Vacon AC Drives

Although extremely compact in size, the VACON 20 is packed with functionality to help improve system performance and cost efficiency. Fast installation and set-up are possible due to easy-access terminals, integral DIN rail mounting and the parameter copying tool which can clone settings without needing mains power.

Vacon 20 Compact AC Inverters Distributors

20 Series

Complete User Manual

The parameter list can be freely modified and application-specific parameter sets and default settings can be created. PLC functionality means individual control logic can be built into the drive and unused I/O options can be used for other machine-related tasks.

The built-in RS-485 interface provides a cost-effective and simple serial-control interface for the drive. With optional modules, VACON 20 can be connected to almost any fieldbus system based on RS-485 or Ethernet, including Profibus DP, CANOpen, DeviceNet, Profinet I/O, EtherCAT, Modbus TCP/IP and Ethernet IP.

Available in all common voltages and in a wide power range, VACON 20 optimizes the performance of, for example, vertical-movement, packaging, material-handling and flow-control applications in various process industries around the globe.

If you are looking for Vacon 20 Series AC Drives, please call us on (800) 894 - 0412 or email us at info@clrwtr.com we will do our best to help you find the Vacon 20 Compact Drive that you are looking for at competitive prices. If you are searching for VACON0020-1L VFD Inverter technical information (data-sheets) please use the datasheets or product selection guide page links.

Benefits:

  • High functionality and performance
  • Fieldbus support for many systems, including CANOpen, DeviceNet & Profibus
  • Parameter copying without main power
  • Custom-made software available
  • Fast and easy installation and setup

Features:

  • Wide power range up to 18.5 kW/25 HP
  • Available in voltages 110-600V
  • Built-in RS-485 interface for fieldbus control
  • Full I/O + optional board support
  • Built-in choke as option in =16A types
  • Pulse train input
  • Easy user interface
  • Built-in PLC functionality based on IEC61131-3
  • Built-in EMC filter
  • DIN-rail mounting available
AC Drive Type Power Motor Current Frame Size
kW HP IN(A) 1.5xIN(A)
110-120 VAC, 1-Phase (North America Only)
VACON0020-1L-0001-1 0.25 0.33 1.7 2.6 MI2
VACON0020-1L-0002-1 0.37 0.5 2.4 3.6 MI2
VACON0020-1L-0003-1 0.55 0.75 2.8 4.2 MI2
VACON0020-1L-0004-1 0.75 1 3.7 5.6 MI2
VACON0020-1L-0005-1 1.1 1.5 4.8 7.2 MI3
208-240 VAC, 1-Phase
VACON0020-1L-0001-2 0.25 0.33 1.7 2.6 MI1
VACON0020-1L-0002-2 0.37 0.5 2.4 3.6 MI1
VACON0020-1L-0003-2 0.55 0.75 2.8 4.2 MI1
VACON0020-1L-0004-2 0.75 1 3.7 5.6 MI2
VACON0020-1L-0005-2 1.1 1.5 4.8 7.2 MI2
VACON0020-1L-0007-2 1.5 2 7 10.5 MI2
VACON0020-1L-0009-2 2.2 3 9.6 14.4 MI3
208-240 VAC, 3-Phase
VACON0020-3L-0001-2 0.25 0.33 1.7 2.6 MI1
VACON0020-3L-0002-2 0.37 0.5 2.4 3.6 MI1
VACON0020-3L-0003-2 0.55 0.75 2.8 4.2 MI1
VACON0020-3L-0004-2 0.75 1 3.7 5.6 MI2
VACON0020-3L-0005-2 1.1 1.5 4.8 7.2 MI2
VACON0020-3L-0007-2 1.5 2 7 10.5 MI2
VACON0020-3L-0011-2 2.2 3 11 16.5 MI3
VACON0020-3L-0017-2 4 5 17.5 26.3 MI4
VACON0020-3L-0025-2 5.5 7.5 25 37.5 MI4
VACON0020-3L-0031-2 7.5 10 31 46.5 MI5
VACON0020-3L-0038-2 11 15 38 57 MI5
380-480 VAC, 3-Phase
VACON0020-3L-0001-4 0.37 0.5 1.3 2.0 MI1
VACON0020-3L-0002-4 0.55 0.75 1.9 2.9 MI1
VACON0020-3L-0003-4 0.75 1 2.4 3.6 MI1
VACON0020-3L-0004-4 1.1 1.5 3.3 5.0 MI2
VACON0020-3L-0005-4 1.5 2 4.3 6.5 MI2
VACON0020-3L-0006-4 2.2 3 5.6 8.4 MI2
VACON0020-3L-0008-4 3 5 7.6 11.4 MI3
VACON0020-3L-0009-4 13.5 9 6 4 MI3
VACON0020-3L-0012-4 5.5 7.5 12 18.0 MI3
VACON0020-3L-0016-4 7.5 10 16 24 MI4
VACON0020-3L-0023-4 11 15 23 34.5 MI4
VACON0020-3L-0031-4 15 20 31 46.5 MI5
VACON0020-3L-0038-4 18.5 25 38 57 MI5
575 VAC, 3-Phase (North America Only)
VACON0020-3L-0002-7 0.75 1 1.7 2.6 MI3
VACON0020-3L-0003-7 1.5 2 2.7 4.1 MI3
VACON0020-3L-0004-7 2.2 3 3.9 5.9 MI3
VACON0020-3L-0006-7 4 5 6.1 9.2 MI3
VACON0020-3L-0009-7 5.5 7.5 9 13.5 MI3

Our industrial factory automation supplies distributors warehouse in Boise, Idaho USA stocks some Vacon products enabling us to further assist you in finding the correct VACON0020-3L drive in the USA, Mexico and Canada. Whether we have Vacon 20 110-120 VAC drive in stock in Boise, Idaho USA or need to ship direct from Vacon to any USA cities; Clearwater Tech can get Vacon 20 208-240 VAC VFD to you fast and save you some money! It will be very helpful if you have the Vacon single-phase 20 drive part numbers ready, then our sales representatives can provide you with a pricing and availability quote for Vacon three-phase 20 inverter that you are looking for in seconds. If you do not have the part numbers for Vacon 20 208-240 VAC drives, our application engineers will be able to help you figure out the part numbers and get the quote to you as soon as possible.

Stock Check

Part No:
OR
Manufacturer:

Search Tips
Can't find a part number?
E-mail Us!

Fuji Drives

The Chilled Water Pump circulates the chilled water generated with the Refrigeration machine to the air conditioner and fan coil. The pump speed is adjusted optimally according to the header pressure. Moreover, the pump conveyance pressure can be controlled to the proper value by converting the flow rate signal to the target pressure using the linearization function. The speed of supply and return fans is adjusted optimally according to the pressure,

SymCom Monitor

Motor Run Hours, displayed by the Informer-MS can now be reset on the Model 455. The Model 455 three-phase voltage monitor combines load and line-side monitoring to alert the user of contact failure or impending contact failure. The line-side monitoring will protect the motor from damaging line-side conditions prior to the motor starting. With other line/load-side voltage monitors, the motor must be started before a voltage problem is detected.