(800) 894-0412 (208) 368-0415 (Fax) info@clrwtr.com |
 Model PC-102CICI-DL |
SymCom's PC-102CICI-DL is a Dual seal-Leak detector.
The inputs are used to sense seal failures on pumps. When water is detected, the associated output relay
is energized.
The input logic may be selected to be direct or inverted using DIP switches on the side of the device.
It has two isolated form-C output relays and two red LEDs which illuminate when the associated output
relay is energized.
|
|
If you are looking for SymCom Pump Controllers, please call us on
(800) 894 - 0412 or email us at
info@clrwtr.com
we will do our best to help you find the SymCom Seal Leak Detectors that you are looking for at the most competitive
prices possible. If you are searching for SymCom Liquid Level Controls technical information (data-sheets) please use the
datasheets or product selection guide page links.
|
 Model PC-102CICI-LT |
SymCom's PC-102CICI-LT is a seal-Leak and over-Temperature detector.
The seal-leak input is used to sense seal failures on submersible pumps while the temperature input is
used to detect motor overheating. Both can be configured to suit the probes of your choice.
It has two form-C isolated output relays and two LEDs, which illuminate when each associated output relay
is energized.
|
 Model PC-105 |
SymCom's PumpControl Model PC-105 is a five-channel pump controller designed to handle multiple pump
applications. Alternatively, it can operate as a 5-channel switch.
The PC-105s control functions support all of the popular industry-standard multi-pump configurations.
Using the built-in DIP switches, individual pumps can be disabled when taken out of service for repair or maintenance.
|
 Liquid Level Control Relays |
The PC-xxx-LLC-CZ & PC-xxx-LLC-GM are liquid level control relays used to control conductive liquid
pumping operations in a pump-up or pump-down application. The unit comes in two different voltage ranges. The model
PC-100-LLC-CZ & PC-100-LLC-GM are for 95-120VAC applications and the model PC-200-LLC-CZ & PC-200-LLC-GM are for
190-240VAC applications.
The unit has an adjustable sensitivity knob (4.7-100K ohms) that is set according to the resistance level
at which you want the probes (sold separately) to sense the conductive liquid. The unit has a built-in debounce time delay
that prevents the relay from energizing if the probe resistance momentarily goes above or below the sensitivity setpoint (due to
liquid splashing in the tank).
|
 Model 201-100-SLD |
The MotorSaver Model 201-100-SLD plug-in mount seal leak detector is used to sense seal failures on
submersible pumps. The 201-100-SLD plugs into an OT08-PC or RB08-PC octal socket (sold separately).
When the unit is powered and the resistance from the probe is greater than the sensitivity control
level, the internal relay contacts change state. As water leaks into the motor seal, the resistance measured by the
probe decreases. When the resistance drops below the sensitivity control level, the unit will trip and the relay
contacts will change back to their original state.
|
 Model 460-15-100-SLD |
The MotorSaver Model 460-15-100-SLD is a DIN rail or surface mountable seal leak detector used to sense
seal failures on submersible pumps.
When the unit is powered and the resistance from the probe is greater than the sensitivity control level,
the internal relay contacts change state. As water leaks into the motor seal, the resistance measured by the probe
decreases.
When the resistance drops below the sensitivity control level, the unit will trip and the relay contacts
will change back to their original state.
|
 Model 460-15-100-LLS |
The PumpSaver Model 460-15-100-LLS is a liquid level sensor to detect the presence of conductive liquids.
The unit has an adjustable debounce timer (2-60 seconds) to help prevent nuisance relay actuations due to waves or liquid
splashing into the tank.
When the probe is submersed, the PumpSaver's output contacts will change state as soon as the debounce
time expires.
Relay logic can be inverted so the PumpSaver's output contacts change state when the probe is no longer
submersed.
|
 Model ACBC-120 |
SymCom's Model ACBC-120 is a dual purpose alarm controller/battery charging unit. When there is a loss of
120VAC power, the ACBC-120's primary function as an alarm controller activates. When this power loss occurs, input power is
switched to a 12VDC, lead-acid, rechargeable backup battery and a 12VDC alarm consisting of a strobe light and/or a horn is
activated. The horn follows a 2 second on/2 second off pattern with a "horn silence" option to turn the sound off.
The device has the ability to signal low battery voltage if the voltage drops below 10.5VDC. The device
can also detect if no battery is present or if the battery is connected backwards. In either of these cases, the ACBC-120
will signal a battery error and will not attempt to charge.
|
 Model ALT-100-1-SW & ALT-200-1-SW |
Alternating relays are used to alternate between two loads and are commonly used in duplex pump-up and
pump-down applications to balance the runtime of both pumps.
The ALT-xxx-1-SW alternating relays are 11-pin octal base plug-ins, available in two different
single-phase voltage ranges. The ALT-100-1-SW is used for 95-120VAC applications and the ALT-200-1-SW is used for 190-240VAC
applications. Both models are designed for a single float input and feature two isolated Form C relays (DPDT) outputs with
two LEDs to indicate the energized load.
|
 Model ALT-100-3-SW & ALT-200-3-SW |
The ALT-xxx-3-SW alternating relays are 8-pin octal base plug-ins, available in two different
single-phase voltage ranges. The ALT-100-3-SW is used for 95-120VAC applications and the ALT-200-3-SW is used for
190-240VAC applications. Both models are designed for three float inputs (lead, lag and stop floats). The lead and lag
floats actuate latching relays that release when the stop float actuates. The units feature two LEDs to indicate the
energized load(s).
The ALT relays have a built-in debounce time delay that prevents the relay from changing state if the
float momentarily bounces, and they have a built-in switch to manually force a specific load (pump) to operate each time
the input float closes.
|
|
Our SymCom distributors warehouse in Boise, Idaho USA stocks some PumpSaver products enabling us to
further assist you in finding the correct PC-200-LLC-CZ 2 input liquid level controls in the USA. Whether we have SymCom
PC-100-LLC-GM in stock in Boise, Idaho USA or need to ship direct from SymCom to any USA cities; Clearwater Tech can
get PC-200-LLC-GM liquid level control relays to you fast and save you some money! It will be very helpful if you have the
SymCom 201-100-SLD part numbers ready, then our sales representatives can provide you with a pricing and availability quote
for 460-15-100-SLD seal leak detector that you are looking for in seconds. If you do not have the part numbers for
460-15-100-LLS liquid level sensor, our application engineers will be able to help you figure out the part numbers