The 2800T series magnetic contacts are designed for high-security hazardous environments.

The rugged die-cast aluminum housing with conduit fittings meets UL requirements for hazardous locations.

Sentrol Industrial 2804T 2807T 2808T High Security Explosion Proof Magnetic Contacts Distributors

2800T Series

Instruction Manual

The contacts are balanced, triple-biased, SPDT switches that make defeat by external magnets virtually impossible. The contacts feature tamper circuits that are actuated by removal of the face plate or by introduction of an external magnet.

The terminals are located inside the housing, providing additional protection from tampering or accidental shorting. Optional features include pry tamper loop for alarm in case of contact removal, current limiting device for circuit protection, and heavy-duty housings.

If you are looking for GE Sentrol 2800 Series Magnetic Contacts, please call us on (844) 331-9374 or email us at info@clrwtr.com we will do our best to help you find the GE Interlogix 2814T Position Sensors that you are looking for at the most competitive prices possible. If you are searching for Sentrol Industrial 2808T Explosion-Proof Contact technical information (data-sheets) please use the datasheets or product selection guide page links.

Sentrol 2810T Series Surface Mount Maximum-Security Magnetic Contacts with Terminals Distributor

2810T Series

Instruction Manual

The 2810T series magnetic contacts are designed for maximum security applications. Rugged die-cast aluminum housing with conduit fittings protect contacts that are balanced and triple-biased to make defeat by external magnets virtually impossible.

Each contact features a tamper loop with sensitive reed switch for additional magnetic field protection and a tamper switch for the lid. The terminals are located inside the housing, providing additional protection from tampering or accidental shorting. Matched and serialized sets ensure optimum operation and reduce false alarms.

Sentrol 2840T Series Surface Mount Explosion-Proof Conduit Contacts with Terminals Distributors

2840T Series

Instruction Manual

The 2840T series magnetic contacts are designed for high-security hazardous environments. The rugged die-cast aluminum housing with conduit fittings meets UL requirements for hazardous locations. The contacts are balanced and triple-biased switches that make defeat by external magnets virtually impossible.

The terminals are located inside the housing, providing additional protection from tampering or accidental shorting. A wider gap model protects against false alarms due to loose-fitting doors and permits faster installation.

Our industrial factory automation supplies distributors warehouse in Boise, Idaho stocks some Sentrol Industrial products enabling us to further assist you in finding the correct 2847T magnetic contact for your application in the USA, Canada and Mexico. Whether we have 2847TH contact in stock in Boise, Idaho or need to ship direct from UTC Fire & Security to any USA cities; Clearwater Tech can get 2804T contact to you fast and save money! It will be very helpful if you have 2807T contact part numbers ready, then our sales representatives can provide you with a pricing and availability quote for 2817T terminal contact that you are looking for in seconds. If you do not have the part numbers for 19443-M L bracket for 2800 series contacts, our application engineers will be able to help you figure out the part numbers and get the price quote to you as soon as possible.

Stock Check

Part No:
OR
Manufacturer:

Search Tips
Can't find a part number?
E-mail Us!

SSAC Controls

When Connected to a Site monitoring system, this unit provides the remote beacon monitoring protection required by the FAA/FCC. On a multiple beacon structure, one unit is required for each two-lamp incandescent beacon (one unit per beacon for LED beacons). If one lamp in an incandescent beacon fails, the relay and solid-state lamp failure outputs energize after 10s. If the flasher fails in the ON or OFF condition,

SEW Eurodrive

A Major Criterion for designing units intended for use in explosive dust areas is, among others, the compliance with certain IP degrees of protection (protection against ingress of foreign particles according to EN 60259). Category 3 electrical units must comply with at least IP54, category 2 units at least with IP6x. SEW-EURODRIVE carried out the approval of motors for