June 03, 2011
Weidmuller Distributor
The Distributor for PROFIBUS-DP
enables the user to connect it conveniently in the electrical cabinet. They can be mounted on TS32/35 rails and used to
connect standardised PROFIBUS-DP lines. Spur cables can also be connected. Please note that spur cables should be kept short
as possible. Part No. 8788580000 has a 9-pin sub-D socket for connecting analysis/programming devices.
|
Kubler Encoders
The CANopen Device Profiles
describe the functionality of the communication and of that part of the CANopen fieldbus system specific to the manufacturer.
Device Profile 406 applies to encoders and defines the individual objects independently of the manufacturer. In addition the
profile makes provision for additional extended functions specific to the manufacturer; using devices that interface with
CANopen
|
|
|
|
 |
(800) 894-0412 (208) 368-0415 (Fax) info@clrwtr.com |
 Input/Output Stations |
TURCK's Advanced I/O Module (AIM) PROFIBUS stations are extremely rugged stations designed for machine
mounting. These stations allow easy connection of standard I/O devices such as sensors, rotary switch, valves and pilot lights to a PROFIBUS network,
typically without a protective enclosure. This is made possible by epoxy-filled station housings, all-metal connectors and
visible rotary address switches, among other things.
TURCK PROFIBUS AIM stations are designed for machine mounting with no separate enclosure or housing
necessary. Quick-disconnect capability, combined with an epoxy-filled housing, creates an extremely durable station that can
be mounted in most industrial environments.
|
|
If you are looking for TURCK PROFIBUS DP Industrial I/O, please call us on
(800) 894 - 0412 or email us at
info@clrwtr.com
we will do our best to help you find the TURCK PROFIBUS DP AIM Stations that you are looking for at competitive prices. If
you are searching for TURCK PROFIBUS DP Output Stations technical information (data-sheets) please use the datasheets or
product selection guide page links.
|
 Ethernet-PROFIBUS Interface PB-XEPI |
The compact PB-XEPI interface allows easy connection of PROFIBUS networks to Ethernet. It supports a large
number of international open standards on one single hardware platform, including the FDT/DTM standard of excom. The
interface forms the basis for modern field devices and Asset-Management approaches with central configuration, calibration,
diagnosis and Condition-Monitoring.
Because the gateway supports numerous open standards, various configuration tools of leading manufacturers
such as FieldCare (Endress + Hauser), PACTware (PACTware Consortium) or Emerson's AMS Suite can be operated with the same
device platform. The gateway can be integrated into both existing and new systems - independent from process control systems
or SPS manufacturers. The gateway allows fl exible concepts and manufacturer-independent solutions for continuous vertical
integration of production processes. The gateway features one PROFIBUS and one Ethernet interface. The installation width is
merely 23 mm.
|
 Gateway for BL20 |
Gateway for BL20 I/O System Interface for PROFIBUS-DP
- DIP switch rotary for adjustment of the node address
- Degree of protection IP20
- 2 x end brackets BL20-WEW35/2-SW
- 1 x end plate BL20-ABPL
- With integrated supply
- LEDs for display of supply voltage, common alarm and bus errors
- Interface between the BL20 system and PROFIBUS-DPV0/DPV1
- 12 Mbit/s
- Push in clamps
- BL20-E-GW-DP
|
 Repeaters |
TURCK REP-DP repeater serves to assemble two galvanically isolated PROFIBUS-DP segments in RS-485
technology with 32 participants each, and provides IP 67 protection. Up to four repeaters can be connected in series, so that up
to 127 nodes can be operated via a single master; thus PROFIBUS networks can be extended significantly by using repeaters
(depending on the baud rate). The transmission rate is detected automatically (up to 12 Mbaud), and the signals are regenerated
in amplitude. If there are faulty protocols in one of the segments (a wire-break, short-circuit in the bus line or by a
defective node), that segment is decoupled and an error indication is provided by the LED.
Individual PROFIBUS segments are Connected via M12 Connectors. The
repeater is equipped with three female and one male connector; unused connections must be terminated with a terminating
resistor (type: RSSW 45-TR). The shield of the PROFIBUS cable can be grounded directly via a grounding screw (internally the
shield is coupled capacitively with the ground). Power (24 VDC) is supplied via standard 7/8 inch connectors.
|
 Gateways |
TURCK's BL20 is a modular, user configurable network I/O system designed to allow installation of nodes
containing different types and sizes of I/O depending on the users needs for a particular area. Featuring IP 20 protection
and terminal point connections, the BL20 is intended to be mounted in the control cabinet or in a field enclosure. The BL20
system supports several different network protocols, including PROFIBUS-DP. A BL20 station consists of a gateway module that
interfaces to the PROFIBUS system, and several I/O modules that interface with the physical I/O in the field. The terminal
bases are available with tension clamp or screw terminal connector types. TURCK's I/O Assistant software package is used to
configure the BL20 system.
|
 Cables & Cordsets |
TURCK PROFIBUS-DP Cables & Cordsets
- Cable that Meets the Requirements of EN50170-2-2:1996 for Communications Up to 12 Mbaud
- PROFIBUS-DP (M12x1), eurofast Retractile Cordsets are available in 1, 2, 5 Meter Extended Lengths
- Single or Double Ended
|
 Connectors & Receptacles |
TURCK PROFIBUS-DP Field Wireable Connectors & Receptacles
- Provides Connection to Master or Node in the field
- Maximum Cable O.D. is 8.5 mm
- Terminating Resistors
- D9 Connectors
- Provides (M12x1) eurofast Connection to Field Devices
|
Our industrial automation supplies distributors warehouse in Boise, Idaho stocks some TURCK products enabling
us to further assist you in finding the correct TURCK PROFIBUS DP Industrial I/O Gateways for your application in the USA, Canada
and Mexico. Whether we have TURCK PROFIBUS DP Input Stations in stock in Boise, Idaho or need to ship direct from TURCK to any USA
cities; Clearwater Tech can get TURCK PROFIBUS DP Cordsets & Cables to you fast and save you money! It will be very helpful if
you have the TURCK PROFIBUS DP Input Stations part numbers ready, then our sales representatives can provide you with a pricing
and availability quote for TURCK PROFIBUS DP Output Stations that you are looking for in seconds. If you do not have the part
numbers for TURCK PROFIBUS DP Gateways, our application engineers will be able to help you figure out the part numbers and get the
price quote to you as soon as possible.
|
|
|
 |
|
| Part Number: |
|
|
Can't find a part number?