Non-Ventilated 50 VA to 45 kVA
Loading
1-Phase & 3-Phase Buck-Boost
Drive Isolation

ABB Drives

The Multidrive Principle is based on a standard DC bus arrangement enabling single power entry and common braking resources for several drives. There are several possibilities on the supply side starting from a simple diode supply unit up to highly sophisticated IGBT supply units. ACS800-X4 units are complete single drive module products that are optimised for assembly in customers' own cabinets. The ACS800-X4 is designed to minimise

Weidmuller Power Supply

The New Connect Power PROmax power supplies offer a wide range of robust solutions for demanding application requirements. Designed for high performance and durability, PROmax switchmode power supply units reliably provide continuous overload currents of up to 120%, or supply short-term peak loads up to 300% of nominal power. Features include high output power boost capability and maximum power within a wide operating temperature range.

Sola Hevi Duty

Home   >   Products   >   Sola HD  >   Automation   >   Transformers

Sola Hevi Duty

(800) 894-0412       (888) 723-4773 (Fax)
info@clrwtr.com

SolaHD Non-Ventilated 50 VA To 45 kVA Automation Transformers Distributor
Non-Ventilated 50 VA To 45 kVA

Hevi-Duty encapsulated transformers are rated for Hazardous Locations (Class 1, Division 2, Group A-D) as well as harsh industrial environments. Encapsulation and rugged NEMA 3R enclosures protect the transformer from dust, moisture, and provide extra shock and vibration resistance. Hevi-Duty UL listed transformers fully comply with the latest addition of the National Electrical Code for Class 1, Division 2, Group A-D locations when installed in compliance with NEC 501-2(b).

  • UL-3R non encapsulated enclosure for indoor and outdoor service
  • Low temperature rise, UL Class 130oC or 180oC insulation system, 80oC temperature rise under full load
  • Conduit knockouts for side entry into wiring compartment
  • Copper lead wire terminations

If you are looking for Sola Automation Transformers, please call us on (800) 894 - 0412 or email us at info@clrwtr.com we will do our best to help you find the Non-Ventilated General Purpose Transformer that you are looking for at the most competitive prices possible. If you are searching for Buck-Boost Transformer technical information (data-sheets) please use datasheets or product selection guide page links.

SolaHD Buck-Boost Single-Phase Three-Phase Dry-Type Distribution Transformers Distributor
1-Phase & 3-Phase Buck-Boost

Sola/Hevi-Duty buck-boost transformers are designed to supply power to low voltage lighting circuits, control panels or other systems requiring 12, 16, 24, 32, or 48 Volts. When connected as an insulating transformer, the transformer's capacity matches the nameplate KVA rating. Sola Hevi-Duty buck-boost transformers are also suited for low voltage landscape lighting. They are UL listed for outdoor service and their compact size makes them the perfect solution for providing power to accent lighting applications. When using dimmers for low voltage applications, use only dimmers designed and rated for use with magnetic loads.

SolaHD 7.5 To 440 kVA Three Phase Drive Isolation Transformers Distributor
Drive Isolation

Sola Hevi-Duty drive isolation transformers are specifically designed to handle the mechanical stresses, voltage demands and harmonics associated with SCR applications.

  • Available from 7.5 thru 440 KVA, 3 Phase, 60 Hz
  • Isolation minimizes load disturbances caused by the SCR drive
  • UL-3R enclosures when used with optional weather shield
  • Taps on all units for adjustments to incoming source voltage. Full capacity secondary neutral as required by the National Electric Code.
  • Shielding attenuates line to ground noise
  • 10+2 year Sola/Hevi-Duty warranty
SolaHD SBE Encapsulated Series Industrial Control Transformers Distributor
Industrial Control

The SBE series (encapsulated and open style) Sola transformer is available from 50 - 5000 VA, 55°C Rise and features copper windings and encapsulation (through 1000 VA) for longer life and protection from the environment.

  • 55°C Rise, 105°C Insulation to Minimize Heat
  • 10-20% More VA Capacity
  • Superior Voltage Regulation
  • UL Listed and CSA Certified
  • Rated for 50 or 60 Hz Use
  • Epoxy Encapsulated Design
Sola Hevi Duty HSZ Series Industrial Control Transformers Distributor
Hazardous Location

Sola/Hevi-Duty's encapsulated transformers are suited for harsh industrial use as well as for Hazardous Location (Class 1, Division 2, Group A-D) and harsh industrial environments.

  • Broad Line: Single Phase: 0.5 KVA - 25 KVA OR Three Phase: 3 KVA - 45 KVA
  • UL Class 180°C insulation system, 115 °C temperature rise under full load
  • Available in cold rolled steel or painted stainless steel enclosures
  • NEMA 3R outdoor enclosures standard
  • Shielded for quality power on sizes 1 KVA and above
  • Available in NEMA 12 or 4X enclosures

Our industrial factory automation supplies distributors warehouse in Boise, Idaho stocks some Sola Heavy-Duty products enabling us to further assist you in finding the correct Non-Ventilated Transformer for your application in the USA. Whether we have Buck-Boost Transformers in stock in Boise, Idaho or need to ship direct from Sola Hevi Duty to any USA cities; Clearwater Tech can get Hazardous Location Transformer to you fast and save you money! It will be very helpful if you have the Sola Automation Transformer part numbers ready, then our sales representatives can provide you with a pricing and availability quote for Non-Ventilated General Purpose Transformers that you are looking for in seconds. If you do not have the part numbers for Drive Isolation Transformer, our application engineers will be able to help you figure out the part numbers and get the price quote to you as soon as possible.

Hazardous Location
Part Number:
Manufacturer:

Search Tips

Can't find a part number?
E-mail Us!

Encapsulated Transformer
Open Style Transformers
Industrial Control