Weidmuller Fieldbus
The FieldbusFoundation
is an open fieldbus standard. It was specially developed for the requirements of process industry technology, including remote
supply and intrinsic safety. Fieldbus Foundation enables users to operate several sensors and actuators on one bus cable. Power
supply to the devices is via a twin cable system with digital transmission of the process data.
|
SUNX Light Curtains
SUNX SF2B Series
has a universal 15ms response time, regardless of the number of channels, the beam axis pitch, or the number
of units connected in series. The result is a simplification of the calculation work involved in setting safety distances
on your machine.
Category 4 Safety Screens
|
|
|
|
 |
(800) 894-0412 (208) 368-0415 (Fax) info@clrwtr.com |
 Power Supply Modules |
TURCK DPC-System (Diagnostic-Power-Conditioner-System) is a power supply system for the installation of Foundation fieldbus
H1 segments. It offers comprehensive diagnostic functions for the monitoring of FOUNDATION fieldbus segments and thus
supporting Asset Management for the whole system. A DPC system consists of one or more module racks DPC-49-MB-RC each with up
to eight power supply modules DPC-49-IPS and one diagnostic module DPC-49-ADU. Up to four H1 segments for each module rack can
be operated and monitored redundantly in the FOUNDATION fieldbus. The diagnostic data from the H1 segments are transmitted via
the HSE interface module DPC-49-HSEFD/24VDC to the higher level Asset-Management-System.
|
|
If you are looking for TURCK FOUNDATION Fieldbus Industrial I/O, please call us on
(800) 894 - 0412 or email us at
info@clrwtr.com
we will do our best to help you find the TURCK FOUNDATION Fieldbus Power Conditioners that you are looking for at competitive
prices. If you are searching for TURCK FOUNDATION Fieldbus Connectors & Receptacles technical information (data-sheets)
please use the datasheets or product selection guide page links.
|
 Cables & Cordsets |
TURCK FOUNDATION fieldbus, Cable Specifications
- Cable that Meets the Requirements of ISA/SP50 and FOUNDATION fieldbus Requirements for Type A Cable
- Cables are Available in 3-wire Versions with a Device Ground or 2-wire Versions
|
 Junction Boxes |
TURCK FOUNDATION fieldbus, minifast Junction Tees
- Indoor Use Only (for outdoor applications use JBBS family)
- Multi-port Junction Provides a Rugged Connection to Network Devices
- Bus-in/Bus-out Feature Eliminates Need for Splitter Tee
- Short-Circuit Protection Available
|
 Connectors & Receptacles |
TURCK FOUNDATION fieldbus, (M12x1) eurofast Female Receptacles
- Mounted for Quick Connection to Enclosures
- Available for 1/2-14NPT, 1/2-14NPSM, 3/4-14NPT and M20 Threads
|
 Junction Box For DIN Rail Mounting |
TURCK introduces JRBS junction bricks for FOUNDATION fieldbus, an innovative product family providing quick
and easy connection of multiple devices to the main fieldbus trunk. JRBS junction bricks are available with 4, 6, 8, 10 or 12
ports and feature removable terminals for simple, efficient installation and wiring modification in tight spaces. These
terminals are located on both sides of the brick to enable easy access for wiring from either direction-and they securely
screw into place-eliminating the risk of becoming disconnected in high vibration environments. Plus, JRBS junction boxes can
be DIN-mounted vertically or horizontally.
|
 Backplane |
Single Segment Redundant Backplane For FOUNDATION Fieldbus H1 Segments
- TURCK Inc. has expanded its Diagnostic Power Conditioner (DPC) system with a Single Segment Redundant Backplane that
can combine two isolated power supply modules into one FOUNDATION fieldbus segment. The new backplane includes an
integrated diagnostic unit used to monitor the redundancy of the external bulk power supply along with the H1 power
supply-aiding in the availability of the H1 segment. System status is available via a relay contact.
- The backplane's small footprint (113mm high by 42mm wide by 210mm long) is designed for DIN rail mounting, and
features separate connections for grounding and shielding. The cable shield may be connected via shield clamps or screw
terminals. Three-Pole Screw Terminals With Flange Connections are
also available to connect the segment outputs.
|
Our industrial automation supplies distributors warehouse in Boise, Idaho stocks some TURCK products enabling
us to further assist you in finding the correct Network Industrial I/O Junctions for your application in the USA, Canada and
Mexico. Whether we have Network Cordsets & Cables in stock in Boise, Idaho or need to ship direct from factory to any USA
cities; Clearwater Tech can get Network Cordsets & Cables to you fast and save you money! It will be very helpful if you have
the TURCK FOUNDATION Fieldbus Devices part numbers ready, then our sales representatives can provide you with a pricing and
availability quote for Network Receptacles that you are looking for in seconds. If you do not have the part numbers for TURCK
Network Junctions, our application engineers will be able to help you figure out the part numbers and get the price quote to you
as soon as possible.
|
|
|
 |
|
| Part Number: |
|
|
Can't find a part number?
E-mail Us! |
|
|