fuji faq

How Do I Set Up To Operate At The Same Time As Turning On The Power?

Fuji 3/19/2018
How Do I Set Up To Operate At The Same Time As Turning On The Power?F02 (Operation / operation) 1 (External signal (digital input)) and short-circuit the terminal [FWD] and the terminal [CM] (in case of forward rotation).

Setting method

How Do I Set Up To Operate At The Same Time As Turning On The Power?

Short circuit area and terminal specification

How Do I Set Up To Operate At The Same Time As Turning On The Power?

Notes

Frequent opening and closing by the electromagnetic contactor on the input side (primary side) may cause inverter failure. When frequent operation / stoppage is necessary, please do by signal of control circuit terminal "FWD", "REV", or key on touch panel.
Also, please keep frequent opening and closing to within once every 30 minutes in the short term. If you want to secure the life of the inverter for more than 10 years, keep it within once per hour.

One Point Advice

F02 cannot change
1. Change to the state where terminal [FWD] or terminal [REV] and terminal [CM] are not short-circuited.
2. Make sure that the data protection setting is not on (F00 To 0). Please set it.