The use of flow restrictors, unusually high head pressures, or low water conditions at the time of calibration may interfere with the detection of dead-head and dry-well conditions.

SymCom Model 111-Insider-P Single-Phase PumpSaver Plus Distributors

111-Insider-P

The Model 111-Insider-P single-phase PumpSaver Plus fits inside 1/3 and 1/2 hp 115V control boxes. The PumpSaver Plus Model 111-Insider-P is designed to protect single-phase pumps from dry well, dead head, jammed impeller and over and undervoltage conditions.

A calibration adjustment allows the Insider-P to be calibrated to your specific pumping applications, thereby reducing the possibility of false or nuisance tripping. A unique microcontroller based voltage and current sensing circuit constantly monitors the incoming power for fluctuations, overcurrent and undercurrent. When an abnormality, such as loss of suction is detected, the PumpSaver Plus deactivates its output relay and directly disconnects the pump motor. The PumpSaver Plus then begins its user-selectable restart delay (dry-well recovery) timer. When the timer counts down to zero or power is removed and reapplied, the PumpSaver Plus reactivates its output relay, allowing the pump to turn back on.

If you are looking for SymCom PumpSavers, please call us on (800) 894 - 0412 or email us at info@clrwtr.com we will do our best to help you find the SymCom 3-Phase INSIDER PumpSaver Plus that you are looking for at the most competitive prices possible. If you are searching for SymCom 1-Phase PumpSaver technical information (data-sheets) please use the datasheets or product selection guide page links.

SymCom Model 231-INSIDER-P Single-Phase PumpSaver Plus Distributors

231-INSIDER-P

SymCom's Model 231-Insider-P single-phase PumpSaver Plus fits inside 1/3, 1/2, 3/4, and 1hp 230V control boxes and is designed to protect single-phase pumps from dry-well, dead-head, jammed impeller, rapid-cycle, overvoltage, and undervoltage conditions.

A calibration adjustment allows the Insider-P to be calibrated to specific pumping applications, thereby reducing the possibility of false or nuisance tripping. A unique microcontroller-based voltage and current-sensing algorithm constantly monitors the incoming power for fluctuations.

When an abnormality, such as a loss of load is detected, the PumpSaver Plus deactivates its output relay directly disconnecting the pump motor. The PumpSaver Plus then begins its user-selectable restart delay (dry-well recovery) timer.

When the timer counts down to zero or power is removed and reapplied, the PumpSaver Plus reactivates its output relay, allowing the pump to turn back on.

SymCom Model 112-Insider & 232-Insider Single-Phase PumpSavers Distributors

232-Insider

The Model 232-Insider single-phase PumpSaver fits inside 1/3, 1/2, 3/4, and 1hp, 230V Grundfos control boxes.

The Model 112-Insider single-phase PumpSaver fits inside 1/3 and 1/2hp, 115V Grundfos control boxes.

The PumpSaver Model 112/232-Insider is a current monitor designed to protect single-phase pumps from dry-well, dead-head, jammed impeller, overvoltage and undervoltage conditions.

Typical applications include residential water wells, commercial water wells, irrigation wells, and golf course systems.

SymCom Model 111P Single-Phase PumpSaver Plus Distributors

111P

The Model 111P single-phase PumpSaver Plus is a pump monitor designed to protect single-phase pumps from dry-well, dead-head, jammed impeller, rapid cycle and overvoltage and undervoltage conditions.

The PumpSaver Plus Model 111P protects 115 volt, 2 or 3 wire, 1/3 to 1 hp pumps.

A calibration adjustment allows the Model 111P to be calibrated to your specific pumping applications, thereby reducing the possibility of false or nuisance tripping.

SymCom Model 233P Single-Phase PumpSaver Plus Distributors

233-P

SymCom Model 233-P single-phase PumpSaver Plus is a pump monitor designed to protect single-phase pumps from dry-well, dead-head, jammed impeller, rapid cycle and overvoltage and undervoltage conditions.

The PumpSaver Plus Model 233-P protects 230 volt, 2 or 3 wire, 1/3 to 3 hp pumps.

A calibration adjustment allows the Model 233P to be calibrated to your specific pumping applications, thereby reducing the possibility of false or nuisance tripping.

SymCom Model 234-P Single-Phase PumpSaver-Grundfos Control Boxes Distributor

234-P

SymCom PumpSaver Model 234-P protects single-phase pumps from dry-well, dead-head, rapid-cycle, jammed-impeller, and over/undervoltage conditions.

Typical applications include residential waterwells, commercial waterwells, irrigation wells, and golf course and other sprinkler systems.

The PumpSaver Model 234-P is designed to be mounted inside a Grundfos control box to protect 1/3 - 3hp, 2- or 3-wire, 230V pumps.

An infrared LED communicates directly with a hand-held diagnostic tool called the Informer (sold separately).

SymCom Model 235P Single-Phase PumpSaver Plus Distributors

235P

The Model 235P PumpSaver Plus is designed to protect single-phase pumps from dry-well, dead-head, jammed impeller and overvoltage and undervoltage conditions.

The PumpSaver Plus Model 235P protects 5-15 hp, 230V pumps.

A calibration adjustment allows the Model 235P to be calibrated to your specific pumping applications, thereby reducing the possibility of false or nuisance tripping.

SymCom Pump Saver Model 77C-KW/HP 77C-LR-KW/HP Electronic Overload Relays Distributor

77C-KW/HP

SymCom has important advantages over current monitors in many protection applications.

Any motor load that has a small or very non-linear change in current vs. load requires the use of a power monitor for underload, dry run and dead-head protection.

The change in power vs. load is more linear for most motor loads and is greater in magnitude than the change in current in all motor loads.

This is because power measurements take into account both power factor (pf) and current.

SymCom Model 777-KW/HP-P2 Series Power Monitors Distributors

777-KW/HP-P2

The Model 777-KW/HP-P2 Series is a family of fully programmable electronic power monitors. They are designed to monitor and protect any 3-phase 200-480VAC (500-600VAC for 777-575-KW/HP-P2) motor drawing 2-800 full load amps (external CTs are required above 90 amps).

They provide unsurpassed protection from faulty voltage, underload and overload conditions. The 777-KW/HP-P2 can be used in a variety of 3-phase applications and features a low power trip point (adjustable on the unit) that is desirable any time the current vs. load characteristic is non-linear or has little change.

SymCom Informer Diagnostic Tool for Single-Phase PumpSaver & PumpSaver Plus Distributors

Informer

The Informer is a handheld diagnostic tool designed for use with single-phase PumpSaver and PumpSaver Plus models equipped with infrared LED transmitters.

The Informer uses an infrared receiver to access information sent from the PumpSaver or PumpSaver Plus, which can be helpful for troubleshooting the system.

Each SymCom single-phase PumpSaver and PumpSaver Plus model, equipped with an infrared LED, transmits valuable information from the device.

To retrieve this information, the Informer's receiver must be directed toward the PumpSaver's LED transmitter and be within 10 feet of the unit (12" if using IR Kit).

The green COMM STATUS light indicates when the Informer is receiving data from the PumpSaver or PumpSaver Plus.

SymCom Model 777-HVR-KW/HP-P2 Power Monitors Distributor

777-HVR-KW/HP-P2

The 777-HVR-KW/HP-P2 Series units can be used as a stand-alone product or the RS-485 communications port can be used to form a network to communicate with a PC, PLC or SCADA system.

The 777-HVR-KW/HP-P2 units can be used with CIO modules produced by SymCom for several types of communication protocols. Up to 99 model 777-HVR-KW/HP-P2 units can be networked together and monitored and controlled by SymCom's Solutions software. The units can also be connected to SymCom's remote monitors for a simple, cost-effective way to meet new requirements for arc-flash safety.

SymCom Model 777-LR-KW/HP-P2 Power Monitors Distributors

777-LR-KW/HP-P2

The 777-LR-KW/HP-P2 Series units incorporate a 3-digit LED display that is used for programming, providing real-time operational information, and displaying diagnostic codes to aid in troubleshooting a fault condition.

The unit's many features include enhanced trip classes beyond the NEMA standard trip classes. The settable trip class range is 2-60, with or without jam protection, and a secondary linear trip delay can be set with a range of 0-60 seconds. If both trip class and linear trip delay are set, the 777-LR-KW/HP-P2 will follow the faster trip time. Another feature is the automatic dry-well recovery timer that allows the unit to automatically select a restart delay based on the last cycle's run time.

SymCom PumpSaver 777-AccuPower Overload Relays Power Monitors Distributor

777-AccuPower

SymCom 777-AccuPower allows motor hp rating, full load amps, efficiency, and power factor to be entered and will accurately calculate and display motor output power.

The 777-AccuPower can be used with SymCom's 4-20mA output module to give an analog signal proportional to this output power.

Our industrial factory automation supplies distributors warehouse in Boise, Idaho USA stocks some SymCom Pump Saver products enabling us to further assist you in finding the correct 3-Phase PumpSaver models 77C-KW/HP & 77C-LR-KW/HP in the USA, Canada and Mexico. Whether we have 1-Phase PumpSaver Plus in stock in Boise, Idaho USA or need to ship direct from SymCom to any USA cities; Clearwater Tech can get model 777-KW/HP-P2 to you fast and save you some money! It will be very helpful if you have the SymCom 777-HVR-KW/HP-P2 part numbers ready, then our sales representatives can provide you with a pricing and availability quote for 777-HVR-KW/HP-P2 Pump Savers that you are looking for in seconds. If you do not have the part numbers for SymCom 1-Phase PumpSaver, our application engineers will be able to help you figure out the part numbers and get the price quote to you as soon as possible.

Stock Check

Part No:
OR
Manufacturer:

Search Tips
Can't find a part number?
E-mail Us!

NK Switches

The AS1-CC Series current sensing switch is a powerfully simple solution to complicated control requirements. When a user needs to know that a circuit is energized but they don't want to cut into the insulation or add burden to the monitored circuit, a current operated switch is the best solution. And when the primary circuit draw is less than 50 amps, a small, well-insulated device such as

Hammond Racks

RACK BASICS products are available through all Hammond Mfg Distributors in Canada. The current RACK BASICS product line includes wallmounts (SWCC, WMC and FWB) and server cabinets (DC200). Our latest introduction to the RACK BASICS brand is the RB-2P77 economy 2-Post Open Frame Rack. "Our new RB-2P77 economy 2-Post rack is directly comparable to the heavy duty offering of our competition," said Hammond.