Hammond Transformer
Hammond
offers a variety of dry-type transformers and reactors that no other transformer manufacturer can match. With six plants
located throughout North America, we have expanded our manufacturing and product base to offer you the broadest range of
both standard and special reactors, control and dry-type transformers anywhere.
DC Filter Chokes
|
Weidmuller Power Supply
Diode Module for Decoupling Outputs
of switched-mode power units. Switched-mode power units have a disadvantage when multiple secondary circuits are switched in
parallel, an opposite negative influence can effect the individual circuit. This can damage the devices. The CP DM diode modules
can help here. They are used for doubling the output, redundancy operation, supplying critical loads and protecting against
energy recovery.
|
|
|
|
 |
(800) 894-0412 (888) 723-4773 (Fax) info@clrwtr.com |
 Non-Ventilated 50 VA To 45 kVA |
Hevi-Duty encapsulated transformers are rated for Hazardous Locations (Class 1, Division 2, Group A-D)
as well as harsh industrial environments. Encapsulation and rugged NEMA 3R enclosures protect the transformer from dust,
moisture, and provide extra shock and vibration resistance. Hevi-Duty UL listed transformers fully comply with the latest
addition of the National Electrical Code for Class 1, Division 2, Group A-D locations when installed in compliance with NEC
501-2(b).
- UL-3R non encapsulated enclosure for indoor and outdoor service
- Low temperature rise, UL Class 130oC or 180oC insulation system, 80oC temperature rise under full load
- Conduit knockouts for side entry into wiring compartment
- Copper lead wire terminations
|
|
If you are looking for Sola Automation Transformers, please call us on
(800) 894 - 0412 or email us at
info@clrwtr.com we
will do our best to help you find the Non-Ventilated General Purpose Transformer that you are looking for at the most competitive
prices possible. If you are searching for Buck-Boost Transformer technical information (data-sheets) please use datasheets or
product selection guide page links.
|
 1-Phase & 3-Phase Buck-Boost |
Sola/Hevi-Duty buck-boost transformers are designed to supply power to low voltage lighting circuits,
control panels or other systems requiring 12, 16, 24, 32, or 48 Volts. When connected as an insulating transformer, the
transformer's capacity matches the nameplate KVA rating. Sola Hevi-Duty buck-boost transformers are also suited for low voltage
landscape lighting. They are UL listed for outdoor service and their compact size makes them the perfect solution for providing
power to accent lighting applications. When using dimmers for low voltage applications, use only dimmers designed and rated for
use with magnetic loads.
|
 Drive Isolation |
Sola Hevi-Duty drive isolation transformers are specifically designed to handle the mechanical stresses,
voltage demands and harmonics associated with SCR applications.
- Available from 7.5 thru 440 KVA, 3 Phase, 60 Hz
- Isolation minimizes load disturbances caused by the SCR drive
- UL-3R enclosures when used with optional weather shield
- Taps on all units for adjustments to incoming source voltage. Full capacity secondary neutral as required by the National
Electric Code.
- Shielding attenuates line to ground noise
- 10+2 year Sola/Hevi-Duty warranty
|
 Industrial Control |
The SBE series (encapsulated and open style) Sola transformer is available from 50 - 5000 VA, 55°C Rise
and features copper windings and encapsulation (through 1000 VA) for longer life and protection from the environment.
- 55°C Rise, 105°C Insulation to Minimize Heat
- 10-20% More VA Capacity
- Superior Voltage Regulation
- UL Listed and CSA Certified
- Rated for 50 or 60 Hz Use
- Epoxy Encapsulated Design
|
 Hazardous Location |
Sola/Hevi-Duty's encapsulated transformers are suited for harsh industrial use as well as for Hazardous
Location (Class 1, Division 2, Group A-D) and harsh industrial environments.
- Broad Line: Single Phase: 0.5 KVA - 25 KVA OR Three Phase: 3 KVA - 45 KVA
- UL Class 180°C insulation system, 115 °C temperature rise under full load
- Available in cold rolled steel or painted stainless steel enclosures
- NEMA 3R outdoor enclosures standard
- Shielded for quality power on sizes 1 KVA and above
- Available in NEMA 12 or 4X enclosures
|
Our industrial factory automation supplies distributors warehouse in Boise, Idaho stocks some Sola Heavy-Duty products enabling us
to further assist you in finding the correct Non-Ventilated Transformer for your application in the USA. Whether we have
Buck-Boost Transformers in stock in Boise, Idaho or need to ship direct from Sola Hevi Duty to any USA cities; Clearwater Tech
can get Hazardous Location Transformer to you fast and save you money! It will be very helpful if you have the Sola Automation
Transformer part numbers ready, then our sales representatives can provide you with a pricing and availability quote for
Non-Ventilated General Purpose Transformers that you are looking for in seconds. If you do not have the part numbers for Drive
Isolation Transformer, our application engineers will be able to help you figure out the part numbers and get the price quote to
you as soon as possible.
|
|
|
 |
|
| Part Number: |
|
|
Can't find a part number?
E-mail Us! |
|
|