P Series Push-in Terminal Blocks
Weidmuller introduces the new P Series terminal blocks with
push-in connection technology, designed to provide manufacturers with secure and reliable terminations, and achieve true savings.
Designed to reduce the number of Terminal Block variations
required, three P Series terminal blocks cover a cross section of 2.5mm2 to 16mm2 - a function previously requiring five
different blocks. A power supply terminal for electrical distribution applications is also available.
|
Novel Thermal Design Reduces Inverter Volume
Lenze has developed 8200 vector inverters using the 'cold plate' technique for cases where the inverter
can be mounted directly onto a substantial heatsink.
AC Tech Lenze 8200 vector inverters are available
for power 0.55 to 90kW with three-phase supply. In the more popular smaller sizes up to 22kW, a space saving variant can reduce the
requirement for panel space by up to 40%. By dissipating the heat outside the cabinet, these 'cold plate' versions enable panels to
have higher enclosure ratings. Alternatively a plate with external cooling by liquid or air can be used. The cold plate versions of
the 8200 vector inverters have no heat fins, so heat generated is passed to the mounting plate and transmitted out of the cabinet.
In this way inverters require less mounting depth and the space savings are substantial. For a 1.5kW inverter the saving is 25%,
rising to 40% for a 22kW inverter. |
 |
Therefore panels can be smaller and costs reduced. As the heat is now transmitted to outside of
the cabinet, requirements for a flow of cooling air through the cabinet are removed. Cabinets can be sealed and protection to IP65
is easier to achieve. This is particularly advantageous in dusty conditions where any through flow of air would cause a dust
build-up. Above 22kW the cold plate design is not available. However an alternative 'push-through' design can be used right up to
90kW. Here the Lenze Drives inverter heatsink is mounted
outside of the panel, gaining the advantages of panel space and enclosure as described. The concept of the 8200 vector frequency
inverter is based on a modular system of complementary components. Combined with a Lenze geared motor or a Lenze three-phase AC
motor, it can be used to implement electronic variable speed drives for a multiplicity of applications. Compact: Side-by-side
mounting saves space in the control cabinet. Integrated filters (optional) simplify installation. Flexible: The modular structure
enables the inverters to be optimised for your application. This results in cost-effective but high-performance drive solutions.
Whether as a "stand-alone" inverter with setpoint selection via potentiometer or a networked inverter with speed feedback in
master/slave mode, the inverter functions can be adapted to suit every application. |
|
|
|
Multifast Cordsets
Turck is now
offering the option to completely shield all molded M23 multifast cordsets by connecting a braided shield directly to the coupling
nut. This unique method of shielding provides a cost efficient and reliable home run connection with 100% cable and connector
shielding providing protection against electromagnetic and radio frequency interference. TURCK currently offers 7, 12 and 19-pin
cordsets with PVC flexlife cable jackets.
|
|
Pro-Face Xycom 12" Operator Interface
A great, first impression, multi-port
12 inch dedicated operator interface touch screen for OEMs and high graphical detail applications. The
Pro-Face Xycom
AGP3600 is part of a latest line of Pro-face brand operator interfaces. The bright, crisp, and clear SVGA display of this model is
complemented with a large viewing area, high resolution no-grid analog resistive touch screen providing a higher level of screen
clarity and precise part placement. A host of features include audio output, Ethernet, USB, RS232,422,485 serial ports, Direct MPI
support up to 12Mbps plus compatible with the GP2000-VM41 4 channel video mix module. Known for our network connectivity the
AGP3600 supports up to four simultaneous protocols making the AGP3600 a highly versatile operator interface. |
 |
Data logging and, trending, OEM field upgrades, recalling imported images
or capturing images from a video camera, are all possible with the APG3600
Xycom Operator Interface and a
CompactFlashTM card. Up to 512Mb storage Compact flash cards are optionally available. For data intensive applications with very
detailed graphic requirements, the AGP3600 is a great choice! For data intensive applications with very detailed graphic
requirements, the AGP3600 is a great choice! The AGP3000 is compatible with both types of bar code readers. Using these bar code .
data formats you can collect 84 to 1000 times more data than conventional bar-code readers. Bar code reader setup is easily
accomplished by one simple check box in GP PRO-EX HMI Development software. |
|
|
@ Clearwater Tech:
|
|
On-the-wall guide to circuit breaker selection
ABB Low Voltage Products has introduced three wallcharts to help take the
confusion out of circuit breaker selection. Containing comprehensive information including selection tables and calculations, the
charts explain how to size and select circuit breakers for transformer, generator and power factor correction applications. Each
chart includes detailed unit measurement tables to help match exact current, short circuit and overload current data to the
appropriate circuit breaker. The Power Factor Correction and Circuit Breaker Selection wallchart explains how to select circuit
breakers for capacitor bank switching and protection applications. By using the wallchart as a guide, users can match load
requirements against the data provided for ABB's TMax, Isomax and Emax circuit breakers to help them pick the best device for their
application. |
 |
The second wallchart, Circuit Breaker Selection for Protection and Switching of 400V
Transformers, explains how to select the appropriate type of circuit breaker for protection on the LV side of an MV-LV transformer.
Users can match their requirements against the wallchart's at-a-glance selection table, which shows the main
ABB Circuit Breaker options. Also included is advice for
consideration of other factors that can affect selection including selectivity and back-up protection. The third wallchart, Circuit
Breaker Selection for Generator Protection, covers the selection of circuit breakers for generator protection and switching
applications. The need to guarantee an ever greater continuity of service has led to an increase in the use of emergency supply
generators either to replace or supplement the public utility supply network. The wallcharts illustrate the main miniature circuit
breaker, moulded case circuit breaker and air circuit breaker options for generator protection applications up to 690V. |
|
|
|
|
If you wish to cancel your subscription to this newsletter, please Click Here. |