SymCom
Home > Products >
SymCom > Motor Protection
|
 |
(800) 894-0412 (208) 368-0415 (Fax) info@clrwtr.com |
 SymCom MotorSaver Model 777 |
SymCom 777 Overload Relay can be
used on any 190-480VAC, 3-phase system drawing 2-800A and will protect motors against the following damaging conditions:
overload, underload, jams, undervoltage, overvoltage, single-phasing, voltage and current unbalance, ground fault (Class II),
rapid cycling and phase reversal.
|
|
If you are looking for SymCom Motor Protection, please call us on
(800) 894 - 0412 or email us at
info@clrwtr.com we
will do our best to help you find the SymCom MotorSaver that you are looking for at the lowest prices possible. If you are
searching for SymCom PumpSaver technical information (data-sheets) please use the
SymCom Datasheets OR
Product Selection Guide page links.
|
 SymCom PumpSaver 777-KW/HP |
SymCom 777-KW/HP products should be used with all
Fractional Horsepower Motors when underload protection is needed, and with most motors
under 3 hp. Also use KW/HP products when the motor is derated (Ex: Coal bed methane well with a 7.5hp submersible pump on a
10hp motor.) Other typical applications are mixer motors up to 50hp and beyond that run at less than 1800 rpm, magdrive pumps
and can pumps. If in doubt, underpower can be used anytime in place of undercurrent protection. Settings can be either
horsepower or kilowatts.
|
 SymCom MotorSaver 777-MV |
SymCom 777-MV is specifically designed for medium voltage applications where both PTs
(potential transformers) and CTs (Current Transformers), are used. It has a
120-240V nominal voltage range, and built-in multipliers for 25:5, 50:5, 100:5, CTs. The voltage unbalance, single-phase and
reverse-phase protection can be disabled to accommodate applications where only one PT is used.
|
 SymCom MotorSaver 777-HVR |
SymCom 777-HVR products are used in 480V applications when a CPT (Control Power Transformer)
is not used. The HVR products have a 380-480V range and a relay rated at 480VA @ 600VAC pilot duty, and are commonly used in
pumping applications to save the cost and extra wiring associated with a CPT.
|
 SymCom MotorSaver 777-FT |
SymCom 777-FT is intended for applications where a fast linear trip is required. It has an
overcurrent trip delay that can be set to less than 500 ms, to be used in applications where very short trip delays are needed
to prevent chain drives and other drive linkages from breaking in an overload or jam situation. Often times it is referred to
as a shock relay. Some applications include sewage clarifiers, mixers, augers and conveyors. The trip delay can be set to as
much as 70 seconds, so it can also be used when a slower than normal trip is desired. A slower trip may be desired in certain
applications such as motor test panels in a rewind shop.
|
 SymCom MotorSaver Model 777-PH |
SymCom 777-PH Add-A-Phase is specially designed for use with static and rotary single to
3-Phase Converters. Voltage unbalance protection is disabled and the high and low voltage
trip features apply only to one phase L1-L2. This allows SymCom 777 to ignore the severely unbalanced voltages that are
inherent to unloaded phase converters.
|
 SymCom MotorSaver 777-TS |
SymCom 777-TS is specifically designed for use with a Subtrol-equipped Franklin
submersible motor to detect high motor temperatures.
|
 SymCom PumpSaver 777-AccuPower |
SymCom 777-AccuPower allows motor hp rating, full load amps, efficiency, and power factor
to be entered and will accurately calculate and display motor output power. The 777-AccuPower can be used with SymCom's 4-20mA
output module to give an analog signal proportional to this output power.
|
|
Our SymCom distributors warehouse in Boise, Idaho USA stocks some SymCom Model 777 products (SymCom Model
777 MotorSaver Overload Relays PumpSaver Motor Protection AccuPower Power Monitors Distributors) enabling us to
further assist you in finding the correct SymCom Model 777 Overload Relays in the USA (Alabama Alaska Arizona Arkansas
California Colorado Connecticut Delaware Florida Georgia Hawaii Idaho Illinois Indiana Iowa Kansas Kentucky Louisiana Maine
Maryland Massachusetts Michigan Minnesota Mississippi Missouri Montana Nebraska Nevada New Hampshire New Jersey New Mexico New
York North Carolina North Dakota Ohio Oklahoma Oregon Pennsylvania Rhode Island South Carolina South Dakota Tennessee Texas
Utah Vermont Virginia Washington Washington D.C. West Virginia Wisconsin Wyoming), Canada and Mexico.
Whether we have SymCom MotorSaver 777 in stock in Boise, Idaho USA or need to ship direct from SymCom to
any USA cities (New York Los Angeles Chicago Houston Philadelphia Phoenix San Diego Dallas San Antonio Detroit San Jose
Indianapolis San Francisco Columbus Austin Baltimore Milwaukee Boston Washington El Paso Seattle Denver Charlotte Fort Worth
Portland Oklahoma City Tucson New Orleans Las Vegas Cleaveland Long Beach Alburquerque Kansas City Fresno Virginia Beach Atlanta
Sacramento Oakland Mesa Tulsa Omaha Minneapolis Honolulu Colorado Springs St. Louis Whichita Santa Ana Pittsburgh Arlington
Cincinnati Anaheim Toledo Buffalo St. Paul Corpus Christi Aurora Raleigh Newark Lexington Fayette Anchorage Louisville Riverside
Bakersfield Stockton Birmingham Jersey City Norfolk Baton Rouge Hialeah Lincoln Greensboro Plano Rochester Glendale Akron Garland
Madison Fort Wayne Fremont Scottsdale Montgomery Shreveport Lubbock Chesapeake Mobile Des Moines Grand Rapids Richmand Yonkers
Spokane Augusta Rhichmand Glendale Tacoma Irving Huntington Beach Arlington Modesto Durham Boise Winston Salem);
www.clrwtr.com can get SymCom PumpSaver 777 to you fast and save you some
money!
It will be very helpful if you have the SymCom Model 777 part numbers ready, then our sales
representatives can provide you with a pricing and availability quote for SymCom MotorSaver Overload Relays that you are
looking for in seconds. If you do not have the part numbers for SymCom PumpSaver Power Monitors, our application engineers
will be able to help you figure out the part numbers and get the price quote to you as soon as possible.
|
|
|
|
 |
|
| Part Number: |
|
|
Can't find a part number?
E-mail Us! |
|
|