January 20, 2010
TURCK Controllers
Limit Value Monitors
IM43-13-SR and IM43-14-SRi are single-channel devices and alternately monitor measuring current of 0/4-20 mA or measuring
voltages of 0/2-10 V. The three limit values are set via the front panel teach button. In addition, a voltage of approx.
18 V (at 35 mA max.) is provided
1 Channel Temperature Converters
|
CONTRINEX Relays
SAFETINEX safety
relay, or light curtain controller, is a type 4 device, designed for the protection of people and machines. It can be used
in applications together with Electro-sensitive protective equipment type 4 (light curtains and Light Barriers)
Safety Relay Controllers
|
|
|
|
 |
(800) 894-0412 (208) 368-0415 (Fax) info@clrwtr.com |
 Banner UM-FA-9A/UM-FA-11A Safety Modules |
Banner UM-FA-9A/UM-FA-11A Series Universal Input Safety Modules
- Monitors a wide variety of safety and non-safety input devices:
- Optical-based safeguarding devices, such as Safety Laser Scanners
- Positive-opening safety switches used for guard interlocking
- Emergency-stop devices, such as palm buttons and rope/cable pulls
- Standard sensors for non-safety applications, such as photoelectric monitoring position or end-of-travel
- UM-FA-9A: Three normally open (N.O.) output switching channels for connection to control-reliable power interrupt
circuits
- UM-FA-11A: Two normally open (N.O.) and one normally closed (N.C.) output switching channels for connection to
control-reliable power interrupt circuits
|
|
If you are looking for Banner Safety Modules & Controllers, please call us on
(800) 894 - 0412 or email us at
info@clrwtr.com we
will do our best to help you find the Banner Safety Module that you are looking for at the most competitive prices possible. If
you are searching for Banner Safety Controller technical information (data-sheets) please use the
Banner Engineering Modules & Controllers Datasheets OR
Product Selection Guide page links.
|
 Banner Emergency-Stop & Guard Monitoring Modules |
Banner E-Stop & Guard Monitoring Modules
- Modules monitor up to 10 external devices for contact failure or wiring faults.
- Module goes into lockout mode if it detects a fault.
- Available voltages include 24V dc; 24V ac/dc; 115V ac or 12 to 24V dc; or 230V ac or 12 to 24V ac/dc.
- Modules monitor positive-opening E-stop and interlock switches.
- Models are available with 2 to 4 normally open safety outputs, depending on module.
- Safety outputs are rated 4 or 6 amps, depending on module.
- Non-safety auxiliary outputs are available on most modules.
- Modules are available with an adjustable output delay of 0-20 or 0-200 seconds, depending on module.
- Two modules allow central monitoring and control over a DeviceNet control network.
- Ratings are NEMA 1 and at least IEC IP20.
- Housings are rugged polycarbonate.
- Bright red and green LED indicators show module's operating status.
|
 Banner Engineering SC22-3/SC22-3E Safety Controllers |
Banner Engineering SC22-3/SC22-3E Controller
- 22 input terminals can monitor both contact-based or PNP solid-state outputs from Banner devices or any other
manufacturers
- Each input can be a non-safety input, or configured for Control Reliability or Category 2, 3 or 4 safety circuit
performance per ISO 13849-1
- 3 pairs of solid-state safety outputs rated at 0.75A each (24V dc) with selectable one - or two-channel external
device monitoring and ON-delay or OFF-dalay
- 10 configurable auxiliary status outputs track inputs, outputs, lockout, I/O status and other functions
- Easy configuration with built-in front panel LCD display or PC Interface
- Live Display and a Fault Log provide real-time system and fault history identification
- Controller is designed to meet stringent standards including Safety Integrity Level (SIL) 3 per IEC 62061 and
IEC 61508, and Category 4 Performance Level (PL e) per ISO 13849-1
|
 Banner Engineering Interface Modules |
Banner Engineering Interface Modules
- Increases the switching current capacity of low voltage primary safety devices to 6 amps
- Serves as a relay for primary safety devices with OSSD solid-state or hard contact outputs and external device
monitoring, such as the EZ-SCREEN
- Offers 24V dc supply voltage
- Available with two or three normally open (NO) safety outputs, depending on model
- Features model with one normally closed (NC) non-safety auxiliary output
- Includes removable terminal blocks
- Responds in 20 milliseconds
- Uses two green LEDs to indicate the output status of internal relays K1 and K2
- Rated IEC IP20; NEMA 1
|
 Banner Engineering Extension Modules |
Banner Engineering Extension Modules
- Provides additional safety outputs for a primary safety device
- Offers four normally open (NO) safety outputs
- Provides delayed or immediate outputs, depending on model
- Offers choice of 24V dc or 24V ac/dc supply voltage, depending on model
- Requires no adjustments
- If malfunctioning, signals primary safety device to react
- Responds in milliseconds
- Designed to meet standards UL 509, UL 991, EN 418 and ISO 13850
- Rated IEC IP20; NEMA 1
|
 Banner DUO-TOUCH SG Two-Hand Control Safety Modules |
Banner DUO-TOUCH SG Two-Hand Control Safety Modules
- Modules work with Banner STB self-checking touch buttons or can be retrofitted with existing mechanical palm buttons
to create a complete, ergonomic two-hand control system.
- To ensure reliability, modules have a diverse-redundant microcontroller circuit and multiple redundant, force-guided
(mechanically linked) output contacts.
- Anti-tiedown logic requires that both touch buttons are activated within one-half second of each other.
- Ac and dc voltages are available: 24V ac/dc, 115V ac/24V dc or 230V ac/24V dc.
- Modules are available with two or four normally open (NO) safety outputs.
- Non-safety auxiliary outputs are available on some models.
- Modules meet Safety Category 4 per ISO 13849-1 (EN 954-1) and functional Type IIIC two-hand control per EN 574.
- Removable terminal blocks allow convenient wiring and exchange of modules without rewiring.
- Optional mute inputs allow release of actuating buttons during the non-hazardous portion of the machine cycle.
- Available kits include module and two STB touch buttons.
- STB touch buttons are far more ergonomic than mechanical and difficult-to-activate capacitive buttons.
|
 Banner SSM-FM-11A Safe Speed Monitoring Modules |
Banner SSM-FM-11A Safe Speed Monitoring Modules
- Feedback input monitors external machine control elements
- 24V ac/dc operation
- Two redundant, forced guided output contacts rated at 4A, plus one auxiliary N.C. output contact
- Stop Category 0, per ISO 13850 (EN 418), IEC 60204-1, and ANSI NFPA 79; Category 3, SIL Claimed Level (SIL CL) 3 to
EN 62061, Category 3 / Performance Level (PL) e to DIN EN ISO 13849-1
- DIN-rail mountable 45 mm wide housing with removable terminal blocks
- Energizes output relays (closes N.O. contacts), when speed drops below set value, for "standstill" (under-speed)
monitoring
- De-energizes output relays (opens N.O. contacts), when speed rises above set value, for over-speed monitoring
|
 Banner Engineering Muting Module Family |
Banner Muting Module Family
- Suspends safeguarding during hazard-free times in the machine's cycle
- Allows material to move into or from the process, without tripping the primary safeguard
- Monitors two or four hard-relay contact or OSSD output safety devices
- Available in models for Type 2 and Type 4 applications
- Offers 24V dc supply voltage with either two solid-state OSSD or 2 normally open (NO) safety outputs
- Includes one non-safety auxiliary output
- Offers two reset options: Automatic and Monitored Manual
- Uses diverse redundancy and self-checking, for reliability
- Features models for DIN-rail mounting or IP65-rated housing for flat mounting
- Mounts outside a control panel, near the muted safeguard, or inside the control panel
- Installs easily
- Connects to supplemental safeguarding devices or E-stops
|
 Banner Engineering Monitoring Modules Models SM-GA-5A & SM-HA-5A |
Banner Safety Mat Monitor Modules Models SM-GA-5A & SM-HA-5A
- Monitors a single mat or a series of connected mats
- Uses a standard 4-wire safety mat or edge triggered by a short in a contact plate or strip
- Offers choice of 115V ac/24V dc or 230V ac/24V dc supply voltage, depending on model
- Provides four normally open (NO) immediate safety outputs rated at 6 amps
- Includes one normally closed (NC) and two solid-state non-safety auxiliary outputs
- Features removable terminal blocks
- Resets automatically or manually
- Responds in 50 millisecond
- Meets US and international standards
- Rated IEC IP20; NEMA 1
|
 Banner Engineering PICO-GUARD Fiber Optic Safety Systems |
Banner PICO-GUARD Fiber Optic Safety Systems
- Uses compact, non-contact fiber optic technology for personnel safety and equipment protection
- Eliminates electrical wires and expensive electrical wiring, for easy installation
- Offers choice of 2-, 3- or 4-beam Grids and single-beam Points for perimeter and access guarding
- Features a variety of interlock switches for doors, guards, gates and covers
- Offers optical E-stop buttons for complementary protective measures to safeguarding devices that detect or prevent
inadvertent access to a hazard
- Includes four optical channels in each controller
- Available in controller models with optical channel auxiliary outputs and muting
- Includes two Universal Safety Stop Interface (USSI) inputs for direct connection of multiple safety devices
- Offers selectable trip or latch output, external device monitoring and auto/manual power-up
- Needs no alignment and doesn't wear out
- Meets Category 4 interlocking requirements with one switch per guard, even with multiple switches per optical
channel
- Offers ATEX, FM and CSA certification ratings for use in explosive environment
|
|
Our Banner Engineering distributors warehouse in Boise, Idaho stocks some Banner Universal Input Modules
enabling us to further assist you in finding the correct Banner Controllers for your application in the Pacific
Northwest USA. We can proudly say that we carry more Banner Engineering Safe Speed Monitoring Modules in stock than any
other Banner Engineering distributors in the Pacific Northwest region. Whether we have Banner Safety Mat Monitor Modules
in stock in Boise, Idaho or need to get them from Banner Engineering; Clearwater Tech can get Banner Controllers to you fast
and save money!
It will be very helpful if you have the Banner Module & Controller part numbers ready,
then our sales representatives can provide you with a pricing and availability quote for Banner Universal Input Module that
you are looking for in seconds. If you do not have the part numbers for Banner Controller, our application
engineers will be able to help you figure out the part numbers and get the price quote to you as soon as possible.
Please be aware that we cannot sell Banner Sensors out of our Area of Primary
Responsibility (APR).
|
|
|
|
 |
|
| Part Number: |
|
|
Can't find a part number?
E-mail Us! |
|
|