ISS-100
ISS-101
ISS-102A-LC
ISS-102AA-DCS

SEW Gearmotors

The PS.F Series planetary servo gear units are available in eight sizes with acceleration torques of up to 4,200 Nm. PS.F planetary servo gear units are available in three drive versions: Solid shaft (PS.F), solid shaft with key (PSK.F) and flange block shaft (PSB.F). You also have the option of three circumferential backlash classes: Standard > 6', reduced < 3' and minimized < 1'. SEW-EURODRIVE offers one of the most powerful

TURCK Transducers

When no Metal is being sensed, the inductive sensor is in a low impedance state and draws a current of more than 2.2 mA. When a metal target enters the high-frequency field radiated from the sensor head, the impedance increases as the target approaches. When fully damped, the sensor draws less than 1.0 mA. Note: For capacitive and inductive magnet operated sensors, the current change characteristics are opposite.

SymCom

Loading

Home   >   Products   >   SymCom   >   Intrinsically Safe Switches

SymCom

(800) 894-0412       (888) 723-4773 (Fax)
info@clrwtr.com

SymCom MotorSaver Model ISS-100 Intrinsically Safe Isolated Switches Distributors
Model ISS-100

SymCom Model ISS-100 isolated switch is UL 913 listed as an associated apparatus for interfacing between hazardous and non-hazardous areas. The ISS-100 must be installed in a non-hazardous area.

Features:

  • UL 913 listed
  • Compact Design
  • Finger safe terminals
  • DIN rail or surface mountable
  • LED state indicator
  • Isolated output relay for PLC or control voltage

If you are looking for SymCom Intrinsically Safe Relays, please call us on (800) 894 - 0412 or email us at info@clrwtr.com we will do our best to help you find the SymCom Intrinsically Safe Switches that you are looking for at the most competitive prices possible. If you are searching for SymCom Intrinsically Safe Controllers technical information (data-sheets) please use the datasheets or product selection guide page links.

SymCom Motor Saver Model ISS-101 Intrinsically Safe Relays Distributor
Model ISS-101

SymCom Model ISS-101 is a plug-in style isolated switch, is UL 913 listed as an associated apparatus for interfacing between hazardous and non-hazardous areas. The ISS-101 must be installed in a non-hazardous area.

Features:

  • UL 913 listed
  • Compact Design
  • Finger safe terminals
  • DIN rail or surface mountable
  • LED state indicator
  • Isolated output relay for PLC or control voltage
SymCom Model ISS-102ACI-MC Intrinsically-Safe Multi-function Controller Distributor
ISS-102 Series

Model ISS-102

SymCom's Model ISS-102 two-channel, intrinsically-safe switch is designed for multiple uses including a pump-up/pump-down (latching) controller or two-channel switch. Two LEDs indicate the state of the intrinsically-safe inputs and output relays and user-selectable options are available including a variable resistance threshold for float inputs.The ISS-102 enclosure is surface mountable but is also compatible with DIN rail (35mm).

-LC Each input channel is active when the corresponding switch is closed. When the lag input (CH2) is activated, the output closes. -DCS This dual-channel switch has a debounce delay feature of 0.5 seconds. -MC By selecting the proper functionality through the dip switches, you can define a pump-up or pump-down, single or dual channel non-latching switch.

SymCom PumpSaver Model ISS-105 Intrinsically Safe Switch Distributor
Model ISS-105

SymCom ISS-105 IS Super Cell is a "smart" five-channel intrinsically safe relay and pump controller. The IS Super Cell can be configured for a wide variety of applications including alternating or non-alternating duplex, duplex separate pump stop (SPS), triplex, and quadplex applications. It can be set up for pump up or pump down applications or can be used as a five-channel relay. The IS Super Cell can indicate low, high and out-of-sequence alarms. If an out-of-sequence alarm occurs, the skipped pump(s) will be started as intended. The IS Super Cell can start an emergency pump once every 50 cycles to keep it working freely. Using the built-in DIP switches, individual pumps can be disabled when taken out of service for repair or maintenance.

SymCom PumpSaver Model ISS-105-ISO, ISS-105-ISO-3 & ISS-105-ISO-4 Intrinsically Safe Switches Distributors
Model ISS-105-ISO, ISS-105-ISO-3 & ISS-105-ISO-4

The Model ISS-105-ISO is a 5-channel intrinsically-safe relay switch suitable for applications with switch inputs in hazardous locations. The five channels operate independently of each other and each input and output relay has an LED that illuminates when the corresponding input and output relay activates. The relay logic can be inverted from positive to negative logic, meaning the output relay will close (positive logic) when the corresponding input closes, or the output relay will open (negative logic) when the corresponding input closes (channels cannot be inverted independently).

The Model ISS-105-ISO comes as a basic 5-channel relay, however three modified versions are available. The ISS-105-ISO-3 is for 3-channel applications and the ISS-105-ISO-4 is for 4-channel applications.

SymCom Model ISS-105-ISO-F Pump Saver Intrinsically Safe Relays Distributor
Model ISS-105-ISO-F

the ISS-105-ISO-F is for 5-channel applications requiring a faster relay response time after the input is actuated. The ISS-105-ISO-F relay, powered by 120VAC, is an isolated switch suitable for applications with switch inputs in a hazardous location. In a powered state, the ISS-105-ISO-F will actuate each output relay within .75 second of the corresponding input switch closing/opening (dependent on positive/negative logic mode). Each red LED illuminates when the corresponding output relay is energized. Each green LED illuminates when the corresponding input is closed.

Our industrial factory automation supplies distributors warehouse in Boise, Idaho USA stocks some SymCom products enabling us to further assist you in finding the correct SymCom isolated switches in the USA, Canada and Mexico. Whether we have SymCom latching controllers in stock in Boise, Idaho USA or need to ship direct from SymCom to any USA cities; Clearwater Tech can get MotorSaver ISS-105-ISO-4 5-channel intrinsically-safe relay switch to you fast and save you some money! It will be very helpful if you have the SymCom ISS-105-ISO-F part numbers ready, then our sales representatives can provide you with a pricing and availability quote for ISS-102C-M-LC switch that you are looking for in seconds. If you do not have the part numbers for SymCom ISS-102CCI-M-MC, our application engineers will be able to help you figure out the part numbers and get the price quote to you as soon as possible.

ISS-102ACI-MC
Part Number:
Manufacturer:

Search Tips

Can't find a part number?
E-mail Us!

ISS-105
ISS-105-ISO
ISS-105-ISO-3
Clearwater Tech   © 2011 PRIVACY POLICY TERMS OF USE LEGAL INFO USAGE POLICY