August 04, 2011
SUNX Safety Screens
The SF-AC Safety Relay Unit
is available for safety applications with a built-in power supply. With a 10ms response time and removable terminal blocks, the
SF-AC ensures safe and stable protection for your machines. The unit is equipped with a trailing edge switching function, which
causes an ON signal to be sent when the start switch signal is falling. This prevents unexpected starting which can occur if the
start switch gets welded.
|
GE Safety Relays
The INT-03-024 or INT-03-120,
Safety Monitor Relay is intended for use as a part of a safety circuit in guard interlock applications. It is a safety relay
which uses positive-guided relays, configured for self-checking, to inhibit machine start-up in the event of an internal
component failure. Both normally-open and normally-closed inputs are required. Multiple N.O. contacts can be wired in series
while multiple N.C. contacts can be wired in parallel.
|
|
|
|
 |
(800) 894-0412 (888) 723-4773 (Fax) info@clrwtr.com |
 HR1S-DMB/DME Series |
- 1NO-1NC safety input type, such as Magnetic Coded Safety Switches
- Fault diagnosis function with dual safety circuits
- Internal relay operations can be monitored with LED Indicator
- Finger-safe protection
- 22.5 or 45mm wide, 35mm DIN rail mounting
- EN ISO 13849-1 PLe, Safety Cat 4 compliant, and EN 62061 SIL 3
- UL listed, CSA certified, TÜV NORD approved
|
|
If you are looking for IDEC Safety Controller, please call us on
(800) 894 - 0412 or email us at
info@clrwtr.com
we will do our best to help you find the IDEC HR1S-DMB/DME Safety Relay that you are looking for at the most competitive prices
possible. If you are searching for IDEC FS1A-C01S Safety Controller technical information (data-sheets) please use the datasheets
or product selection guide page links.
|
 HR1S-AC Series |
- 1NC or 2NC safety input type, such as E-Stops or Interlock Switches
- EN ISO 13849-1 PLe, Safety Cat 3 compliant, and EN 62061 SIL 3
- Fault diagnosis function with dual safety circuits
- Internal relay operations can be monitored with LED Indicator
- Finger-safe protection
- 22.5mm wide, 35mm DIN rail mounting
- UL listed, CSA certified, TÜV NORD approved
|
 HR1S-AF Series |
- 2NC safety input type, such as E-Stops or Interlock Switches
- EN ISO 13849-1 PLe, Safety Cat 4 compliant, and EN 62061 SIL 3
- Welding detection of start switch
- Fault diagnosis function with dual safety circuits
- Internal relay operations can be monitored with LED Indicator
- Finger-safe protection
- 22.5mm wide, 35mm DIN rail mounting
- UL listed, CSA certified, TÜV NORD approved
|
 HR1S-ATE Series |
- EN ISO 13849-1 Performance Level e, Safety Category 4 compliant, and EN 62061 Safety Integrity Level 3
- Integrated and removable teminal styles available
- Compact design: 45 mm in width
- Time delay outputs: 3NO
- Auxiliary outputs enable monitoring of power, safety inputs, and a time delay output
- Environmentally friendly, RoHs directive compliant
- UL Listed, CSA certified, TÜV NORD approved.
|
 SafetyOne FS1A Series |
When you want a straightforward system that's safe, easy-to-use and won't cost an arm and a leg, a
SafetyOne FS1A safety controller is the answer!
Unlike a multiple safety relay system, which requires cumbersome wiring and take up too much space, or
safety PLCs that can be costly and difficult to program, our safety controllers make it easy to consolidate safety
circuits. At the same time they meet safety requirements, save space with minimal wiring and cost customers less money.
FS1A is UL listed, TUV rated and CE marked, as well as meets IEC 61508 integrity level 3, ISO 13849-1 performance level e
and EN954-1 safety category 4.
|
|
SafetyOne can replace up to six safety relay modules with no programming. Easily configure by turning on
a dip switch to 1 of 8 pre-difined logic circuits and one module can connect with various IDEC safety and non safety
components such as Emergency Stop switches, Interlock Switches, pilot lights, sensors and light curtains. With 7 dual
channel safety inputs, 4 safety outputs and multiple non safety inputs, monitor, blanking and solenoid drive outputs,
SafetyOne can simplify your complete safety and logic circuit.
Key Features
- No programming required
- Replaces up to six safety relay modules
- Just select a logic from eight pre-programmed circuits
- One module can connect with various types of safety inputs such as E-stop switches or light curtains
- Easily monitor logic circuit, I/Os and error codes with I/O LEDs and two 7 Segment LED display
- IEC 61508 integrity level 3, ISO 13849-1 performance level e and EN954-1 safety category 4 compliant
|
Our industrial factory automation supplies distributors warehouse in Boise, Idaho stocks some IDEC machine
safety products enabling us to further assist you in finding the correct FS1A-C11S controller for your application in the USA,
Canada and Mexico. Whether we have HR1S AC relays in stock in Boise, Idaho or need to get them from IDEC IZUMI to any USA cities;
Clearwater Tech can get HR1S DM DME relay to you fast and save money! It will be very helpful if you have the HR1S AF relay part
numbers ready, then our sales representatives can provide you with a pricing and availability quote for HR1S ATE relays that you
are looking for in seconds. If you do not have the part numbers for FS1A-C01S controllers, our application engineers will be able
to help you figure out the part numbers and get the price quote to you as soon as possible.
|
|
|
 |
|
| Part Number: |
|
|
Can't find a part number?
E-mail Us! |
|
|