May 11, 2011
Red Lion Converters
The IAMA0006
can isolate and convert over 35 combinations of analog signal ranges. The IAMA converts and transmits signals linearly
proportional to the input. DIP switch range selection eliminates the need to order and stock different modules for each input and
output signal range, and allows quick and convenient setup for over 35 standard signal conversions.
|
TURCK Couplers
The MK73-R111-Ex0 & MK73-R222-Ex0 Electrical Relays
are used to switch intrinsically safe electrical circuits. They provide reliable galvanic isolation to EN 50020 between
control circuit and contacts. This reed relay has a considerably higher switching frequency (50 Hz) than standard
relays. The Rhodium contacts are also well suited for general control applications,
|
|
|
|
 |
(800) 894-0412 (888) 723-4773 (Fax) info@clrwtr.com |
 Input Loop Powered |
Input Current Loop Supply
- Input-current loop-powered passive isolators: in 6-mm MCZ or in 17.5-mm WAVEBOX housing.
- Passive isolators are used for electrical isolation of standard signals from 0/4 to 20 mA. The input-side-supplied
modules take the power needed for signal transmission and supply from the active input circuit.
- These passive isolators have very low current consumption; they can be used anywhere in the field where no other
suitable power supply is available. These analogue converters are used in a variety of application processes as signal
isolators and signal multipliers. They can be used to eliminate measurement errors caused by differences in earth
potentials.
|
|
If you are looking for Weidmuller DC/DC Passive Isolators, please call us on
(800) 894 - 0412 or email us at
info@clrwtr.com
we will do our best to help you find the Weidmuller Output Current Loop Supply that you are looking for at the most
competitive prices possible. If you are searching for Weidmuller Input/Output Current Disconnectors technical information
(data-sheets) please use the datasheets or product selection guide page links.
|
 Output Loop Powered |
Output Current Loop Supply
- Output-current loop-powered signal isolator/multipliers in two-wire design with analogue DC current input.
- The WAS/WAZ OLP 1- and 2-channel output-current loop-powered passive isolators in 17.5-mm-wide WAVEBOX housings. The
inputs and outputs are electrically isolated. Multiple voltage and current input ranges can be set via DIP switches. The
components are remarkable for their very low current consumption.
- Output-current loop-powered analogue converters are used in a variety of application processes as signal isolators,
signal amplifiers and signal multipliers. They can be used to eliminate measurement errors caused by differences in earth
potentials.
|
 AUX Powered |
One & Two Channel (Miniature) Converters
- 1-and 2-channel analogue signal converter/supply isolators with 2- or 3-way isolation and external power supply: for
monitoring and isolating analogue DC current signals.
- The converters are available in 6.1 mm, 12.5 mm and 17.5 mm widths.
- The input and output channel are completely electrically isolated, as is the power supply.
|
 Feed Isolator |
MICROSERIES - Feed Isolators
- The MAS supply separators are used as the link between sensors and control.
- As a rule, they separate the measuring signal from the sensor and the PLC or DCS.
- The external DC power supply simultaneously supplies the supply isolators and the field sensors.
- The supply isolator is suitable, optionally, for the transmission of the HART protocol.
- Here, a data signal is modulated onto the carrier signal (measuring signal 4 to 20mA) which is used for communication
between sensor and control.
|
 Signal Multiplexers |
Signal Multiplexer/Loop Splitter
- The WAS/WAZ CCC 2OLP is an input and output current loop-fed passive disconnector which separates a 4 to 20 mA
input electrically and converts it into two 4 to 20 mA outputs.
- This loop splitter is built into a compact WAVEBOX enclosure just 17.5 mm wide.
|
 JACKPAC |
Signal Multiplexer/Loop Splitter
- JACKPAC DC/DC passive disconnectors comply with class of protection IP 68 and are suitable for installing directly
on the machine.
- The module can be looped into existing applications directly via M12 connectors.
- Passive isolators are used for electrical isolation of standard signals from 0/4 to 20 mA. The input-side-supplied
modules take the power needed for signal transmission and supply from the active input circuit.
- The device is used for separating earth loops and for eliminating interference from the input side.
|
|
Our industrial factory automation supplies distributors warehouse in Boise, Idaho USA stocks some Weidmuller
products enabling us to further assist you in finding the correct Weidmuller DC/DC Passive Isolators in the USA, Mexico and
Canada. Whether we have Weidmuller JACKPAC Disconnectors in stock in Boise, Idaho USA or need to ship direct from Weidmuller
to any USA cities; Clearwater Tech can get Weidmuller DC/DC Passive Isolators to you fast and save you some money! It will be
very helpful if you have the Weidmueller DC/DC Passive Isolators part numbers ready, then our sales representatives can
provide you with a pricing and availability quote for Weidmuller Input Current Loop Supply that you are looking
for in seconds. If you do not have the part numbers for Weidmuller Output Current Loop Supply, our application engineers will
be able to help you figure out the part numbers and get the quote to you as soon as possible.
|
|
|
|
 |
|
| Part Number: |
|
|
Can't find a part number?
E-mail Us! |
|
|