June 28, 2011
Banner Safety Controller
The Banner Models SC22-3/SC22-3E Safety Controller
are easy-to-use, configurable, 24V dc safety modules designed to monitor multiple safety and non-safety input devices and
control up to three independent machine primary control elements (MPCEs). They provide safety stop and start functions for
machines with hazardous motion. The Safety Controller can replace multiple safety relay modules in applications that
include such safety input devices
|
CONTRINEX Mirror Columns
The Mirror Columns YXC
are used for the beam deflection of safety light curtains and access control barriers, such as Safetinex YBB and YCA models,
in order to achieve multi-sided safeguarding of danger zones, while eliminating the need for additional light curtains or
access control barriers. Spring elements at the base of the column provide for automatic reset following mechanical impact.
|
|
|
|
 |
(800) 894-0412 (888) 723-4773 (Fax) info@clrwtr.com |
 SF-C10 Series |
- Quick-connection - Connecting to the light curtain is done using plug-in connections, which shortens setup and
replacement time.
- Easy setup requiring no torque control - A spring method is used for the terminal blocks for connections other than
to the light curtain. There is no need to control tightening torques for these terminal blocks.
- Removable terminal blocks reduce maintenance time - Removable terminal blocks are used. This reduces the work required
for reconnecting wiring during maintenance.
|
|
If you are looking for SUNX Safety Light Control Units, please call us on
(800) 894 - 0412 or email us at
info@clrwtr.com
we will do our best to help you find the SUNX Exclusive Control Unit for Light Curtain SF-C10 that you are looking for at the
most competitive prices possible. If you are searching for SUNX CC-Link Safety System Remote I/O Unit for Light Curtain
SF-CL1T264T technical information (data-sheets) please use the datasheets or product selection guide page links.
|
 SF-C11 Series |
SF-C11 Connector Connection Type Control Unit
- Removable terminal blocks are used. This reduces the work required for reconnecting wiring during maintenance.
- Use 8-core cable with connector to connect to the light curtain.
- Compatible with up to control category 4.
- Interference prevention wires and muting function cannot be used.
- Light curtain connection cable:
- SFB-CB
- (For SF4B series)
- SF2B-CCB
- (For SF2B series)
- Extension cable: SFB-CCJ10
|
 SF-C12 Series |
SF-C12 Robust Type Control Unit
- Use 12-core cable with connector to connect to the light curtain.
- Interference prevention wires can be used.
- Compatible with up to control category 4.
- Muting function cannot be used.
- Light curtain connection cable: SFB-CB05-MU
- Extension cable: SFB-CCJ10-MU
|
 SF-C13 Series |
SF-C13 Slim Type Control Unit
- Slim design - 22.5 mm 0.886 in thickness, so can be inserted even into narrow spaces inside panels.
- Use a discrete wire cable to connect to the light curtain.
- Muting function and interference prevention wires can be used.
- Compatible with up to control category 4.
- Light curtain connection cable:
- SFB-CCB (-MU)
- (For SF4B series)
- SF2B-CCB
- (For SF2B series)
- Extension cable: SFB-CC (-MU)
|
 SF-C14EX Series |
When SUNX SF4B series of light curtains is used, the muting control circuit can be built at low cost. The
newly-released SF-C14EX application expansion unit allows the light curtain, muting sensors and muting indicators to be
connected together directly, so that muting control circuits can be built very easily.
Three safety circuit systems can be controlled independently so that equipment can be stopped all together
or partially.
High-speed response 14 ms - Avoids the response delays that occur when using more than one safety relay
unit, and greatly reduces the light curtain safety distance and improves ease of working.
|
 SF-C14EX-01 Series |
SF-C14EX-01 Application Expansion Unit for the SF4B Series
- The muting control function and emergency stop input are equipped, expanding the applications of the light curtains.
- It can be connected to the light curtains using the exclusive connection cable.
- Compatible with up to control category 4.
- Light curtain connection cable: SFB-CB-EX
- Extension cable: SFB-CCJ10
|
 SF-CL1T264T |
In addition to light curtains, peripheral I/O units such as safety components can also be connected to
CC-Link safety system remote I/O unit SF-CL1T264T so that safety circuit signals can all be transmitted to CC-Link Safety
and be centrally controlled. Up to two sets of the SF4B series of light curtains can be easily connected using connectors.
(If a terminal block is used, more than two sets can be connected.) The terminal block can be installed and removed with the
cables still attached, the man-hours required for maintenance is greatly reduced. Light curtain muting can also be controlled
by means of a program, so that the line will only stop when a person passes through, and will not stop when a workpiece
passes through.
|
|
Our industrial factory automation supplies distributors warehouse in Boise, Idaho stocks some SUNX products
enabling us to further assist you in finding the correct SUNX SF-C14EX-01 for your application in the USA, Canada and Mexico.
Whether we have SUNX SF-C12 in stock in Boise, Idaho or need to ship direct from Panasonic to any USA cities; Clearwater Tech
can get SUNX SF-CL1T264T to you fast and save some money! It will be very helpful if you have the SUNX SF-C14EX part numbers
ready, then our sales representatives can provide you with a pricing and availability quote for SUNX SF-C10 that you are
looking for in seconds. If you do not have the part numbers for SUNX control units for safety light curtains, our application
engineers will be able to help you figure out the part numbers and get the price quote to you as soon as possible.
|
|
|
|
 |
|