March 24, 2011
Entrelec Monitors
FANAL Low Voltage Monitors
(three phase and single phase) provide protection against premature equipment/motor failure caused by phase loss, phase
reversal, over or under voltage, unbalanced voltage, and short cycling. Dependable fault sensing with settable time
delay time delay and operation status indication.
|
NK Switches
The AS0 Series
low-current sensing swithces are specialized current operated switches that combine an ultra-sensitive current transformer and
signal conditioning electronics into a single package for sensing AC current from 3–350mA. Useful for signal or lamp status
monitoring, detecting minute fault currents or fan proving, the AS0 Series current sensing switches feature solid-state outputs
and jumper-selectable ranges,
|
|
|
|
 |
(800) 894-0412 (208) 368-0415 (Fax) info@clrwtr.com |
 PLM Series |
PLM Series - Plug-in Three Phase Voltage Monitor
- Protects Against: Phase Loss; Phase Reversal; Under and Unbalanced Voltages
- 3 Voltage Ranges 240, 380, or 480VAC
- Octal Plug-in Package - LED Indicator
- Adjustable Undervoltage Trip Point
- Fixed Unbalance and Trip Delay - Automatic Reset
- 10 Amps @ 240VAC SPDT Isolated Relay Contacts
- 1.78 x 2.39 x 3.2 Inches (45 x 61 x 81 mm)
- UL Recognized and CSA Certified
|
|
If you are looking for SSAC Voltage Monitors, please call us on
(800) 894 - 0412 or email us at
info@clrwtr.com
we will do our best to help you find the SSAC Motor Protectors that you are looking for at the most competitive prices
possible. If you are searching for SSAC Microcontroller Based Voltage Monitor technical information (data-sheets) please use
the datasheets or product selection guide page links.
|
 PLMU Series |
PLMU Series - Universal Plug-in Three Phase Voltage Monitor
- Protects Against: Phase Loss; Phase Reversal; Over, Under and Unbalanced Voltages
- Auto-Range Operates from 200 to 480VAC - Automatic Reset
- Protects Any Size 3 Phase Motor from 0.5 to 1200 Hp
- Octal Plug-in Package - Replaces Most Popular Plug-ins
- Bi-color LED Indicator Shows: Output Status, Faults, Time Delays
- Adjustable Line Voltage, Unbalance and Trip Delay
- 10 Amps @ 250VAC SPDT Isolated Relay Contacts
- 1.78 x 2.39 x 3.2 Inches (45.2 x 60.7 x 81.3 mm)
- UL Recognized, CSA Certified, CE Pending
|
 WVM Series |
WVM Series Three Phase Voltage Monitor
- Protects Against: Phase Loss; Phase Reversal; Under, Over, and Unbalanced Voltages; Short Cycling
- 10 Fault Non-Volatile Memory--LED Status Panel
- Operating Voltage from 200 to 600VAC, 4 Ranges
- Switch Selectable Manual Reset or Automatic Restart or Automatic with Restart Delay
- True 3 to 15 Second Random Start Delay
- Restart Delay 0.25 Second to 64 Minutes
- 6.9 x 4.4 x 2.4 Inches (175 x 112 x 61 mm)
- Terminal Block Connections
- Popular Part Numbers are In Stock
- UL Listed, CSA Certified, CE
|
 TVM Series |
TVM Series The Net Compact Voltage Monitor
- Protects Against: Phase Loss-Phase Reversal-Under, Over, and Unbalanced Voltages -Short Cycling
- Compact Low Cost OEM Design and Encapsulated Circuitry
- Fixed Operating Voltages from 208 to 480VAC
- Fixed, Over, Under, and Unbalanced Voltages, and Trip Delay
- 10 Amps @ 240VAC SPDT Isolated Relay Contacts
- 2 x 2 x 1.86 Inches (50.8 x 50.8 x 47.2 mm)
- 0.25 Inch (6.35mm) Male Quick Connect Terminals
- Automatic Reset - Bi-Color LED Indicator
- UL Recognized, CSA Certified, CE
|
 HLMU Series |
HLM Series Three Phase Voltage Monitor
- Protects Against: Phase Loss, Phase Reversal, Over, Under & Unbalanced Voltages, Over/Under Frequency
- Encapsulated Circuitry
- DPDT Isolated 10 A Contacts
- LED Indicates Relay Status, Faults, & Time Delays
- Universal Line Voltage
- 200 to 480 V AC in One Unit
- Compact, Encapsulated Design
- Finger-Safe Terminal Blocks, up to 12 AWG
- ASME A17.1 rule 210.6
- NEMA MG1 14:30, 14:35
- IEEE C62.41-1991 Level B
|
 TVW Series |
TVW Series The Net Compact Voltage Monitor
- Protects Against: Phase Loss-Phase Reversal-Under, Over, and Unbalanced Voltages -Short Cycling
- Compact Low Cost OEM Design and Encapsulated Circuitry
- Adjustable Operating Voltages from 208 to 480VAC in 2 Ranges
- Fixed, Over, Under, and Unbalanced Voltages, and Trip Delay
- 10 Amps @ 240VAC SPDT Isolated Relay Contacts
- 2 x 2 x 1.25 Inches (50.8 x 50.8 x 31.8 mm)
- 0.25 Inch (6.35mm) Male Quick Connect Terminals
- Automatic Reset - Bi-Color LED Indicator
- UL Recognized, CSA Certified, CE
|
 DLMU Series |
DLMU/DLMH Series - Three Phase Voltage Monitor
- Protects Against: Phase Loss; Phase Reversal; Under, Over and Unbalanced Voltages; Over/Under Frequency
- 50mm Package for Surface or 35mm DIN Rail Mounting
- DLMU - Universal Operating Voltage Range from 200 to 480VAC
- DLMH - Operating Voltage Range from 500 to 600VAC
- Cost Effective OEM Design - Encapsulated Circuitry
- Screw Terminals with Captive Clamps; IP20 Touch Proof
- Automatic Reset - Bi-Color LED Indicator
- Adjustable Line Voltage, Unbalance, Trip Delay and Restart Delay
- Adjustable Restart Delay from 0.6 to 300s Prevents Rapid Cycling
- 10 amp @ 240VAC SPDT Isolated Control Contacts
- 2 amp @ 240VAC N.O. or N.C. Isolated Alarm Contact
- Bi-Color LED Indicates: Relay status, Faults, & Time Delays
- 4.33 x 2.95 x 1.97 Inches (110 x 52 x 50 mm)
- UL Listed and CSA Certified, CE
|
 PLR Series |
PLR Series - Plug-in Three Phase Voltage Monitor
- Protects Against: Phase Loss (on startup), Phase Reversal, and Undervoltage
- Operating Voltage Ranges from 85 to 480VAC
- Exact Replacement for Popular Voltage Monitors
- Octal Plug-in Package - LED Indicator
- Adjustable Undervoltage Trip Point - Automatic Reset
- 5 Amps @ 240VAC SPDT Isolated Relay Contacts
- 1.78 x 2.39 x 3.2 Inches (45 x 61 x 81 mm)
- UL Recognized
|
 PLS Series |
PLS Series - Plug-in Three Phase Voltage Monitor
- Protects Against Phase Reversal - Relay energizes when phase sequence is correct
- Operating Voltage Ranges from 95 to 530VAC in 4 Ranges
- Octal Plug-in Package
- Automatic Reset
- 8 - 10 Amps @ 240VAC SPDT Isolated Relay Contacts
- 1.78 x 2.39 x 3.20 Inches (45 x 61 x 81 mm)
- UL Recognized and CSA Certified
|
 KVM Series |
Single Phase Undervoltage Monitor - KVM Series
- Protects Sensitive Equipment Against Undervoltage or Brownout Events
- Protects 110 to 120 V AC or 208 to 240 V AC Equipment
- Adjustable Undervoltage Trip Point
- 120 VAC Range: 78 to 99 V AC
- 240 VAC Range: 156 to 199 V AC
- 8 A, 1/3 hp SPDT Isolated Relay Contacts
- 0.25 in. (6.35mm) Male Quick Connect Terminals
- 2 x 2 x 1.2 in. (51 x 51 x 31mm)
- Encapsulated Circuitry
- UL Recognized, CSA Certified, CE Mark
|
 HLV Series |
Single Phase Undervoltage Monitor - HLV Series
- Protects Sensitive Equipment Against Undervoltage or Brownout Events
- 30 A, 1 hp SPDT Relay Contacts
- Universal Input Voltage 100 to 240 V AC
- Adjustable Undervoltage Trip Point
- 120 VAC Range: 70 to 120 V AC
- 240 VAC Range: 170 to 220 V AC
- Adjustable Restart Delay 3 to 300 s
- Fixed Trip Delay of 1 to 20 s
- 0.25 in. (6.35mm) Male Quick Connect Terminals
- 2 x 3 x 1.5 in. (77 x 51 x 38mm)
- Encapsulated Circuitry
- UL Recognized, CSA Certified, CE Mark
|
|
Our SymCom distributors warehouse in Boise, Idaho USA stocks some SymCom products enabling us to further
assist you in finding the correct ABB SSAC three-phase voltage monitor in the USA, Canada and Mexico. Whether we have SSAC
3-Phase voltage monitor in stock in Boise, Idaho USA or need to ship direct from SymCom to any USA cities; Clearwater Tech
can get entrelec SSAC microcontroller based motor protectors to you fast and save you some money! It will be very helpful if
you have the SSAC voltage monitors part numbers ready, then our sales representatives can provide you with a pricing and
availability quote for SSAC 1-phase voltage monitor that you are looking for in seconds. If you do not have the part numbers
for ABB voltage monitors, our application engineers will be able to help you figure out the part numbers and get the price
quote to you as soon as possible.
|
|
|
|
 |
|
| Part Number: |
|
|
Can't find a part number?
E-mail Us! |
|
|