Clearwater Tech Logo
Loading
Home | Contact Us |
(800) 894-0412

Product Articles

Home   >   Products   >   Articles   >   General Conversation Tables

Length
SI UNIT - meter (m)
To convert from: To: Multiply by:
Mile m 1609.344
Nautical Mile m 1853
km m 103
cm m 10-2
mm m 10-3
yd m 0.914
ft m 0.305
in m 2.54 x 10-2
mil m 2.54 x 10-5


Area
SI UNIT - square meter (m2)
To convert from: To: Multiply by:
Square Miles m2 2.59 x 106
Acre m2 4047
Hectare ha m2 104
Km2 (sq. km) m2 106
cm2 m2 10-4
mm2 m2 10-6
yd2 m2 0.836
ft2 m2 9.29 x 10-2
in2 m2 6.45 x 10-4
mil2 m2 6.45 x 10-10


Volume
SI UNIT - cubic meter (m3)
To convert from: To: Multiply by:
yd3 m3 0.765
ft3 m3 2.83 x 10-2
in3 m3 1.64 x 10-4
dm3 m3 10-3
Litre m3 10-3
Gallon (Imperial) m3 4.55 x 10-3
Gallon (U.S.) m3 3.79 x 10-3
Pint (Imperial) m3 5.68 x 10-4
Pint (U.S.) m3 4.73 x 10-4


Mass
SI UNIT - kilogram (kg)
To convert from: To: Multiply by:
ton (Imperial) kg 1016
ton (U.S.) kg 907.2
tonne (metric) kg 103
slug kg 14.59
lb kg 0.454
oz kg 2.84 x 10-2
g kg 10-3


Force and Weight
SI UNIT - Newton (N)
To convert from: To: Multiply by:
tonf (ton wt) N 9964
lbf (lb wt) N 4.448
poundal N 0.138
ozf (oz wt) N 0.278
kp N 9.807
p N 9.81 x 10-2
kgf (kg wt) N 9.807
gf (g wt) N 9.81 x 10-2
dyn N 10-5


Pressure and Stress
SI UNIT - Pascal (Pa)
To convert from: To: Multiply by:
at (technical atmosphere) Pa 9.81 x 103
in WG Pa 248.9
mm WG Pa 10.34
in HG Pa 3385
mm HG (torr) Pa 131
kp cm-2 Pa 9.81 x 103
Nm-2 Pa 1
bar Pa 105
lbf ft-2 Pa 47.88
lbf in-2 Pa 6895
kgf m-2 Pa 9.807
kgf cm-2 Pa 9.81 x 104


Velocity (Linear)
SI UNIT - meter per second (ms-1)
To convert from: To: Multiply by:
mph (mile per hour) ms-1 0.447
ft min-1 ms-1 5.08 x 10-3
fts-1 ms-1 0.305
km h-1 ms-1 0.278
m min-1 ms-1 1.67 x 10-2
knot ms-1 0.515


Velocity (Angular)
SI UNIT - radians per second (rad s-1)
To convert from: To: Multiply by:
rpm (revolutions per min) rads-1 0.1037 (2Π/60)
rs-1 (revolutions per sec) rads-1 6.283 (2Π)
°s-1 (degrees per sec) rads-1 1.75 x 10-2 (2Π/360)


Torque
SI UNIT - Newton meter (Nm)
To convert from: To: Multiply by:
lbf ft Nm 1.356
lbf in Nm 0.113
ozf in Nm 7.062 x 10-3
kgf m Nm 9.807
kp m Nm 9.807


Energy
SI UNIT - Joule (J)
To convert from: To: Multiply by:
Btu J 1.055 x 103
therm (105 btu) J 1.055 x 108
cal J 4.187
ft lbf (ft lb wt) J 1.356
ft poundal J 0.042


Power
SI UNIT - kilowatt (kW)
To convert from: To: Multiply by:
hp kW 0.746
ps kW 0.736
ch, CV kW 0.736
Btu s-1 kW 1.055
kcal s-1 kW 4.187
ft lbf s-1 kW 1.36 x 10-3


Force
SI UNIT - Newton (N)
To convert from: To: Multiply by:
lb(f) N 4.448
N lb(f) 0.225


Moment of Inertia
SI UNIT - Kilogram meter2 (kgm2)
To convert from: To: Multiply by:
lb in s2 kgm2 0.113
oz in s2 kgm2 7.06155 x 10-2
kg m2 lb in s2 8.85075
kg m2 oz in s2 141.612
kg cm2 kgm2 10-4
kgf m2 (GD2) kgm2 0.25
lbf ft2 (WK2) kgm2 4.21 x 10-2
kp m s2 kgm2 9.807
ft lbf s2 kgm2 1.356
lbf in2 kgm2 2.926 x 10-4
ozf in2 kgm2 1.829 x 10-5


Temperature
SI UNIT - Kelvin (K)
To convert from: To: Multiply by:
°C K x 1
t°C K t+273.15
°F K x 0.5555
t°F K (t-32) x 0.5555


Flow
SI UNIT - cubic meter per second (m3s-1)
To convert from: To: Multiply by:
gallon per hour (Imp) m3s-1 1.26x10-6
gallon per hour (US) m3s-1 1.05x10-6
litre per hour m3s-1 1.67x10-5
litre per second m3s-1 10-3
cfm m3s-1 4.72x10-4
m3h-1 m3s-1 2.78x10-4
m3min-1 m3s-1 1.67x10-2


Torque
SI UNIT - Newton meter (Nm)
To convert from: To: Multiply by:
lb ft Nm 1.356
lb in Nm 0.113
oz in Nm 7.062 x 10-3
Nm lb ft 0.738
Nm lb ft 8.857
Nm oz in 141.6


Linear Acceleration
SI UNIT - meter per second2 (ms-2)
To convert from: To: Multiply by:
ins-2 ms-2 2.54 x 10-2
fts-2 ms-2 0.305
ms-2 ins-2 39.37
ms-2 fts-2 3.281
Stock Check
Part No:
OR
Manufacturer:

Search Tips

Can't find a part number?
E-mail Us!

Leuze Devices

Leuze Electronic MLD500 Type 4 series can be used both for access guarding as well as for applications with muting. Through various function classes (MLD 510, 520, 530, 535), the optimum design can always be selected. Configuration via PC or DIP switch is not necessary. Multiple Light Beam Safety Devices with muting function ensure constant personnel protection (access guarding) with unobstructed material infeed, e.g., in conveyor systems.

Sola Power Supply

Sola Hevi Duty SDN series standard options allow for operation in a wide variety of applications. With the addition of an external redundancy module, the SDN can also be used for true redundant operation including 2N and N+x configurations. All SDN units include built in current sharing for parallel and redundant operation. The external modules SDN 2.5-20RED and SDN 30/40RED increase the reliability by isolating the supplies and adding more