June 16, 2010
Hitachi Drives
The L100 Inverter Drive
features state-of-the-art circuitry and components to provide high performance. The housing footprint is exceptionally small,
given the size of the corresponding motor. The Hitachi L100 product line includes more than a dozen inverter models to cover
motor sizes from 1/4 horsepower to 10 horsepower, in either 230 VAC or 460 VAC power input versions.
|
ABB Drives
The Wall-Mounted ACS800-11
regenerative drive is equipped with active supply unit. It offers a full performance regenerative drive in a single compact
package. All important features and options including an LCL line filter and EMC filter are built inside the drive. The power
ratings start from 5.5 kW and go up to 110 kW. It is available with IP21 protection degree.
|
|
|
|
 |
(800) 894-0412 (208) 368-0415 (Fax) info@clrwtr.com |
 Model 111-Insider-P |
The Model 111-Insider-P single-phase PumpSaver Plus fits inside 1/3 and 1/2 hp 115V control boxes. The
PumpSaver Plus Model 111-Insider-P is designed to protect single-phase pumps from dry well, dead head, jammed impeller and
over and undervoltage conditions.
A calibration adjustment allows the Insider-P to be calibrated to your specific pumping applications,
thereby reducing the possibility of false or nuisance tripping.
The 111-Insider-P communicates with a hand-held diagnostics tool called the Informer (sold separately).
The Informer displays 15 parameters including calibration points, trip points, running points, and last faults. An IR Kit-12
(12" fiber optic kit) is included with each 111-Insider-P, allowing the Informer to access these parameters even when the
111-Insider-P is enclosed in a control box. This is valuable for troubleshooting the pump while it is running.
|
|
If you are looking for SymCom PumpSavers, please call us on
(800) 894 - 0412 or email us at
info@clrwtr.com
we will do our best to help you find the SymCom 3-Phase INSIDER PumpSaver Plus that you are looking for at the most competitive
prices possible. If you are searching for SymCom 1-Phase PumpSaver technical information (data-sheets) please use the
datasheets or product selection guide page links.
|
 Model 231-Insider-P |
SymCom's Model 231-INSIDER-P single-phase PumpSaver Plus fits inside 1/3, 1/2, 3/4, and 1hp
230V control boxes and is designed to protect single-phase pumps from dry-well, dead-head, jammed impeller, rapid-cycle,
overvoltage, and undervoltage conditions.
A unique microcontroller-based voltage and current-sensing algorithm constantly monitors the incoming
power for fluctuations. When an abnormality, such as a loss of load is detected, the PumpSaver Plus deactivates its output
relay directly disconnecting the pump motor. The PumpSaver Plus then begins its user-selectable restart delay (dry-well
recovery) timer. When the timer counts down to zero or power is removed and reapplied, the PumpSaver Plus reactivates its
output relay, allowing the pump to turn back on.
|
 Model 112-Insider & 232-Insider |
The Model 232-Insider single-phase PumpSaver fits inside 1/3, 1/2, 3/4, and 1hp, 230V
Grundfos control boxes. The Model 112-Insider single-phase PumpSaver fits inside 1/3 and 1/2hp, 115V Grundfos control boxes. The
PumpSaver Model 112/232-Insider is a current monitor designed to protect single-phase pumps from dry-well, dead-head, jammed
impeller, overvoltage and undervoltage conditions. Typical applications include residential water wells, commercial water wells,
irrigation wells, and golf course systems.
- Fits inside Grundfos control boxes
- State-of-the-art pump protection
- Fuzzy logic software
- Infrared LED communication to Symcom's Informer
|
 Model 111P |
The Model 111P single-phase PumpSaver Plus is a pump monitor designed to protect single-phase pumps
from dry-well, dead-head, jammed impeller, rapid cycle and overvoltage and undervoltage conditions. The PumpSaver Plus
Model 111P protects 115 volt, 2 or 3 wire, 1/3 to 1 hp pumps. An infrared LED communicates directly with a hand-held
diagnostic tool called the Informer (sold separately).
|
 Model 233-P |
SymCom Model 233-P single-phase PumpSaver Plus is a pump monitor designed to protect
single-phase pumps from dry-well, dead-head, jammed impeller, rapid cycle and overvoltage and undervoltage conditions. The
PumpSaver Plus Model 233-P protects 230 volt, 2 or 3 wire, 1/3 to 3 hp pumps.
- Ideal for submersible pumps
- State-of-the-art pump protection
- UL Listed
|
 Model 234-P |
SymCom PumpSaver Model 234-P protects single-phase pumps from dry-well, dead-head, rapid-cycle,
jammed-impeller, and over/undervoltage conditions. Typical applications include residential waterwells, commercial
waterwells, irrigation wells, and golf course and other sprinkler systems.
The PumpSaver Model 234-P is designed to be mounted inside a Grundfos control box to protect 1/3 - 3hp,
2- or 3-wire, 230V pumps. An infrared LED communicates directly with a hand-held diagnostic tool called the Informer (sold
separately).
|
 Model 235 |
The Model 235P PumpSaver Plus is designed to protect single-phase pumps from dry-well, dead-head, jammed
impeller and overvoltage and undervoltage conditions. The PumpSaver Plus Model 235P protects 5-15 hp, 230V pumps. The Model
235P communicates with a hand-held diagnostics tool called the Informer (sold separately). The Informer displays 15
parameters including calibration points, trip points, running points, and last faults. An external current transformer is
required for operation.
|
 Model 77C-KW/HP & 77C-LR-KW/HP |
SymCom Model 77C-KW/HP has important advantages over
current monitors in many protection applications. Any motor load that has a small or very non-linear change in current vs.
load requires the use of a power monitor for underload, dry run and dead-head protection. The change in power vs. load is
more linear for most motor loads and is greater in magnitude than the change in current in all motor loads. This is because
power measurements take into account both power factor (pf) and current.
|
 Model 777-KW/HP-P2 |
The Model 777-KW/HP-P2 Series is a family of fully programmable electronic power monitors. They are
designed to monitor and protect any 3-phase 200-480VAC (500-600VAC for 777-575-KW/HP-P2) motor drawing 2-800 full load amps
(external CTs are required above 90 amps). They provide unsurpassed protection from faulty voltage, underload and overload
conditions. The 777-KW/HP-P2 can be used in a variety of 3-phase applications and features a low power trip point
(adjustable on the unit) that is desirable any time the current vs. load characteristic is non-linear or has little
change.
|
 Model 777-HVR-KW/HP-P2 |
The 777-HVR-KW/HP-P2 Series units can be used as a stand-alone product or the RS-485 communications port
can be used to form a network to communicate with a PC, PLC or SCADA system. The 777-HVR-KW/HP-P2 units can be used with CIO
modules produced by SymCom for several types of communication protocols. Up to 99 model 777-HVR-KW/HP-P2 units can be
networked together and monitored and controlled by SymCom's Solutions software. The units can also be connected to SymCom's
remote monitors for a simple, cost-effective way to meet new requirements for arc-flash safety.
|
 Model 777-LR-KW/HP-P2 |
The 777-LR-KW/HP-P2 Series units incorporate a 3-digit LED display that is used for programming, providing
real-time operational information, and displaying diagnostic codes to aid in troubleshooting a fault condition. The unit's
many features include enhanced trip classes beyond the NEMA standard trip classes. The settable trip class range is 2-60,
with or without jam protection, and a secondary linear trip delay can be set with a range of 0-60 seconds. If both trip
class and linear trip delay are set, the 777-LR-KW/HP-P2 will follow the faster trip time. Another feature is the automatic
dry-well recovery timer that allows the unit to automatically select a restart delay based on the last cycle's run time.
|
 Model 777-AccuPower |
SymCom 777-AccuPower allows motor hp rating, full load amps, efficiency, and power factor
to be entered and will accurately calculate and display motor output power. The 777-AccuPower can be used with SymCom's 4-20mA
output module to give an analog signal proportional to this output power.
|
 Model 236-P |
SymCom PumpSaver Model 236-P protects single-phase pumps from dry-well, dead-head, rapid-cycle,
jammed-impeller, and over/undervoltage conditions. Typical applications include residential waterwells, commercial
waterwells, irrigation wells, and golf course and other sprinkler systems.
The PumpSaver Model 236-P is designed to be mounted inside a Grundfos control box to protect 5 or 7.5hp,
230V pumps. An infrared LED communicates directly with a hand-held diagnostic tool called the Informer (sold separately).
|
|
Our industrial factory automation supplies distributors warehouse in Boise, Idaho USA stocks some SymCom
Pump Saver products enabling us to further assist you in finding the correct 3-Phase PumpSaver models 77C-KW/HP &
77C-LR-KW/HP in the USA, Canada and Mexico. Whether we have 1-Phase PumpSaver Plus in stock in Boise, Idaho USA or need to
ship direct from SymCom to any USA cities; Clearwater Tech can get model 777-KW/HP-P2 to you fast and save you some money! It
will be very helpful if you have the SymCom 777-HVR-KW/HP-P2 part numbers ready, then our sales representatives can provide
you with a pricing and availability quote for 777-HVR-KW/HP-P2 Pump Savers that you are looking for in seconds. If you do not
have the part numbers for SymCom 1-Phase PumpSaver, our application engineers will be able to help you figure out the part
numbers and get the price quote to you as soon as possible.
|
|
|
|
 |
|
| Part Number: |
|
|
Can't find a part number?
E-mail Us! |
|
|