June 03, 2011
SUNX Switches
The S-Link Series
from Panasonic allows for great wire-saving for all connections. Installation is made easy with no faulty wiring. The power
supply line can also be wired up together enabling true wire-saving for I/O devices. Just with the wire-saving between the
PLC and the sub-stations, you will be able to save a mountain of I/O device connection wires.
|
Banner Fiber Optic Sensors
The D10 Expert
is an easy-to-use, DIN-rail-mountable fiber optic sensor. It provides high performance sensing in low-contrast applications.
Configuration options include SETUP mode plus Static and Dynamic TEACH, and Window SET options, in addition to manual fine
adjustment, remote programming, and security push button lockout. The sensor's compact housing has a large, easy-to-see
bar graph display plus
|
|
|
|
 |
(800) 894-0412 (208) 368-0415 (Fax) info@clrwtr.com |
 Input/Output Stations |
TURCK's Advanced I/O Module (AIM) DeviceNet stations are extremely rugged stations designed for machine
mounting. These stations allow easy connection of standard I/O devices (such as sensors, rotary switches, valves and pilot lights) to a DeviceNet
network, typically without a protective enclosure. This is made possible by epoxy-filled station housings, all-metal connectors
and visible rotary address switches, among other things.
TURCK DeviceNet AIM stations are designed for machine mounting with no separate enclosure or housing
necessary. Quick-disconnect capability, combined with an epoxy-filled housing, creates an extremely durable station that can be
mounted in most industrial environments. DeviceNet AIM stations generally provide connections for the bus and I/O, in addition
to auxiliary power for stations with outputs.
|
|
If you are looking for TURCK DeviceNet Industrial I/O, please call us on
(800) 894 - 0412 or email us at
info@clrwtr.com
we will do our best to help you find the TURCK DeviceNet AIM Stations that you are looking for at competitive prices. If you
are searching for TURCK DeviceNet Output Stations technical information (data-sheets) please use the datasheets or product
selection guide page links.
|
 Gateway for BL20 |
Gateway for BL20 I/O System Interface for DeviceNet
- DIP switch for adjustment of the node address
- Degree of protection IP20
- 2 x end brackets BL20-WEW35/2-SW
- 1 x end plate BL20-ABPL
- With integrated supply
- LEDs for display of supply voltage, common alarm and bus errors
- Interface between BL20 system and DeviceNet
- 125 / 250 / 500 kbps
- The connection to DeviceNet is established via an open-style connector
- BL20-E-GW-DN
|
 E-Connect Systems |
Safely stopping motion is becoming more critical as machinery and systems become more automated. Where
once a machine was controlled by one person, today we have many interconnect machines that are controlled by industrial PCs
and PLCs. Motion may start automatically without warning, and some of today's equipment is almost silent in comparision to
the background noise of the factory. TURCK has developed three systems to quickly connectorize standard E-stop devices.
- Series E-connect
- Series E-connect with bus monitoring and annunciation
- Dedicated E-connect
|
 Masters |
- Electrical
- Bus Power: 11-30 VDC
- Current Consumption: 125 mA (Slave), 30 mA (Master)
- Adjustments
- Slave Side (Network address): 0-63 via rotary switches
- Master Side (Node count): 0-8 via rotary switches
- Master Baud Rage (5,6,7): 5=125 K, 6=250 K, 7=500 K
- Connections
- Housing
- Material: Glass filled nylon with nickel plated brass connectors
- Enclosure: NEMA 1,3,4,12,12 and IEC IP 67, 68 and 69K
- Operating Temperature: -25° to 70° C (-13° to 158° F)
|
 Repeaters |
TURCK REP-DN is a potted, fully connectorized rugged repeater that can be mounted directly on the
machine. It is designed for use on any Controller Area Network (CAN), including DeviceNet. Network segments connected by a
repeater are considered separate physical networks (trunk and drop lengths for each segment are determined as if the other
segments are not there), but one logical network (addresses cannot be duplicated - the scanner and configuration tools work
as a single network).
A repeater does not consume an address and is invisible to all the other devices on the network. A
repeater does not have an EDS file. The REP-DN repeater can be used to extend either the trunk or drop lines, and to isolate
power supplies on networks with multiple supplies. There is no limit to the number of repeaters that can be used on one
network.
|
 Spanners |
- Electrical
- Operating Current: 125 mA from segment A, 30 mA from segment B
- Power Distribution
- Station: DeviceNet power supply for each segment (must be powered by separate supplies)
- Mechanical
- Operating Temperature: -40 to +70°C (-40 to +158°F)
- Protection: NEMA 1,3,4,12,13 and IEC IP 67
- Vibration: 50 g @ 10-500 Hz
- Material
- Connectors: Nickel-plated brass (stainless steel available on request)
- Housing: Nylon 6 (other materials available on request)
- Diagnostics (Physical)
- One LED for each segment to indicate communication status
|
 Enclosure Mounted Stations |
- Electrical
- Operating Current: <75 mA (from DeviceNet) plus I/O currents (from bus power)
- Input Current: <700 mA sum of all inputs (from DeviceNet)
- Output Current: <500 mA per output (from DeviceNet)
- Power Distribution
- Inputs: DeviceNet power supply
- Outputs: DeviceNet power supply
- Diagnostics (Physical)
- LED to indicate status of DeviceNet communication
|
 Piconet Stations |
TURCK's piconet DeviceNet stations are compact rugged stations designed for machine mounting. These
stations allow easy connection of standard I/O devices such as sensors, limit switches, valves and pilot lights to a DeviceNet
network, typically without a protective enclosure. This is made possible by epoxy-filled station housings, all-metal
connectors and visible rotary address switches, among other things. Piconet's small size sets them apart from other stations.
piconet stations are the smallest rugged I/O modules available, with a standard housing footprint of 30 x 175 mm. They are
also available with picofast (M8) Connectors for I/O, making them ideally suited for
small-space applications.
TURCK DeviceNet piconet stations are designed to be mounted directly on machines and work cells with no
separate enclosure or housing necessary. Epoxy-filled housing creates a durable station that allows it to be mounted in most
industrial environments.
|
 OEM Stations |
- PC-Board Slaves
- Small Footprint
- Ideal for Retrofits
- Bus Powered I/O
- Power Distribution
- Inputs: DeviceNet power supply
- Outputs: DeviceNet power supply
- Diagnostics (Physical)
- One bit in I/O table indicates input fault for entire station, one bit er output for fault indication
|
 Gateways |
TURCK's BL67 is a modular, user configurable network I/O system designed to allow installation of nodes
containing different types and sizes of I/O depending on the users needs for a particular area. Featuring IP 67 protection and
Metal Threaded Connectors, the BL67 can often be mounted in the physical process
environment or directly on a machine without the need to plan or purchase a separate enclosure for the I/O. This saves planning
and installation time, as well as the cost of the enclosure itself.
The BL67 system supports several different network protocols, including DeviceNet. A BL67 station consists of
a gateway module that interfaces to the DeviceNet system, and several I/O modules that interface with the physical I/O in the
field. Different connector options are available to allow a greater level of customization to the user.
|
 Cables/Cordsets |
TURCK DeviceNet Cable Specifications
- Cable that Meets the Requirements of ODVA Thin or Type 1/ODVA Mid or Type III/ODVA Thick or Type II Cable
- Commonly Used as Drop Cable to a Maximum Length of 6 Meters (20 Feet) or Trunk Cable in Networks Up to a Maximum Length
of 100 Meters (328 Feet)
- Provides More Flexibility When Used as a Trunk Cable Up to a Maximum Length of 300 Meters (984 Feet)
- It Provides the Most Power to a Network When Used as a Trunk Cable Up to a Maximum Standard Cable Length of 500 Meters
(1640 Feet)
|
 Junctions |
TURCK DeviceNet, minifast Passive Multi-Port Junctions
- Rugged, Fully Encapsulated Enclosure
- For Connecting I/O in Concentrated Areas
- Bus-In / Bus-Out Eliminates Need for Splitter Tee
- Suitable for Outdoor Applications
|
 Conduit Adapters & Tees |
TURCK DeviceNet, Bus Drop and Diagnostic Tees
- Creates a Drop or Branch from the Main Bus Line
- (7/8-16UN) minifast Connectors on Bus and Drop Lines
- Available in Three Keyway Options
|
 Field Wireable Connectors & Receptacles |
TURCK DeviceNet, (M12x1) eurofast Male Receptacles
- Provides Quick Connection to Field Devices
- Available for 1/2-14NPT, 1/2-14NPSM, 3/4-14NPT and M20 Threads
|
Our industrial automation supplies distributors warehouse in Boise, Idaho stocks some TURCK products enabling
us to further assist you in finding the correct TURCK DeviceNet Industrial I/O Piconet Gateways for your application in the USA,
Canada and Mexico. Whether we have TURCK DeviceNet Piconet Stations in stock in Boise, Idaho or need to ship direct from TURCK
to any USA cities; Clearwater Tech can get TURCK DeviceNet Cordsets & Cables to you fast and save you money! It will be very
helpful if you have the TURCK DeviceNet Input Stations part numbers ready, then our sales representatives can provide you with a
pricing and availability quote for TURCK DeviceNet to AS-i Gateways that you are
looking for in seconds. If you do not have the part numbers for TURCK DeviceNet Input/Output Stations, our application engineers
will be able to help you figure out the part numbers and get the price quote to you as soon as possible.
|
|
|
 |
|
| Part Number: |
|
|
Can't find a part number?
E-mail Us! |
|
|