(800) 894-0412 (208) 368-0415 (Fax) info@clrwtr.com |
 Limit Value Monitor |
The limit value monitors IM43-13-SR and IM43-14-SRi are single-channel devices and alternately monitor
measuring current of 0/4-20 mA or measuring voltages of 0/2-10 V. The three limit values are set via the front panel teach
button. In addition, a voltage of approx. 18 V (at 35 mA max.) is provided, which can be used to power transmitters or sensors.
The output mode is jumper programmable at terminals 5-8.
- 1-channel monitor with removable terminal blocks
- Input either via current input 0/4-20 mA or voltage input 0/2-10 V
- Supply of a 2-wire or 3-wire transmitter/sensor
- Limit value adjustment via teach button
- 3 relay outputs, each with one normally open output
- Current output of 0/4-20 mA. (IM43-14-SRi only)
- Universal operating voltage (20-250 VUC)
|
|
If you are looking for TURCK Logic Controllers, please call us on
(800) 894 - 0412 or email us at
info@clrwtr.com
we will do our best to help you find the TURCK Set-Point Controllers that you are looking for at competitive prices. If you
are searching for TURCK Controller technical information (data-sheets) please use the datasheets or product selection guide
page links.
|
 Single Channel Temperature Converter |
This single channel device is designed to provide an analog 4/20 mA signal to a control system that is
converted from an RTD, T/C or mV signal in a hazardous area. This device is software configurable using the
PACTware Software tool and a configuration cable that allows configuration to be
achieved through your laptop or PC. This device has the added function of a relay output that can be used for under/over range
conditions or to monitor a limit value.
- 1 channel temperature input
- Accepts 2, 3 or 4-wire RTD's, T/C's or mV
- Software configurable by user via PC using PACTware with software tool "Device Type Manager" (DTM)
- Temperature range adjustable
- Configurable limit value relay output
- Over/under current indication of 0 or 22 mA
- Internal or external CJC configurable
|
 Set-Point & Logic Controller |
The MK43-111-R is used to monitor either 0/4-20 mA or 0/2-10 V input signals. It provides a relay setpoint
output that is adjusted by a potentiometer located on the device front.
Jumpering terminals 2 and 4 programs the signal direction of either setpoint. With jumpers, the relay
de-energizes if the input signal exceeds the setpoint. Without jumpers, the relay de-energizes if the input signal falls below
the setpoint. The 24 VDC device does not provide galvanic isolation between supply voltage and input.
- MK43-111-R/24VDC
- MK43-111-R/115VAC
- MK43-111-R/230VAC
|
 Dual Channel Analog Data Repeater |
The dual-channel MS31-LIU analog data repeater isolates, converts and repeats standard analog signals and
passes them to a user-defined output. The input circuit accepts a standard current input (0/4-20 mA), a standard voltage input
(0/2-10 V) or a variable voltage input (0-1 V to 0-10 V). The transfer characteristics are programmed using jumpers across
terminals 14, 15 and 16. This allows dead-zero signals to be converted to live zero and vice versa. The device also converts
current signals to voltage signals and vice versa.
The analog output signal is available at both outputs, which may be used simultaneously. One output is a
voltage output; the other is a current output. The power supply is galvanically isolated from the input and output circuits.
A green LED provides power "ON" indication. Special version: MS31-LIU ... /M12: signal inverter (0-20 mA inverted to 20-0 mA).
|
 Bistable Switching Amplifiers |
The MS41-22Ex0-R is a single channel device with four intrinsically safe inputs that can be used as a
bistable relay, or as a programmable switching amplifier without bistable characteristics.
As a bistable relay, the switching functions can be programmed to perform "AND" (identity) or "OR"
(exclusive OR) functions (set / reset control). By leaving the inputs open or closed, the desired function may be selected.
The input circuits can be configured for:
- Set-Reset Flip-Flop Control
- Programmable Switching Amplifier
- Exclusive OR Circuit
- Lockout Circuit
- Trigger Circuit
- Sequence Control
- Pump in
- Pump out
|
 Multi-Safe Logic Amplifier Relay |
The MS41-42Ex0-R logic amplifier relay has 4 intrinsically safe inputs that accept
NAMUR Sensors Or Mechanical Contacts. The inputs are combined into a user defined
logic output. The output circuit consists of a DPDT relay. A switch located on the front panel provides a choice of six logic
functions.
For applications requiring less than four inputs, observe the following:
- unused inputs should be left open when selector positions 1 and 2 are used (AND/NAND)
- unused inputs should be jumpered when selector positions 3 and 4 are used
The IDENTITY and NON-IDENTITY functions (selector positions 5 and 6) can only be attained with four input
sources.
|
 Level Control Monitor - Range Selector Switch / Jumpers |
TURCK offers liquid level probes for use in conjunction with our level control monitors, to provide a
simple solution for liquid level applications. The resistance between the terminals is measured to determine the level of the
medium in the tank. The level control logic is built into the controller, which offers a variety of options to fit any
applica tion.
- Adjustable Sensitivity
- Single Set-points
- Multiple Inputs
- On/Off Delay
- Programmable Outputs
|
 Level Control Monitor - Range Selector Fixed |
Range Selector Fixed
- Single Level Controller 10 second delay
- Part Number: MK 91-R11/24VDC
- ID Number: M7525202
- Level Control Monitor with Fixed Switch Point
|
 Level Control Monitor - Range Selector Jumpers |
Range Selector Jumpers
- Dual Level Controller, Adjustable Time Delay
- Part Number: MS91-12-R
- ID Number: M5220110
- Level Control Monitor, Potentiometer/Jumper Programmable
|
|
Our TURCK Logic & Set-Point Controller Distributors warehouse in Boise, Idaho stocks some TURCK products
enabling us to further assist you in finding the correct TURCK Interface Modul Controllers for your application in the USA, Canada
and Mexico. Whether we have TURCK Multi Modul Controllers in stock in Boise, Idaho or need to ship direct from TURCK to any USA
cities; Clearwater Tech can get TURCK Multi-Safe Analog Signal Repeaters to you fast and save you money! It will be very helpful if
you have the TURCK Converters part numbers ready, then our sales representatives can provide you with a pricing and availability
quote for the TURCK Switching Amplifiers that you are looking for in seconds. If you do not have the part numbers for TURCK Rate
Dividers, our application engineers will be able to help you figure out the TURCK part numbers and get the price quote to you as
soon as possible.
|