Entrelec Current Sensors
When The Monitored Current
is 5 ampere-turns, the panel mount LPM indicator will glow. The LCS10T12 is designed to maximize the light output of the panel
mount indicator. It can be used to monitor current flow of less than 5 A by passing the monitored conductor 2 or more times
through the sensor. The LCS10T12 must be connected to the LPM12 or LPMG12 before current flows to prevent damage or a shock
hazard.
|
NK Fault Sensors
The AGL Series,
new from NK Technologies, is a large aperture ground fault sensor that offers one of the largest aperture diameters in the
industry while maintaining a compact overall profile. Intended for sensing earth leakage in applications up to 600A, the AGL
Series offers a choice of N.O. or N.C. latching relays or an SPDT Form C relay with auto-reset.
|
|
|
|
 |
(800) 894-0412 (208) 368-0415 (Fax) info@clrwtr.com |
 Model LSRX |
SymCom Model LSRX is an AC current sensor designed to energize the output contact whenever 4.5
Amps or greater is present. The LSRX is used commonly as an AC current proof relay to indicate if a motor is operating. It can
also be used to interlock fans, compressors, and motors; to indicate equipment status such as feed rates, tool wear, loss of
prime on pumps, mixer viscosity, and all types of current sensing conditions; or to stage pump motors, chillers, or other
machinery.
This device combines a current transformer (CT), transducer, and high current output relay together to
switch alarm circuits, contactors, and most resistive or inductive loads. The LSRX can perform the function of an auxiliary
contact, yet has the advantages of universal application and isolation.
|
|
If you are looking for SymCom Load Sensors, please call us on
(800) 894 - 0412 or email us at
info@clrwtr.com
we will do our best to help you find the SymCom MotorSaver AC Current Sensor that you are looking for at the most competitive
prices possible. If you are searching for SymCom Microcontroller Based Load Sensors technical information (data-sheets)
please use the datasheets or product selection guide page links.
|
 Model LSR-0 |
SymCom Model LSR-0 is a preset load sensor designed to switch whenever 15A is present and
drop out at 2.5A. The LSR-0 is used commonly as lockout protection on oil pressure controls due to compressor overload
shutdown. It can also be used to interlock fans, compressors, and motors; to indicate equipment status such as feed rates, tool
wear, loss of prime on pumps, mixer viscosity, and all types of over and under load conditions, or to stage pump motors,
chillers, and other machinery.
|
 Model LSR-24, LSR-115 & LSR-230 |
Model LSR-24, LSR-115, & LSR-230 Load Sensors use current levels to determine feed rates, tool wear,
loss of prime on pumps, mixer viscosity, and all types of over and under load conditions. They may also be used to stage pump
motors, chillers, and other machinery. These devices combine a current transformer (CT) with Form C (SPDT) relay contacts to
switch alarm circuits, contactors, or any resistive or inductive load. One simple screwdriver adjustment will calibrate the
sensor for all single phase or three phase applications up to 100 Hp. The LSR-24 uses 24 VAC control voltage; the LSR-115
uses 115 VAC control voltage; and the LSR-230 uses 230 VAC control voltage.
|
 Model LSRU |
The Model LSRU load sensors use current levels to monitor all types of over and underload conditions such
as feed rates, tool wear, pump loads, mixer viscosity and others. They may be used to stage pumps, chillers and other
machinery. Two user adjustments are provided with your choice of overcurrent, undercurrent, trip delay, restart delay and
extended restart delay options. Three current ranges, 0-10A, 5-25A and 25-100A, are available.
|
 Model LSRU-AL |
SymCom Model LSRU-AL is a dual trip point load monitor. It can be used to determine feed rates, tool wear,
loss of prime on pumps, mixer viscosity, and all types of over and under load conditions. These devices combine a current
transformer (CT) with form C relay contacts to switch alarm circuits, or any resistive or inductive load. When the current
draw is within the limits defined by the two user adjustments, the relay is energized. When the current falls outside of this
range for one second, the relay will de-energize.
|
 Model LSRU-FC |
SymCom Model LSRU-FC is a load monitor intended to control feed mechanisms in a variety of applications.
Sawmills, elevators, gravel quarries and other industrial sites use conveyers and augers to feed wood, grain, rock and other
materials into cutting, chipping, grinding and material handling equipment. The Model LSRU-FC can also be used to control the
cooling element in frozen drink machines, railroad car shakers, which are used to unload some railcars, and other unique
applications. Model LSRU-FC optimizes these systems by stopping the feeder when the grinder, chipper, saw or auger nears
overload. When the load is reduced to a preset level, the feeder is restarted.
|
 Model LS-524 |
SymCom Model LS-524 Load Sensor uses current levels to accurately indicate load loss on fans, pumps,
conveyors, or any electrical circuit for building automation systems. Since current typically drops 50% to 70% on many load
loss situations, the Model LS-524 device can easily be set to indicate this condition. One simple screwdriver adjustment will
calibrate this model for all single phase or three phase applications up to 135 Amps.
|
|
Our industrial factory automation supplies distributors warehouse in Boise, Idaho USA stocks some SymCom
products enabling us to further assist you in finding the correct SymCom LSRU-24-AL-2 alarm logic in the USA, Canada and
Mexico. Whether we have MotorSaver LSRU-115-FC-1.5 feed control in stock in Boise, Idaho USA or need to ship direct from
SymCom to any USA cities; Clearwater Tech can get SymCom LSRU-115-OR-1.5 overcurrent restart delay to you fast and save
you some money! It will be very helpful if you have the SymCom Load Sensor part numbers ready, then our sales representatives
can provide you with a pricing and availability quote for SymCom LSRU-115-OT-3 overcurrent trip delay that you are looking
for in seconds. If you do not have the part numbers for SymCom LSRU-115-UE-2 undercurrent extended restart delay, our
application engineers will be able to help you figure out the part numbers and get the price quote to you as soon as
possible.
|
|
|
|
 |
|