April 12, 2010
Hammond Transformer
Isolation Transformers
are used for maximum safety, versatility (can be used on both electrical & electronic equipment) and isolation from the
power source, used to step-up, step-down or for straight isolation. The disadvantage to using them is weight (about double
the "Auto"), more expensive and larger size. This type of transformer is sometimes referred to as "double-wound".
PCB Mount
|
NK CTs
NK ProteCT Series
current transformers are intended for use with APT and APO/APN series power transducers, ProtectCT low voltage output current
transformers provide easy sensing of current on three-phase applications with the added safety of a 333mV output
secondary.
Low-Voltage 3-Phase
|
|
|
|
 |
(800) 894-0412 (208) 368-0415 (Fax) info@clrwtr.com |
 Distribution |
The Energy Policy Act of 2005 (H.R. 6) requires Distribution Transformers manufactured after
January 1, 2007 to meet specific energy efficiency requirements. EPAct 2005 defines the term "distribution transformers" as
any transformer which:
- Has an input voltage of 34.5 kV or less
- Has an output voltage of 600 V or less
- Is rated for operation at a frequency of 60 Hz
- Has a capacity of 10 kVA to 2500 kVA for liquid-immersed units and 15 kVA to 2500 kVA for dry-type units
|
|
If you are looking for Sola Transformers, please call us on
(800) 894 - 0412 or email us at
info@clrwtr.com we
will do our best to help you find the Constant Voltage Transformer that you are looking for at the lowest prices possible.
If you are searching for Automation Transformer technical information (data-sheets) please use the
SolaHD Transformer Datasheets or
Product Selection Guide page links.
|
 Automation |
Hevi-Duty encapsulated transformers are rated for Hazardous Locations (Class 1, Division 2, Group A-D)
as well as harsh industrial environments. Encapsulation and rugged NEMA 3R enclosures protect the transformer from dust,
moisture, and provide extra shock and vibration resistance. Hevi-Duty UL listed transformers fully comply with the latest
addition of the National Electrical Code for Class 1, Division 2, Group A-D locations when installed in compliance with NEC
501-2(b).
|
 Industrial Control |
The SBE series (encapsulated and open style) Sola transformer is available from 50 - 5000 VA, 55°C Rise
and features copper windings and encapsulation (through 1000 VA) for longer life and protection from the environment.
- 55°C Rise, 105°C Insulation to Minimize Heat
- 10-20% More VA Capacity
- Superior Voltage Regulation
- UL Listed and CSA Certified
- Rated for 50 or 60 Hz Use
- Epoxy Encapsulated Design
|
 Hazardous Area |
Sola/Hevi-Duty's encapsulated transformers are suited for harsh industrial use as well as for Hazardous
Location (Class 1, Division 2, Group A-D) and harsh industrial environments.
- Broad Line: Single Phase: 0.5 KVA - 25 KVA OR Three Phase: 3 KVA - 45 KVA
- UL Class 180°C insulation system, 115 °C temperature rise under full load
- Available in cold rolled steel or painted stainless steel enclosures
- NEMA 3R outdoor enclosures standard
- Shielded for quality power on sizes 1 KVA and above
- Available in NEMA 12 or 4X enclosures
|
 MCR Hardwired Series |
The MCR Hardwired Series constant voltage transformer provides excellent noise filtering and surge
suppression to protect connected equipment from damage, degradation or misoperation.
- VA Ratings: 120 to 15,000 VA. Input Voltage Range: +10/-20% of nominal
- ±3% output voltage regulation
- Acts as a step-up or step-down transformer
- Galvanic isolation provides exceptional circuit protection
- 25 year typical MTBF (Mean Time Before Failure)
- Noise Isolation: 120 dB common mode; 60 dB normal mode
- Surge Suppression: Up to 6,000 Volt surges
|
 Drive Isolation |
Sola Hevi-Duty drive isolation transformers are specifically designed to handle the mechanical stresses,
voltage demands and harmonics associated with SCR applications.
- Available from 7.5 thru 440 KVA, 3 Phase, 60 Hz
- Isolation minimizes load disturbances caused by the SCR drive
- UL-3R enclosures when used with optional weather shield
- Taps on all units for adjustments to incoming source voltage. Full capacity secondary neutral as required by the National
Electric Code.
- Shielding attenuates line to ground noise
- 10+2 year Sola/Hevi-Duty warranty
|
 CVS Hardwired Series |
Superior voltage regulation of ±1% sets the CVS Series Sola constant voltage transformers apart from other
power conditioning technologies on the market.
- VA Ratings: 30 to 7,500 VA. Input Voltage Range: +10/-20% of nominal
- Output Harmonic Distortion: 3% total RMS content at full load
- Noise Isolation: 40 dB common and normal mode
- Surge Suppression: Up to 6,000 Volt surges are suppressed to safe levels per ANSI/IEEE C62.41-1980 Class A and B
waveforms.
- Operating Temperature: -20°C to +50°C
- Acts as a Step-up/Step-down Transformer
- No maintenance required
|
 Low Temperature Rise |
Sola Hevi-Duty's low temperature rise transformers feature a 220°C insulation system and temperature rise
of only 80°C or 115°C under full nameplate load. The result is 13-21% lower operating losses than conventional 150°C rise
units.
- Shielded for quality power
- UL-3R outdoor enclosure with optional weather shield
- Thermal reserve allows for continuous overload operation at 150°C rise
- Aluminum windings for greater insulation life
- Class 220°C insulation system, 115°C or 80°C rise
- Single and three phase availability
|
 Buck-Boost |
Sola/Hevi-Duty buck-boost transformers are designed to supply power to low voltage lighting circuits,
control panels or other systems requiring 12, 16, 24, 32, or 48 Volts. When connected as an insulating transformer, the
transformer's capacity matches the nameplate KVA rating. Sola Hevi-Duty buck-boost transformers are also suited for low voltage
landscape lighting. They are UL listed for outdoor service and their compact size makes them the perfect solution for providing
power to accent lighting applications. When using dimmers for low voltage applications, use only dimmers designed and rated for
use with magnetic loads.
|
| Part Number |
Primary |
Secondary |
VA Rating |
Input Hz |
| E500 |
220V x 480V |
110V x 120V |
500 |
50/60 Hz |
| E100 |
220V x 480V |
110V x 120V |
100 |
50/60 Hz |
| E050 |
220V x 480V |
110V x 120V |
50 |
50/60 Hz |
| E1000 |
220V x 480V |
110V x 120V |
1000 |
50/60 Hz |
| E150 |
220V x 480V |
110V x 120V |
150 |
50/60 Hz |
| E250 |
220V x 480V |
110V x 120V |
250 |
50/60 Hz |
| E050E |
120V x 240V |
24V |
50 |
60 Hz |
| E100E |
120V x 240V |
24V |
100 |
60 Hz |
| E150E |
120V x 240V |
24V |
150 |
60 Hz |
| 23-13-060-2 |
120V |
120V |
60 |
60 Hz |
| 63-23-150-8 |
120V x 480V |
120V x 240V |
500 |
60 Hz |
| 63-23-215-8 |
120V x 480V |
120V x 240V |
1500 |
60 Hz |
| E075E |
120V x 240V |
24V |
75 |
60 Hz |
| E200 |
220V x 480V |
110V x 120V |
200 |
50/60 Hz |
| E075 |
220V x 480V |
110V x 120V |
75 |
50/60 Hz |
Our Sola Transformer Distributors warehouse in Boise, Idaho stocks some Sola Hevi Duty products enabling us
to further assist you in finding the correct Auto Transformer for your application in the USA. Whether we have Distribution
Transformer in stock in Boise, Idaho or need to ship direct from any Sola Hevi Duty warehouse (Memphis Tennessee, Rainsville
Alabama & Fullerton California) to any USA cities; Clearwater Tech can get Industrial Control Transformer to you fast and
save you money! It will be very helpful if you have the Sola Hevi Duty Transformer part numbers ready, then our sales
representatives can provide you with a pricing and availability quote for Constant Voltage Transformers that you are looking
for in seconds. If you do not have the part numbers for Isolation Transformer, our application engineers will be able to help
you figure out the part numbers and get the price quote to you as soon as possible.
|
|
|
 |
|
| Part Number: |
|
|
Can't find a part number?
E-mail Us! |
|
|