Protecting Paintings and Other Hanging Art Objects

Protecting Paintings and Other Hanging Art ObjectsPaintings and other hanging works of art can be protected with surface or recessed-mount wide gap switches.
Read More

Control Switching Using DPDT Switches

Control Switching Using DPDT SwitchesThis information describes how to achieve dual switching with one magnetic contact and one magnet. DPDT magnetic contacts such as the Sentrol 1087D, 1084D, 2507AD, or 2707AD (see catalog) may be used in place of two contacts or one contact and a floor mat for an annunciator panel.
Read More

Increasing Gap Distance of Recessed Switch with Second Magnet

Increasing Gap Distance of Recessed Switch With Second MagnetYou can increase the gap distance of a recessed switch in a door about 40% by placing two magnets side-by-side. This is helpful if you need to increase the gap distance but do not have a wide gap switch.
Read More

Mounting Data for Steel Doors and Windows

Mounting Data for Steel Doors and WindowsEach sample was selected at random from finished goods inventory. Tests on each contact were run to measure pull in (make), and drop out (break) distances prior to mounting on the 6" wide, 16" long, and 1/2" thick steel plate.
Read More

Mounting Positions for Recessed Switches

Mounting Positions for Recessed SwitchesSentrol recessed contacts can be installed in a variety of positions to accommodate any application. As shown in Figure 1, the switch and magnet can be mounted end-to-end within an imaginary arc around the switch, or parallel to the switch.
Read More

Protecting A Freezer Door

Protecting A Freezer DoorSecuring a freezer door against unauthorized entry. The Sentrol normally closed 2505A-L5 industrial magnetic contact can withstand condensation or temperatures in freezers down to -40˚F.
Read More

Protecting Art Objects

Protecting Art ObjectsArt objects such as statuary, vases, chests, or other works of art not in cabinets or other coverings, can be protected with the Sentrol roller magnetic switch.
Read More

Protecting Boats At Moorages

Protecting Boats At MooragesUse a Sentrol 2105A standard-type Magnapull to extend coverage of a normal marine alarm to the dock or moorage where the boat is secured.
Read More

Protecting Boats - Deck and Cabin Protection

Protecting Boats Deck and Cabin ProtectionThe interior of a boat can be protected with a magnetic contact in a simple alarm system. Protecting the hatches and companionway can be easily accomplished using recessed or small surface mount switches.
Read More

Protecting Casement Windows

Protecting Casement WindowsUsing surface mount contacts, the switch and magnet are both concealed when the window is closed. Use off-white, white or mahogany brown units to match plastic cover on the window.
Read More

Protecting Chain-Link Rolling Gates

Protecting Chain-Link Rolling GatesFor most chain-link rolling gates, there is considerable tolerance and leeway in the "closed" position. This makes it difficult to assure proper alignment of the gate switch for alarm protection.
Read More

Protecting Deeply Recessed Doors

Protecting Deeply Recessed DoorsFive methods are presented here for protecting deeply recessed doors with surface mount contacts. Note that when mounting on steel, a spacer should be used behind the switch, and/or a wide gap switch should be used.
Read More

Protecting Doors and Windows with Uneven Wiring Holes

Protecting Doors and Windows with Uneven Wiring HolesIt may happen, during installation, that holes are over-drilled, under-drilled, or have an uneven diameter. Oversized holes can occur due to difficulties in drilling, especially in tight quarters or enclosed spaces.
Read More

Protecting Double Hung Windows

Protecting Double Hung WindowsProtecting double hung windows with recessed or surface-mounted magnetic contacts with regular or wide gap switches.
Read More

Protecting Guns and Gun Cabinets

Protecting Guns and Gun CabinetsGun cabinets can be protected like china cabinets on the previous two pages. However, since the glass front to a gun cabinet could be broken, and guns stolen without sounding the alarm, two other methods for protecting guns are provided here.
Read More

Protecting Movable Objects Protecting A China Cabinet

Protecting Movable Objects Protecting A China CabinetValuable china and other collectibles can be protected by arming a china cabinet with either recessed or surface mount magnetic contacts.
Read More

Protecting Movable Objects Protecting A Valuables Drawer

Protecting Movable Objects Protecting A Valuables DrawerValuable coin collections, silverware and jewelry can be protected by arming a storage drawer with either recessed or surface mount magnetic contacts.
Read More

Protecting Office Equipment, Computers, Stereos, TVs and VCRs

Protecting Office Equipment, Computers, Stereos, TVs and VCRsA Sentrol Magnapull switch such as the 1005 can be used to protect a single item. Use epoxy or screws (if appropriate for item case) to mount housing receptacle to item to be protected.
Read More

Protecting Other Fence Gates

Protecting Other Fence GatesOther chain link fence gates can be protected with magnetic contacts. Brackets attach to gate post and gate frame, depending on diameter of post and gate. Switch or magnet may be mounted on inside, outside or side of bracket, depending on space between post and gate.
Read More

Protecting Overhead or Curtain Doors

Protecting Overhead or Curtain DoorsThe 2515A is equipped with the unique Maxi-Gap feature that allows a vertical gap distance of 6" and an overall side-to-side gap of 6". Use for installing security switch on channel of overhead doors that do not line up properly, sag, or that are loose and move with wind or vibration.
Read More

Carbon Monoxide Detector

Carbon Monoxide DetectorThe next generation SafeAir 250-CO carbon monoxide (CO) detector is an accurate and reliable means of alerting building occupants of potentially dangerous levels of CO in the protected area. The internal electro-chemical sensor communicates with a sophisticated on-board microprocessor that accurately tracks CO levels over time.
Read More

Conventional Initiating Devices

Conventional Initiating DevicesEdwards brand 500 Series two-wire conventional photoelectric smoke detectors bring together trusted technology and a full line of features that meet the demands of every type of application. The 500 offers sounder models in two-wire applications, specifically to meet residential occupancy code requirements.
Read More

Hazardous Location Signaling

Hazardous Location SignalingChoose Edwards signals to alert, warn and communicate, and you get solutions designed for safety first - because safety is the heart and soul of everything we make and do. With the industry’s broadest line, we have the proven products that can help make your hazardous locations a bit less hazardous. Trust your hazardous location signaling to the life safety leader.
Read More

Intelligent Addressable Control Panels

Intelligent Addressable Control PanelsThe Edwards family of intelligent components also offers contractors and installers simple setup and installation, while delivering options that take full advantage of intelligent fire alarm processing. With a microprocessor in each device, intelligence is distributed throughout the system so that command decisions are made at the individual module, rather than bottlenecking at the control panel.
Read More

Intelligent Control

Intelligent ControlEdwards life safety systems are a powerful intelligent solution for small to mid-sized buildings. The Edwards family includes intelligent addressable and conventional fire alarm control systems. A full line of remote annunciators, modules and accessories are available for both intelligent/addressable and conventional panels.
Read More

KIR Detectors Take Your FX Installations To The Next Level

KIR Detectors Take Your FX Installations To The Next LevelNew Kidde KIR Series detectors represent the next generation of detection technology with features that mesh seamlessly with Kidde FX fire alarm systems. These high-performance smoke and heat detectors offer innovations designed to ensure that they will suit the application, remain accurate, and stay fully-functional throughout their service life.
Read More

Millenium Event Driver Interface

Millenium Event Driver InterfaceThe windows-based MEDI software package provides command and control of remote signaling devices throughout your facility. With a few simple clicks, you can program MEDI to automatically signal work start and stop times, break times, or any other timed event. You can also manually command MEDI to initiate tones, wav files, or real-time voice. Any time. It integrates with either conventional or RS485 signaling components.
Read More

Millennium System Master

Millennium System MasterGet multi-function power and true flexibility for both emergency and routine signaling. With a single Millennium System Master you take complete control of all your emergency, evacuation, and routine signaling. And you do it with functionality and features that can turn plant-floor signaling into a powerful business tool.
Read More

Remote Annunciation

Remote AnnunciationR-Series Annunciators are high-performance remote annunciators that provide status indication and common controls for Edwards Intelligent Addressable fire alarm systems. This family of annunciators offers LCD or LED annunciation as well as a graphic annunciator driver. Models are available with and without common controls.
Read More

System Master Voice Notification

System Master Voice NotificationThere is a tremendous need for integrated and supervised emergency evacuation and fire systems. Oversight agencies realize this and have either made or are making code changes. In fact, the Occupational Safety and Health Administration (OSHA) has drafted a regulation specifically to address a facility’s emergency action plan and to allow safe escape of employees from the workplace (OSHA Regulation 1910.165).
Read More

Adaptatone Millennium

Adaptatone MillenniumAdaptatone Millennium multiple-tone electronic signals offer the widest selection of tones in the industry. With short code blasts or sustained warning signals, they meet virtually every application requirement from emergency evacuation to routine communications.
Read More

Key Operated Manual Station

The 1534-1 fire alarm key operated station is no longer available and has been replaced with the RMS-1T-KO.
Read More