensors out of our Area of Primary Responsibility (APR).

Clearwater Tech Site Usage Policy
Part Number:
Manufacturer:

Search Tips

Can't find a part number?
E-mail Us!

Banner Safety Modules Controllers Universal Input E-Stop Guard Monitoring Interface SC22-3E Extension DUO-TOUCH SG
Banner Safety Modules Controllers Universal Input E-Stop Guard Monitoring Interface SC22-3E Extension DUO-TOUCH SG
Banner Engineering Distributors
Clearwater Tech   © 2010 PRIVACY POLICY TERMS OF USE LEGAL INFO USAGE POLICY