May 11, 2011
NK Switches
AS1 Series Current Operated Switches
combine a current transformer, signal conditioner and limit alarm into a single package for use in status monitoring or proof
of operation applications. Offering an extended set point range of 1-150A and universal, solid-state outputs, the self-powered
AS1 can be tailored to provide accurate and dependable digital indication of over-current conditions across a broad range of
applications.
|
SSAC Obstruction Lamp Alarm Relay
The SCR490D Series
is used to provide remote monitoring of steady burning incandescent marker and obstruction lighting. Four onboard switches
allow operator programming for lighting systems with two through nine lamps on a single AC circuit. The SCR490D uses a
toroidal sensor and electronic circuitry to sense the failure of one or more lamps. When a lamp fails, the SCR490D senses a
decrease in current flow.
|
|
|
|
 |
(800) 894-0412 (888) 723-4773 (Fax) info@clrwtr.com |
 Micromann AR Series |
The AR series of signal isolating converters, with alarm function for process automation, provide a
flexible interface between the sensor and the control system. The output side features analogue standard signals and two
relay outputs for limit monitoring. On the input side, parameters can be processed depending on the module.
This includes signal isolating converters for processing analogue signals such as current, voltage,
temperature (PT100 & Thermocouple Sensors),
frequency, conductivity, curve linearization/characterization, and additional math functions. The process monitoring
components from the AR series come with a four-character, scalable LED display. The scaling of the input parameters is done
automatically. External passive sensors can be supplied directly via the input circuit of the signal isolating converter. The
user-friendly menus are easy and navigate and make it easy to configure the operating parameters.
|
|
If you are looking for Weidmuller Process Monitoring Modules, please call us on
(800) 894 - 0412 or email us at
info@clrwtr.com
we will do our best to help you find the Weidmuller DPA Series Relay Output Modules that you are looking for at the most
competitive prices possible. If you are searching for Weidmuller Micromann R-Series Process Monitoring Module technical
information (data-sheets) please use the datasheets or product selection guide page links.
|
 Micromann UPI Series |
The frequency isolating transformers with alarm function from the UPI series convert standard analogue
current and voltage signals into a proportional frequency. Measurement errors (which can occur with low input frequencies)
are eliminated with a programmable frequency suppression. In addition, a quadratic function linearizes the signals. External
passive sensors can be supplied directly via the analogue frequency isolating transformer.
An alarm output is available for monitoring the input signal. The four-character LED display can be set
universally. The corresponding scaling for the input parameters is then carried out automatically. The user-friendly menus
are easy and navigate and make it easy to configure the operating parameters. Specific parameters can be selected and changed
using the keyboard and display.
|
 Micromann R Series |
The limit-value monitoring modules from the R series feature two relay contacts on the output side for the
alarm function. Each product version is designed for a defined type of signal and sensor. These include analogue signals such
as current, voltage, temperature (thermocouple and PT100 sensors), frequency and conductivity. Monitoring components with
temperature measurement inputs are equipped with wire break detection mechanisms.
They come standard with programmable functions for setpoint, deadband, high/low-trip switching behaviour,
coil energizing and a variable timer delay on each channel. The XFAR (U/I input) features extra extensions to the standard
functions. This includes an optional alarm function which can be configured in connection with various input parameters, such
as a change in the signal frequency, a signal loss or for individual signal formats. The XFAR is equipped with two alarm
outputs for more complex applications.
|
 DPA Series |
Modules in the DPA Series are used for monitoring limit values. They can be configured for a wide variety
of industrial signals and feature two relay contacts for the alarm function on the output side. A potentiometer on the front
side is used to custom adjust the setpoints and deadbands. The deadband reduces chatter from the alarm relay during switching
operations. The reset point of the alarm contact is individually adjusted away from the hystereses (setpoint).
In order to generate an alarm in the event of a power outage, you should select the "energized" operational
status for one or both of the output relays. A high/low-trip switching behaviour can also be set independently for each
channel. The following analogue input signals can be processed with the current DPA series: temperature (thermocouple and
PT100 temperature sensors), AC/DC currents and voltages, measuring wire and potentiometer positions, resistances,
differential currents and differential resistances.
|
|
Our industrial factory automation supplies distributors warehouse in Boise, Idaho USA stocks some
Weidmuller products enabling us to further assist you in finding the correct Weidmuller DPA Series Relay Output 2-Channel
Modules in the USA, Mexico and Canada. Whether we have Weidmuller Micromann AR Series in stock in Boise, Idaho USA or need to
ship direct from Weidmuller to any USA cities; Clearwater Tech can get Weidmuller Micromann R Series Universal, Relay Output
Modules to you fast and save you some money! It will be very helpful if you have the Weidmuller Process Alarm part numbers
ready, then our sales representatives can provide you with a pricing and availability quote for Weidmuller Micromann DPA
Series Modules that you are looking for in seconds. If you do not have the part numbers for Weidmuller Micromann UPI-Series,
our application engineers will be able to help you figure out the part numbers and get the quote to you as soon as
possible.
|
|
|
|
 |
|
| Part Number: |
|
|
Can't find a part number?
E-mail Us! |
|
|