(800) 894-0412 (888) 723-4773 (Fax) info@clrwtr.com |
 AUX Powered |
One & Two Channel (Miniature) Converters
- One- and two-channel analogue signal converter/ supply isolator with external power supply: for isolating and
transmitting analogue voltage signals; one- and two-channel output-current loop-powered signal isolator/multiplier in
two-wire design with analogue voltage input. The converters feature optional IP20 or IP6X protection and can thus be
used in a many different environments. The input and output channel are completely electrically isolated, as is the power
supply.
|
|
If you are looking for Weidmuller Measuring Transducer, please call us on
(800) 894 - 0412 or email us at
info@clrwtr.com
we will do our best to help you find the Weidmuller DC/DC Converter that you are looking for at the most competitive prices
possible. If you are searching for Weidmuller Isolation Amplifier technical information (data-sheets) please use the
datasheets or product selection guide page links.
|
 Single & 2 Channel |
Single-Channel (Miniature) & 2-Channel
- Single-channel & Dual-Channel input current loop-fed passive disconnector in a WAVEBOX enclosure just 17.5 mm wide.
The inputs and outputs are electrically isolated. The passive disconnectors are characterised by their low current consumption.
|
 Current - Input/Output Loop & AUX Powered |
- Output-current loop-powered signal isolator/multiplier in two-wire design with analogue DC current input.
- 1- and 2-channel isolation amplifier from the TWI series
- 1- and 2-channel passive isolator WAS/ WAZ OLP
- Input-current loop-powered passive isolator:
- 1- and 2-channel passive isolator in a 6-mm MCZ housing
- 1- and 2-channel passive isolator in a 17.5-mm WAVEBOX housing
- 1- and 2-channel passive isolator in a IP6X JACKPAC housing
- 1-and 2-channel analogue signal converter/supply isolator with 2- or 3-way isolation and external power supply:
- IP20 protection with widths of 6.1 mm (MCZ- and MICROSERIES), 12.5 mm, 17.5 mm (WAVESERIES) and
46mm (MANNSERIES - Australia)
- IP6X-protection JACKPAC active and passive isolator
|
 Universal |
Universal Signal Converter & Trip Amplifier
- ITX Plus: universal, output-current loop-powered signal isolator/converter in two-wire design: for measuring analogue
DC voltage, DC current and temperature.
- WAVE TTA: universal signal converter and trip amplifier: configurable with PC. Combines the functions of isolation,
transmission, linearization and trip amplification in a single module. These exceptional characteristics and outstanding
configurability combine to make the TTA truly unique. The TTA functions with stability and precision under a wide range
of voltages and ambient temperatures. It is compatible with all standard sensor types.
|
 Thermocouple |
Thermal signal converter with external supply voltage. Input and output parameters can be universally
configured and parameterized. Integrated features include cold-junction compensation and linearization of the sensor
signals.
Standard thermal elements can be connected on the input side, in accordance with IEC 564. Depending on
their housing type, these converters are available in widths of 6.1 mm and 17.5 mm. They can be used in the electrical
cabinet for any process automation and industrial automation applications.
|
 Resistance Temperature Device (RTD) |
Single-channel, output-current loop-powered RTD signal converter in 6-mm-wide MCZ housing and RTD
converter with external power supply.
- Output Loop Powered
- AUX Powered
|
 Frequency |
Universal, electrically-isolated signal converters for measuring frequencies with auxiliary power supply
and optional limit-value monitoring. The WAS/WAZ PRO Freq f/DC converter in its compact WAVEBOX housing is just 12.5 mm wide.
It converts input frequencies of up to 100 kHz into standardized analogue signals. This component can be configured as
required via DIP switches.
The connection on the input side is suitable for both 2- and 3-wire PNP/NPN or Namur initiators. The
component has 4 kV 3-way isolation and does not have to be calibrated separately.
|
 Strain Gauge (Bridge) |
Bridge measurement isolator/converter with auxiliary power supply: converts signals from a Wheatstone
bridge into standardised analogue values. Typical applications include force, weight and torsion measurements. The ACT20P
bridge converts bridge measurement signals into standard signals. A push button is used to adjust to the load cells. The
ACT20P product line offers customers precise and functional signal conversion in a compact design. It supplies bridges with
up to 4 x 350 O at 10 V. The ACT20P bridge supports easy tare weight calibration by using an input for an external button or
a PLC output.
The PRO BRIDGE comes in a compact 17.5-mm WAVEBOX housing and has complete 3-way isolation. It can be
programmed as required via DIP switches. A change in the resistance of the measuring bridge is detected immediately and
imported.
|
 Current Monitoring |
Current AC
- AC or AC/DC current monitoring components with analogue output.
- Depending on the version, the input side can be used to measure single-phase AC currents up to 60 A.
- The output side features switchable analogue DC current/voltage signals.
- Measuring transducer for AC currents up to 500 A, for mounting on TS35 rail.
- Suitable for feeding though conductors with diameters up to 35 mm.
|
 Voltage Monitoring |
Voltage AC - AUX Powered
- Universal single-phase AC voltage monitoring components with analogue output and external power supply.
- On the input side these components feature multiple ranges for measuring voltages up to 450 V AC.
- The output signal is available optionally as current loop or analogue DC voltage.
- The input/output and the separate 24-VDC supply are electrically isolated with 4 kV.
|
 DC/DC 2-Way Isolator |
DC/DC 2-Way Isolator
- A 2-way isolation separates the signals electrically and decouples the measuring circuits.
- Potential differences caused by long lines and common reference points are eliminated.
- Moreover, the electrical isolation protects against damage caused by overvoltages as well as inductive and
capacitive couplings.
|
|
Our industrial factory automation supplies distributors warehouse in Boise, Idaho USA stocks some Weidmueller
products enabling us to further assist you in finding the correct Weidmuller Thermocouple Converter in the USA, Mexico and
Canada. Whether we have Weidmuller Resistance Temperature Device RTD in stock in Boise, Idaho USA or need to ship direct from
Weidmueller to any USA cities; Clearwater Tech can get Weidmuller Strain Gauge (Bridge) Transmitter to you fast and save you
some money! It will be very helpful if you have the Weidmuller Frequency Isolator part numbers ready, then our sales
representatives can provide you with a pricing and availability quote for Weidmuller Bridge Measuring Transducer that you are
looking for in seconds. If you do not have the part numbers for Weidmuller Frequency Converter, our application engineers
will be able to help you figure out the part numbers and get the quote to you as soon as possible.
|