IM33-11Ex-Hi/24 VDC

This 1 channel intrinsically safe interface will power a 2 or 3-wire HART transmitter or a separately powered field device and retransmit the 0/20 mA or 4/20 mA from a hazardous area and repeat the signal in the non-hazardous area as two 0/20 mA or 4/20 mA signals reflecting the hazardous area input. The device will also accept a sourced 0/20 mA or 4/20 mA signal from a separately powered field device and repeat this signal as two non-hazardous area signal. It will drive two separate non-hazardous area loads of up to 500 Ω each.

Due to the "1:1" transmission characteristic, open-circuit or short-circuit conditions can be indicated by a 0 mA or 22.5 mA reading indicating the condition for alarm implementation.

  • 1 channel HART or "IS" compatible analog inputs
  • 2, 3, or 4-wire configurations for sinking or sourcing field devices in any combination
  • 2 independent 0/4-20 mA outputs reflecting a single hazardous area input
  • Constant field voltage
  • Short-circuit protected field circuits
  • Over/under current indication of 0 or 22.5 mA
  • SIL 2 rated
TURCK IM33-11EX-HI/24VDC 1-Channel Ex-HART Isolating Transducers Distributors
IM33-11EX-HI/24VDC

If you are looking for TURCK Analog Input Repeaters, please call us on (800) 894 - 0412 or email us at info@clrwtr.com we will do our best to help you find the TURCK IM33-11Ex-Hi/24 VDC Isolating transducer that you are looking for at competitive prices. If you are searching for TURCK IM33-12Ex-Hi/24 VDC Isolating transducer technical information (data-sheets) please use the datasheets or product selection guide page links.

IM33-12Ex-Hi/24 VDC

This 1 channel intrinsically safe interface will power a 2 or 3-wire HART transmitter or a separately powered field device and retransmit the 0/20 mA or 4/20 mA from a hazardous area and repeat the signal in the non-hazardous area as two 0/20 mA or 4/20 mA signals reflecting the hazardous area input. The device will also accept a sourced 0/20 mA or 4/20 mA signal from a separately powered field device and repeat this signal as two non-hazardous area signal. It will drive two separate non-hazardous area loads of up to 500 Ω each.

Due to the "1:1" transmission characteristic, open-circuit or short-circuit conditions can be indicated by a 0 mA or 22.5 mA reading indicating the condition for alarm implementation.

  • 1 channel HART or "IS" compatible analog inputs
  • 2, 3, or 4-wire configurations for sinking or sourcing field devices in any combination
  • 2 independent 0/4-20 mA outputs reflecting a single hazardous area input
  • Constant field voltage
  • Short-circuit protected field circuits
  • Over/under current indication of 0 or 22.5 mA
  • SIL 2 rated
TURCK IM33-12EX-HI/24VDC 1-Channel Ex-HART Isolating Transducer Distributor
IM33-12Ex-Hi/24VDC

IM33-22Ex-Hi/24 VDC

This 2 channel intrinsically safe interface will power two separate 2 or 3-wire HART Transmitters or separately powered field devices or any combination of these devices and retransmit the 0/20 mA or 4/20 mA from a hazardous area and repeat the signal in the non-hazardous area as two separate 0/20 mA or 4/20 mA signals reflecting the hazardous area input. The device will also accept two separate sourced 0/20 mA or 4/20 mA signals from separately powered field devices and repeat these signals as two non-hazardous area signals. It will drive two separate non hazardous-area loads of up to 500 O each.

Due to the "1:1" transmission characteristic, open circuit or short-circuit conditions can be indicated by a 0 mA or 22.5 mA reading indicating the condition for alarm implementation. HART or conventional "IS" transmitters can be accommodated by this device with bi-directional communications of digital information with HART field devices.

  • 2 independent channel HART or "IS" compatible analog Inputs
  • 2, 3, or 4-wire configurations for sinking or sourcing field devices in any combination
  • Constant field voltage for each channel
  • Short-circuit protected field circuits
  • Over/under current indication of 0 or 22.5 mA
  • SIL 2 rated
TURCK IM33-22EX-HI/24VDC 2-Channel Ex-HART Isolating Transducers Distributors
IM33-22Ex-Hi/24VDC

Our industrial factory automation supplies distributors warehouse in Boise, Idaho stocks some TURCK products enabling us to further assist you in finding the correct TURCK IM33-22Ex-Hi/24 VDC analog input repeaters for your application in the USA, Canada and Mexico. Whether we have TURCK IM33-11Ex-Hi analog input repeater in stock in Boise, Idaho or need to ship direct from TURCK to any USA cities; Clearwater Tech can get TURCK IM33-12Ex-Hi analog input supplies to you fast and save you money! It will be very helpful if you have the TURCK IM33-22Ex-Hi analog input supplies part numbers ready, then our sales representatives can provide you with a pricing and availability quote for the TURCK IM33-11EX-HI/24VDC Ex-HART isolating transducers that you are looking for in seconds. If you do not have the part numbers for TURCK IM33-12EX-HI/24VDC Ex-HART isolating transducer, our application engineers will be able to help you figure out the TURCK part numbers and get the price quote to you as soon as possible.

Stock Check
Part No:
OR
Manufacturer:

Search Tips

Can't find a part number?
E-mail Us.

IDEC E-Stops

The NC Contacts will reliably open, even if they are welded, and stop the machine. This one-of-a-kind "safe break action" design, found only in the IDEC XA and XW series, reverses the energy direction and uses the spring-pressure to assure that the NC contacts will open if the emergency switch is damaged or the contact blocks separate due to excessive force. The XA and XW series of Emergency Stop switches include a revolutionary new

Weidmuller Converter

The MCZ VFC & WAS/WAZ4/5 signal converters can transmit, isolate and convert analogue DC voltages. They are optionally available in widths of 6 mm (MCZ), 12.5 mm (WAS/WAZ4) or 17.5 mm (WAS/WAZ5). The input and output circuits are completely electrically isolated, as is the power supply. The input signal is converted into a DC current/voltage value (WAS/WAZ) or into a proportional frequency (MCZ VFC) between